background image

5

Table of Contents

WARNING

!

This respirator helps protect against certain particles. 

Misuse may result in sickness or death.

 For correct use, consult 

supervisor and these User Instructions, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 

1-800-267-4414. In Mexico, call 01-800-712-0646.

1)

IMPORTANT

....................................................................................................................................................................................................5

2)

Use For

..............................................................................................................................................................................................................5

3)

Do Not Use For

...............................................................................................................................................................................................5

4)

Biological Particles

........................................................................................................................................................................................5

5)

Use Instructions

..............................................................................................................................................................................................5

6)

Use Limitations

...............................................................................................................................................................................................6

7)

Storage Conditions and Shelf Life

............................................................................................................................................................6

8)

Time Use Limitation

......................................................................................................................................................................................7

9)

Fitting Instructions

.........................................................................................................................................................................................7

10)

Removal Instructions

....................................................................................................................................................................................7

11)

NIOSH Approved: N95

................................................................................................................................................................................7

12)

Contact

............................................................................................................................................................................................................8

IMPORTANT

Before use, wearer must read and understand these 

User Instructions

. Keep these instructions for reference.

Use For

Particles such as those from grinding, sanding, sweeping, sawing, bagging, or processing minerals, coal, iron ore, flour, metal, 

wood, pollen, and certain other substances. Liquid or non-oil based particles from sprays that do not also emit oil aerosols or 

vapors. Follow all applicable local regulations. In the U.S., for additional information on 3M use recommendations for this class 

of respirator please consult the 3M Respirator Selection Guide found on the PSD web site at www.3M.com/respiratorselector 

or call 1-800-243-4630 in U.S.A. In Canada, call 1-800 267-4414.

Do Not Use For

Do not use for gases and vapors, oil aerosols, or sandblasting, unless nozzle and blast are physically separated from the 

operator in an exhaust-ventilated enclosure; particulate concentrations that exceed either 10 times the occupational exposure 

limit or applicable government regulations, whichever is lower. This respirator does not supply oxygen. In the U.S., do not use 

when OSHA substance specific standards, such as those for asbestos, arsenic, cadmium, lead in the construction industry, or 

4,4’-methylene dianiline (MDA), specify other types of respiratory protection.

Biological Particles

This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, 

Bacillus anthracis

Mycobacterium tuberculosis

, etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other 

government agencies have not established safe exposure limits for these contaminants.

Use Instructions

1)

Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during

all times of exposure can reduce respirator effectiveness and 

may result in sickness or death.

2)

Before occupational use of this respirator, in the U.S. a written respiratory protection program must be implemented

meeting all the requirements of OSHA 29 CFR 1910.134 such as training, fit testing, medical evaluation, and applicable

Occupational/Workplace Use: 3M™ 9205+ and 9210+ N95 User Instructions

Содержание 9205 Plus

Страница 1: ...spirator Table of Contents 1 General Use 3M 9205 and 9210 N95 User Instructions 2 2 Occupational Workplace Use 3M 9205 and 9210 N95 User Instructions 5 Check out 3m com myN95 for more information about 3M N95 Respirators User Instructions ...

Страница 2: ...e pre existing lung disease such as asthma or emphysema underlying heart disease such as heart failure or other health conditions that may cause difficulty breathing through some respirators then you should consult your healthcare provider before use Standards regulating respirator training and use for the general public have not been established For your respirator to help reduce the number of pa...

Страница 3: ... to breathe through You should never wash disinfect put in an oven or other home appliance or share your respirator with others 8 Storage Until they are needed for use N95s should be stored indoors in their original packaging when possible and in a space where they can t become crushed or distorted Store at temperatures between 4 F and 86 F and 80 relatively humidity If a respirator will be stored...

Страница 4: ...rough the respirator filter For non valved respirators Place one or both hands completely over the middle panel Inhale and exhale sharply If air leaks around your nose readjust the nosepiece If air leaks between the face and faceseal of the respirator reposition it by adjusting the panels and straps If you cannot achieve a proper seal do not enter the contaminated area See your supervisor For valv...

Страница 5: ...e For Do not use for gases and vapors oil aerosols or sandblasting unless nozzle and blast are physically separated from the operator in an exhaust ventilated enclosure particulate concentrations that exceed either 10 times the occupational exposure limit or applicable government regulations whichever is lower This respirator does not supply oxygen In the U S do not use when OSHA substance specifi...

Страница 6: ...e government regulations whichever is lower 3 Do not alter wash abuse or misuse this respirator 4 Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator 5 Respirators can help protect your lungs against certain airborne contaminants however they will not prevent entry through other routes such as the skin ...

Страница 7: ...ur fingertips from both hands at the top of the metal nosepiece Using two hands mold the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece NOTE Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance Use two hands 5 Perform a User Seal Check prior to each wearing To check the respir...

Страница 8: ... 243 4630 For other 3M products 1 800 3M HELPS or 1 651 737 6501 3M PERSONAL SAFETY DIVISION 3M CENTER BUILDING 0235 02 W 70 ST PAUL MN 55144 1000 3M is a trademark of 3M Company used under license in Canada 3M PSD products for occupational use only Occupational Workplace Use 3M 9205 and 9210 N95 User Instructions ...

Отзывы: