background image

3M

 Personal Safety Division  |  3M

 Particulate Respirators 8825+ and 8835+ 

Version: 1
This version is the sole document applicable to the product(s) since its date of publication

Warnings and Use Limitations

 

Ŕ

 Always be sure that the complete product is:

 

Suitable for the application;

 

Fitted correctly;

 

Worn during all periods of exposure;

 

Replaced when necessary. 

 

Ŕ

Proper selection, training, use and appropriate 

maintenance are essential in order for the product to help 

protect the wearer from certain airborne contaminants. 

Failure to follow all instructions on the use of these 

respiratory protection products and/or failure to properly 

wear the complete product during all periods of exposure 

may adversely affect the wearer’s health, lead to severe or 

life threatening illness or permanent disability. 

 

Ŕ

For suitability and proper use follow local regulations, 

refer to all information supplied or contact a safety 

professional/3M representative.

 

Ŕ

Before use, the wearer must be trained in use of the 

complete product in accordance with applicable Health and 

Safety standards/guidance.

 

Ŕ

These products do not contain components made from 

natural rubber latex.

 

Ŕ

These products do not protect against gases/vapours.

 

Ŕ

Do not use in atmospheres containing less than 19.5% 

oxygen. (3M definition. Individual countries may apply their 

own limits on oxygen deficiency. Seek advice if in doubt). 

 

Ŕ

Do not use for respiratory protection against atmospheric 

contaminants/concentrations which are unknown or 

immediately dangerous to life and health (IDLH).

 

Ŕ

Do not use with beards or other facial hair that may 

inhibit contact between the face and the product thus 

preventing a good seal.

 

Ŕ

Leave the contaminated area immediately if:

 

Breathing becomes difficult.

 

Dizziness or other distress occurs.

 

Ŕ

 For single shift use or reusable devices: Discard and replace 

the respirator if it becomes damaged, breathing resistance 

becomes excessive or at the end of the shift*.

*The respirators are re-usable and can be cleaned and used 

for more than one shift.

 

Ŕ

Never alter, modify or repair this device.

 

Ŕ

Before initial use, always check that the product is within 

the stated shelf life (use by date).

Fitting Instructions

See Figure 1.

Before fitting device, ensure hands are clean.

All respirator components should be inspected for damage 

prior to each use.

1.  Thread top elastic strap through top buckles. Repeat for 

bottom strap and buckles.

2.  Hold respirator under chin, with nosepiece up.

3.  Locate the upper strap across the crown of the head and 

the lower strap below the ears. Straps must not be twisted.

4. 

4A.  Adjust tension: Increase - pull evenly on both ends of the 

top/bottom straps. 

4B.  Adjust tension: Decrease - without removing respirator, 

push out on the back of the buckles.

5. 

5A. Ensure face seal is properly formed around the nose. 

5B.  The face seal must not be folded in.

6.  The seal of the respirator on the face should be fit-

checked before entering the workplace. 

Fit Check 

1.  Cover the front of the respirator with both hands being 

careful not to disturb the fit of the respirator.

2.  VALVED respirator - INHALE sharply. 

3.  If the air leaks around the nosepiece, re-adjust the 

respirator and face seal upon the face to eliminate leakage. 

Repeat the fit check.

4.  If air leaks at the respirator edges, adjust the tension of the 

straps to eliminate the leakage. Repeat the above fit check.

If you CANNOT achieve a proper fit DO NOT enter the 

hazardous area. 

See your supervisor.

Users should be fit tested in accordance with national 

requirements. For information regarding fit testing 

procedures, please contact 3M.

1

2

3

4A

4B

5A

5B

6

Figure 1

Содержание 8825+

Страница 1: ...e when the wearer is exposed to hazards Standards Products are classified by filtering efficiency and maximum total inward leakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in this standard include filter penetration extended exposure loading test flammability breathing resistance and total inward leakage Reusable products are also subjected to clea...

Страница 2: ...ator 3 0 mbar valved respirator Flammability Tested respirators are mounted on a metallic head which rotates with a linear speed of 60mm s The respirators are passed within 20mm of the tip of an 800o C 50o C propane burner flame The respirator shall not burn or continue to burn within 5 seconds of removal from the flame Components and materials The following materials are used in the production of...

Страница 3: ...ted area immediately if Breathing becomes difficult Dizziness or other distress occurs Ŕ Ŕ For single shift use or reusable devices Discard and replace the respirator if it becomes damaged breathing resistance becomes excessive or at the end of the shift The respirators are re usable and can be cleaned and used for more than one shift Ŕ Ŕ Never alter modify or repair this device Ŕ Ŕ Before initial...

Страница 4: ... assumes that the user has previous experience of this type of product and that it will be used by a competent professional Before any use of this product it is recommended to complete some trials to validate the performance of the product within its expected application All information and specification details contained within this document are inherent to this specific 3M product and would not ...

Отзывы: