background image

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the Aqua-Pure

®

 CS/CSM Series Resi-

dential Water Softener. Retain these instructions for future reference.  Failure to follow installation, operation and maintenance instructions may result in 
property damage and will void warranty.

Intended use:

The 

Aqua-Pure

 

CS/CSM Series Residential Water Softeners are intended for use in softening water in homes and have not been evaluated for other uses.  

These systems must be installed indoors near the point of entry of a home water line, and be installed by qualifi ed professional installers according to these 
installation instructions.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

 WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.

 CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking: 

• 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

• 

Do not 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

To reduce the risk of physical injury: 

•  Shut off inlet water supply and depressurize system as shown in manual prior to service.

To reduce the risk associated with a hazardous voltage:

•  If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a suffi cient ground connection across 

the water softener installation piping — refer installation to qualifi ed personnel.

• 

Do not

 use the system if the power cord is damaged — contact qualifi ed service personnel for repair.

To reduce the risk associated with back strain due to the heavy weight of the various system components:

•  Follow safe lifting procedures.

 CAUTION

To reduce the risk associated skin, eye, and respiratory tract irritation from gravel and fi lter media during installation:

•  Gravel and several types of fi lter media may be used in this product, depending upon the application.  During installation, dust may cause irritation to skin, eyes, and 

respiratory tract.

•  Utilize a NIOSH-approved dust fi lter mask, protective gloves, and appropriate eye protection when handling and pouring gravel and fi lter media.
•  To request an MSDS relating to this product, call 203-238-8965 or go to www.3M.com, select country, and use the search engine to search MSDS.  For emergen-

cies, call 800-364-3577 or 651-737-6501 (24 hours).

CAUTION

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow 

Use instructions before installation and use of this water treatment system.

•  Installation and use 

MUST

 comply with existing state or local plumbing codes.

• 

Protect from freezing

, relieve pressure and drain system when temperatures are expected to drop below 40°F (4°C).

• 

Do not

 install on hot water supply lines.  The maximum operating water temperature of this water softener is 110°F (43.3°C).

• 

Do not

 install if water pressure exceeds 125 psi.  If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumbing 

professional if you are uncertain how to check your water pressure.

• 

Do not

 install where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer arrester.  Contact a plumbing profes-

sional if you are uncertain how to check for this condition.

•  Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.
• 

Do not

 use a torch or other high temperature sources near system.

•  On plastic fi ttings, never use pipe sealant or pipe dope. 

Use PTFE thread tape only,

 pipe dope properties may deteriorate plastic.

•  Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if over tightening occurs.
• 

Do not

 install in direct sunlight or outdoors.

•  Install system in such a position as to prevent it from being struck by other items used in the area of installation.
•  Ensure all tubing and fi ttings are secure and free of leaks.
• 

SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER

 after water is shut off.

• 

Do not

 install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.

• 

Do not

 apply heat to any fi tting connected to bypass or control valve as damage may result to internal parts or connecting adapters.

•   Install on a fl at/level surface. It is also advisable to sweep the fl oor to eliminate objects that could pierce the brine tank.

To reduce the risk associated with property damage due to plugged water lines:

•  Pay particular attention to correct orientation of control valve. Water fl ow should match arrow on control valve. The Inlet and Outlet of other water treatment 

equipment products will vary depending on the control valve brand used.

IMPORTANT NOTES

• 

Failure to follow instructions will void warranty.

Содержание Aqua-Pure CS Series

Страница 1: ...DENTIAL WATER SOFTENERS MODELS CS1001 CSM1001 CS1501 CSM1501 CS2001 CSM2001 INSTR2201 0312 Installer please leave with homeowner Homeowner retain for future reference CLICK ANYWHERE on THIS PAGE to RE...

Страница 2: ...nd appropriate eye protection when handling and pouring gravel and filter media To request an MSDS relating to this product call 203 238 8965 or go to www 3M com select country and use the search engi...

Страница 3: ...care Damage can result if dropped or if the brine tank is set on sharp uneven projections on the floor When handling do not turn the water softener unit upside down or on its side to help prevent medi...

Страница 4: ...RTANT NOTE If sediment is present the installation of a sediment pre filter is recommended Even if sediment is not currently present or at a level high enough to be objectionable a pre filter can help...

Страница 5: ...age due to plugged water lines Pay particular attention to correct orientation of control valve Water flow should match arrow on control valve The Inlet and Outlet of other water treatment equipment p...

Страница 6: ...IN WASTE DRAIN WASTE DRAIN WASTE DRAIN WATER SOFTENER BACKWASH FILTER CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use instructions before installati...

Страница 7: ...pass or control valve as damage may result to internal parts or connecting adapters Make certain water flow enters through inlet and discharges through outlet Loosen set screw and pull out drain line...

Страница 8: ...position See How To Manually Regenerate Your Water Soft ener At Any Time and then unplug power cord to prevent the unit from advancing automatically Step 11 Partially open inlet valve in plumbing or...

Страница 9: ...id legs Then add initial salt fill to brine tank and one cup full of unscented laundry bleach to brine well Step 15 Put softener through complete regeneration to sanitize the system before use Refer t...

Страница 10: ...and locate box intersected by 4 in family and 20 gpg adjusted hardness The figure 3 in box indicates a REGENERATION frequency of THREE TIMES PER 12 DAYS if a 1 2 4 etc were in box frequencies of once...

Страница 11: ...2 2 2 2 2 2 2 2 1 1 1 1 1 2 1 2 2 2 2 3 3 3 3 3 3 4 3 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 6 6 6 4 1 1 2 2 2 3 2 3 4 4 4 6 6 6 6 6 6 12 5 1 1 2 2 3 3 3 4 4 6 6 6 6 12 12 12 12 12 6 1 2 2 3 3 4 3 6 6 6 6 12 1...

Страница 12: ...hree hours and stop in the position shown in the drawing SERVICE POSITION Even though it takes three hours for this center knob to complete one revolution the regeneration cycle of your unit might be...

Страница 13: ...OF BRINE AND RINSE TIME The group of holes between the last pin in the backwash section and the second group of pins determines the length of time that your unit will brine and rinse 2 min per hole T...

Страница 14: ...ns arrow denotes remaining gallons exclusive of fixed reserve HOW TO SET TIME OF DAY 1 Press and hold the red button in to disengage the drive gear 2 Turn the large gear until the actual time of day i...

Страница 15: ...ply the softener mineral bed will eventually become iron fouled resulting in reduced softening capacity and rust stained fix tures Mixing one to two ounces of Mineral Cleaner with every 80 lbs of salt...

Страница 16: ...day A Power outage occurred A Reset time clock 6 Water continuously flows to drain A Foreign material in control valve A Remove piston assembly and inspect bore remove foreign material and check contr...

Страница 17: ...aximum Setting 6 2 7 15 0 6 8 9 4 1 24 10 9 12 5 4 24 10 9 Softening Capacity grains 1 At Factory Salt Setting At Maximum Salt Setting 18 600 30 000 27 900 45 000 37 200 54 000 Flow Rate gpm lpm 2 Ser...

Страница 18: ...Media Tank w Base 6236001 0844 6236001 1044 6236001 1054 5 Distributor Tube Assembly 62362 32 62362 32 62362 36 6 Media H 050P 2 H 050P 3 H 050P 4 7 Brine Line Tubing 13000X 13000X 13000X 8 Brine Tank...

Страница 19: ...7 3 CEC 1000 SERIES SOFTENER CONTROL 12 DAY TIME CLOCK...

Страница 20: ...2 00 a m Init Incl Ref Items 39 53 K L 24 Hour Gear Assy Incl Ref Items 46 54 57 Skipper Wheel Assy Incl Ref Items 46 58 62 Drive Motor Assy Complete Incl Ref Items 63 65 67 N Drive Cam Assy Black ST...

Страница 21: ...CEC 1000 SERIES SOFTENER CONTROL METER INITIATED 7 4...

Страница 22: ...Incl Ref Items 66 68 Optional Cover Mounting Screw 1650 Brine Valve Assy w BLFC Screw Adapter Coupling Adapter Clip Coupling O ring 1 Adapter Yoke NPT 3 4 Adapter Yoke NPT Control Valve Body CEC1000...

Страница 23: ...RAM RE SET SWITCH WHITE BLUE RAPID RINSE BRINE TANK FILL BACKWASH PROGRAM SWITCH BRINE AND RINSE BROWN BLACK BLACK BLACK YELLOW BLACK B L A C K B L A C K SWITCH SERVICE CAM SERVICE CAM RAPID RINSE BRI...

Страница 24: ...e remedy and 3M Purification Inc s exclusive obligation Warranty Period One 1 year on the entire product unit Five 5 years on the media tank only does not include internal component parts Five 5 years...

Отзывы: