DONNING AND FITTING THE ExOFIT NEx FULL BODY HARNESS:
Figure 14 illustrates donning and fitting of the
ExoFit Nex Full Body Harness. Prior to each use, inspect the harness per the checklist on the
“Inspection and Maintenance
Log (Table 1)”
. To don and fit the harness:
;
Procedures for buckling and adjusting the straps on you ExoFit Nex Harness will vary with the harness model. See
Sections 3.3 thru 3.4 and Figures 9 thru 10 for details.
1. Lift up and hold the harness by the back Dorsal D-Ring. Ensure the straps are not twisted.
2. Grasp the Shoulder Straps and slip the harness onto one arm. The Dorsal D-Ring will be located on your back side.
Ensure that the straps are not tangled and hang freely. Slip your free arm into the harness and position the Shoulder
Straps on top of your shoulders. The Chest Strap and Chest Buckle will be positioned on the front side when worn
properly.
3. Reach between your legs and grasp the Leg Strap on your right side. Bring the strap up between your legs; buckle to
the mating receptor on you right hip, and adjust the Leg Strap for a snug comfortable fit (see Section 3.3 for buckle
operation). When properly adjusted, tuck the loose end of the Leg Strap under the Strap Keeper.
Repeat this process to buckle and adjust the left Leg Strap.
4. Adjust and buckle the Waist Belt (if applicable).
5. Buckle and adjust the Chest Strap (see Section 3.3 for buckle operation). The Chest Strap should be 15 cm (6 in.)
down from the to of your shoulders. When properly adjusted, tuck the loose end of the Chest Strap under the Strap
Keeper.
6. Adjust the Shoulder Straps for a Snug Fit with the Torso Adjusters (see Section 3.4 for Torso Adjuster operation). Left
and right sides of Shoulder Straps should be adjusted to the same length and the Chest Strap should be centered on
your lower chest, 15 cm (6 in.) down from the shoulders. The back Dorsal D-Ring should be centered between your
Shoulder Blades. The front Sternal D-Ring, if present, should be located laterally within 51mm (2 in.) of the vertical
centerline of the harness (see Section 3.6 for Store-Away D-Ring adjustment).
3.7
USE OF FALL ARREST D-RING OR ATTACHMENT ELEMENT:
For Fall Arrest applications connect to the Dorsal
D-ring or attachment element on your back, between your shoulder blades. Side D-rings, if present, are for Positioning or
Restraint applications only. Shoulder attachments are for Rescue or Retrieval applications only. The front Sternal D-ring is
for Ladder Climbing or Positioning. D-rings on a Suspension Seat are for Suspension or Positioning applications only. (See
Section 1.1.).
3.8
MAKING CONNECTIONS:
When using a hook to connect to an anchorage or when coupling components of the system
together, ensure roll-out cannot occur. Roll-out occurs when interference between the hook and mating connector causes
the hook gate to unintentionally open and release. Self-locking snap hooks and carabiners should be used to reduce the
possibility of roll-out. Do not use hooks or connectors that will not completely close over the attachment object. See
subsystem manufacturer’s instructions for more information on making connections.
3.9
CONNECTING SYSTEM COMPONENTS:
After fitting the ExoFit Nex Harness the user may then connect to other
system components. Follow the guidelines in Section 2 and the manufacturer’s instructions included with the component.
When connecting a system component to the dorsal, or other non visible attachment, the connection should be inspected
by another person to ensure a proper connection has been made and the connector’s gate has closed correctly.
Alternatively, where suitable, the system components may be connected prior to donning the harness.
3.10 SUSPENSION TRAUMA STRAP:
The ExoFit Nex Full Body Harness is equipped with Suspension Trauma Straps (Figure
12) to help prolong allowable suspension time in the event of a fall from height. They should only be used in situations
where a fall has occurred or for training. To use the Suspension Trauma Straps:
1. Unzip the Trauma Strap Pouch on each hip of the harness and deploy the Suspension Straps (Figure 12A).
2. Raise the ends of the straps to access the hook and loops. Insert the hook into the loop that provides the desired
strap length.
3. Lower the Suspension Strap and step onto the strap to alleviate pressure of the harness leg straps on the legs (Figure
12B). Adjust the hook/loop combination for optimal comfort.
;
Maintain an upright position following suspension. Do not lay down. Seek medical attention following a suspension.
4.0 INSPECTION
4.1
RFID TAG:
The Radio Frequency Identification (RFID) tag on the ExoFit Nex Harness (see Figure 13) can be used in
conjunction with a handheld reading device and the web based portal to simplify inspection and inventory control and
provide records for your fall protection equipment.
4.2
INSPECTION FREQUENCY:
The ExoFit Nex Full Body Harness must be inspected at the intervals defined in Section 2.2.
Inspection procedures are described on the
“Inspection and Maintenance Log” (Table 1)
.
4.3 DEFECTS:
If inspection reveals a defective condition, remove unit from service immediately and destroy.
4.4
PRODUCT LIFE:
The functional life of ExoFit Nex Harnesses is determined by work conditions and maintenance. As long
as the product passes inspection criteria, it may remain in service for up to 10 years from the date of manufacture.
Содержание DBI SALA ExoFit Nex 603XS1020
Страница 4: ...4 2 A B C D E F 3 4 C B A FC B C FC 5 6 A B C D E F G A B C 7 A B C...
Страница 5: ...5 8 9 CLICK CONNECT TIGHTEN LOOSEN RELEASE 1 1 1 2 A B C...
Страница 6: ...6 9 3 A 3 B 3 C 3 D 3 E...
Страница 7: ...7 10 1 A B 3 2 A B...
Страница 8: ...8 11 A B C D E...
Страница 9: ...9 12 13 A B 14 1 2 3 4 5 6...