3M™ Dynatel™ Advanced Modular System 965AMS
Measurement Functions
Ohms Measurements>
Soak Test
1.
Take an initial resistance
measurement by pressing
the
Snap Shot
key.
2.
You will compare this to
other active measurements
to determine the source of
the fault.
3.
One of the properties of
moisture in a circuit is the
current from the ohmmeter
can “dry out” the moisture.
The ohmmeter will first
show a lower resistance,
then after one or two
minutes, the resistance will
increase to a higher reading.
This indicates the fault is
caused by moisture.
Note: This is not an
acceptable procedure to
“dry” a fault.
Initial Reading
Reading After 1 or 2 Minutes