background image

4

CAUTION

CAUTION

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow

 Use Instructions before installation and use of this system.

• Installation and use 

MUST

 comply with all state and local plumbing codes.

• 

Protect from freezing

, remove 

fi

 lter cartridge when temperatures are expected to drop 

below 40° F (4.4° C).

• 

Do not

 install systems in areas where ambient temperatures may go above 110° F (43.3° C).

• 

Do not install on hot water supply lines.

 The maximum operating water temperature of 

this system is 100°F (37.8°C).

• 

Do not

 install if water pressure exceeds 120 psi (827 kPa). If your water pressure 

exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumbing 
professional if you are uncertain how to check your water pressure.

• 

Do not install

 where water hammer conditions may occur. If water hammer conditions 

exist you must install a water hammer arrester. Contact a plumbing professional if you are 
uncertain how to check for this condition.

• Where a back

fl

 ow prevention device is installed on a water system, a device for controlling 

pressure due to thermal expansion must be installed.

• 

Do not

 use a torch or other high temperature sources near system, cartridges, plastic 

fi

 ttings or plastic plumbing.

• On plastic 

fi

 ttings, never use pipe sealant or pipe dope. Use PTFE thread tape 

only

, pipe 

dope properties may deteriorate plastic.

• Take care when using pliers or pipe wrenches to tighten plastic 

fi

 ttings, as damage may 

occur if over tightening occurs.

• 

Do not install

 in direct sunlight or outdoors.

• 

Do not install

 near water pipes which will be in path of a drilling tool when selecting the 

position to mount the bracket.

• Mount system in such a position as to prevent it from being struck by other items used in 

the area of installation.

• Ensure that the location and fasteners will support the weight of the system when installed 

and full of water.

• Ensure all tubing and 

fi

 ttings are secure and free of leaks.

• 

Do not install

 unit if collet is missing. Contact 1-866-990-9785 if collets are missing from 

any 

fi

 ttings.

• SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is 

shut off.

• The disposable 

fi

 lter cartridge 

MUST

 be replaced every six (6) months, at the rated 

capacity or sooner if a noticeable reduction in 

fl

 ow rate occurs.

IMPORTANT NOTES

IMPORTANT NOTES

• Failure to follow instructions will void warranty.
• Allow a minimum of 2" (5 cm) clear space under 

fi

 lter to facilitate cartridge change.

• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.

Содержание Aqua-Pure AP Easy Series

Страница 1: ...Installation and Operating Instructions For AP Easy Series Drinking Water Systems Models CS S LC Complete Installer Please leave manual with homeowner...

Страница 2: ......

Страница 3: ...he system installation piping refer installation to qualified personnel To reduce the risk associated with choking Do not allow children under 3 years of age to have access to small parts during the i...

Страница 4: ...temperature sources near system cartridges plastic fittings or plastic plumbing On plastic fittings never use pipe sealant or pipe dope Use PTFE thread tape only pipe dope properties may deteriorate p...

Страница 5: ...er If a faucet hole needs to be drilled for faucet Center punch File or grinding wheel 9 16 Drill bit suitable for countertop materials or cast iron stainless steel sink 1 2 4 6 5 3 1 2 4 3 5 6 GETTIN...

Страница 6: ...be from the faucet stem Locate the 1 4 Feedwater Adapter that came with your Drinking Water System Insert the black gasket into the threaded adapter and tighten onto the Faucet Cold Water Stem under t...

Страница 7: ...ing and faucet stem down through faucet mount ing hole 3 From underneath sink assemble the black spacer star washer and hex nut as shown onto the threaded brass stem and tighten by hand 4 With a padde...

Страница 8: ...ridge with existing filter head and insert new filter cartridge into head Turn cartridge to the right clockwise until cartridge stops 4 Open the inlet shut off valve and flush new cartridge for four 4...

Страница 9: ...ificado para hacer la instalaci n Para reducir el riesgo asociado a la asfixia No permita que los ni os menores a 3 a os tengan acceso a piezas peque as durante la instalaci n de este producto Para re...

Страница 10: ...a la dilataci n t rmica No use soplete ni otra fuente de alta temperatura cerca del sistema de filtros cartuchos o acoples y tuber as de pl stico En los acoples pl sticos nunca utilice sellador o peg...

Страница 11: ...ornillador con cabeza Phillips Cuchillo o cortador de tuber a Si se necesita perforar un agujero para el grifo Punz n Lima o rueda amoladora Broca de 9 16 pulgadas para uso con el material de la mesad...

Страница 12: ...el tubo de suministro del agua fr o del v stago del grifo Ubique el adaptador de entrada del agua de 1 4 de pulgada que vino con su sistema de agua potable Inserte la junta negra en el adaptador con...

Страница 13: ...tuber a azul y el v stago del grifo a trav s del agujero de montaje del grifo 3 Desde abajo del fregadero arme el espaciador negro arandela estrella y tuerca hexagonal como se indica sobre el v stago...

Страница 14: ...ue el borde exterior del revestimiento de decoraci n Corte la base de metal del fregadero 1 Agarre el cartucho y g relo hacia la izquierda contrario a las agujas del reloj hasta que el cartucho se det...

Страница 15: ...el accesorio a presi n Aseg rese de que el corte de la tuber a sea recto Caso contrario vuelva a cortarlo Si hay una fuga de agua verifique que la junta t rica est debidamente colocada en su ranura N...

Страница 16: ......

Страница 17: ...erie de filtre un technicien qualifi doit faire l installation Mesures pour r duire les risques associ s l touffement Interdire l acc s aux petites pi ces aux enfants de moins de 3 ans pendant l insta...

Страница 18: ...jamais utiliser de produit d tanch it ou d enduit d enrobage pour tuyau sur les adaptateurs en plastique Utiliser uniquement un ruban de polyt trafluoro thyl ne PTFE pour filet pour viter la d t riora...

Страница 19: ...tuyau S il est n cessaire de percer un trou pour installer le robinet Pointeau Lime ou meule M che de 14 29 mm 9 16 po convenant au mat riau du rev tement de comptoir ou l vier de fonte d acier inoxyd...

Страница 20: ...adaptateur d alimentation 1 4 po fourni avec le syst me d eau potable Ins rer le joint d tanch it noir dans l adaptateur filet et visser dans la branche du robin d eau froide sous l vier en s assurant...

Страница 21: ...faire ensuite passer le tuyau bleu et la tige du robinet dans l orifice d installation de l vier 3 Sous l vier assembler la pi ce d espacement noire la rondelle ven tail et l crou hexagonal tel qu ill...

Страница 22: ...ne touche pas l autre bordure du rev tement d coratif Percer travers la base de m tal de l vier 1 Saisir la cartouche et tourner vers la gauche dans le sens inverse des aiguilles d une montre jusqu ce...

Страница 23: ...e raccordement poussoir S assurer que le tuyau est coup bien droit Sinon tailler de nouveau En cas de fuite v rifier que le joint torique est bien appuy dans sa rainure L eau ne s coule pas du robinet...

Страница 24: ...ARISING OUT OF A COURSE OF DEALING CUSTOMER OR USAGE OF TRADE If the Product fails to satisfy this Limited Warranty during the warranty period 3M will replace the Product or refund your Product purch...

Отзывы: