background image

6

C

NANO-LOK

 

4

 

NANO-LOK

Содержание DBI-SALA Nano-Lok XL Series

Страница 1: ... p p 20 ft 6 1 m 310 lbs 140 kg 420 lbs 190 kg 3103866 3 p p 20 ft 6 1 m 310 lbs 140 kg 420 lbs 190 kg 3103872 3 p p 20 ft 6 1 m 310 lbs 140 kg 420 lbs 190 kg 3103873 3 p p 20 ft 6 1 m 310 lbs 140 kg 420 lbs 190 kg 3101684 1 p p p 11 ft 3 35 m 310 lbs 140 kg 420 lbs 190 kg 3501694 2 p p 15 ft 4 57 m 310 lbs 140 kg 420 lbs 190 kg 3501695 2 p p 15 ft 4 57 m 310 lbs 140 kg 420 lbs 190 kg 1 2 3 4 5 6 ...

Страница 2: ...2 2 3 A B FC FF DD SF FC FF DD SF C FC H 1 3 2 A B C D E A B E D C E D C A B ...

Страница 3: ...m 4 5 ft 1 4 m 6 6 ft 2 0 m 8 2 ft 2 5 m 20 ft 6 1 m 0 ft 0m 5 5 ft 1 7 m 8 ft 2 4 m 9 9 ft 3 0 m 25 ft 7 6 m 0 ft 0m 6 4 ft 1 9 m 9 1 ft 2 8 m 11 3 ft 3 4 m C AF Cable SRD 130 310 lbs 59 140 kg B 6 ft 1 8 m 6 ft 1 8 m 7 ft 2 1 m 8 ft 2 4 m 9 ft 2 7 m A 8 ft 2 4 m 0 ft 0m 2 5 ft 0 8 m 3 8 ft 1 2 m 4 9 ft 1 5 m 10 ft 3 m 0 ft 0m 3 1 ft 0 9 m 4 6 ft 1 4 m 5 9 ft 1 8 m 15 ft 4 6 m 0 ft 0m 4 4 ft 1 3 ...

Страница 4: ...4 7 8 9 XXXXXXXXXXX 3M CSID XXXXXXXXXXX 3M CSID XXXXXXXXXXX 3M CSID XXXXXXXXXXX 3M CSID A B ...

Страница 5: ...5 10 11 12 13 14 NANO LOK B B A B C D D C B A A B 15 A NANO LOK ARC FLASH 4 NANO LOK ARC FLASH B NANO LOK 4 A NANO LOK B A D C ...

Страница 6: ...6 C NANO LOK 4 NANO LOK ...

Страница 7: ... the SRD Avoid sudden or quick movements during normal work operation This may cause the device to lock up Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent and ...

Страница 8: ...ial Cover Material Stitching Material Arc Flash SRDs Polyester Vectron Kevlar Nomex Cotton and Protex Kevlar Thread Web SRDs Polyester Vectron Rubber Polyester Nylon Thread Cable SRDs Polyester Vectron Vinyl Polyester Nylon Thread Connector Specifications Figure 1 Reference Model Number Description Material Gate Opening Gate Strength 1 2000025 Carabiner Aluminum 3 4 in 19 mm 3 600 lbs 16 kN 2 2000...

Страница 9: ...r path is required to assure positive locking of the SRD Free Fall Properly using an SRD in overhead applications will minimize free fall distance To prevent an increased free fall distance follow the instructions below Never clamp knot or otherwise prevent the lifeline from retracting or staying taut Avoid any slack in the lifeline of the SRD Do not work above the level of your anchorage Do not l...

Страница 10: ...unintentionally disengage see Figure 5 Connectors must be compatible in size shape and strength Self locking snap hooks and carabiners are required If the connecting element to which a snap hook or carabiner attaches is undersized or irregular in shape a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner A This force may cause the gate to o...

Страница 11: ...The anchorage must meet the anchorage strength requirements stated in Section 1 Follow the manufacturer s instructions supplied with each system component 4 5 OPERATION Prior to use inspect the SRD per the inspection procedure of Table 3 During use connect the SRD to a suitable anchorage or anchorage connector as previously described Connect the Self Locking Snap Hook on the end of the lifeline to...

Страница 12: ...housing causing a potential free fall hazard 6 2 SERVICE SRDs are not repairable If the SRD has been subjected to fall force or inspection reveals an unsafe or defective condition remove the SRD from service and discard see Disposal 6 3 STORAGE TRANSPORT Store and transport SRDs in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Thoroughly inspect th...

Страница 13: ...nce and Locking Buttons and Locking Pins should function correctly Web Lifeline Figure 12 Inspect webbing material must be free of cuts A frays B or broken fibers Check for tears abrasions heavy soiling C mold burns D or discoloration Inspect stitching Check for pulled or cut stitches Broken stitches may be an indication that the device has been impact loaded and must be removed from service Wire ...

Страница 14: ...on Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved By Date Corrective Action Maintenance Approved ...

Страница 15: ......

Страница 16: ... 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC U S PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS...