background image

3M

 Personal Safety Division  |  3M

 Particulate Respirators 8825+ and 8835+ 

Version: 1
This version is the sole document applicable to the product(s) since its date of publication

Breathing resistance

The breathing resistance of the respirator is tested during 

inhalation (continuous flow) and exhalation (cyclical flow). The 

breathing resistance of the respirators shall not exceed the 

following limits:

EN 149:2001+A1:2009 

Classification

Maximum Breathing Resistance

Inhalation at 

30l/min

Inhalation at 

95l/min

Exhalation at 

160l/min

FFP2

0.7 mbar

2.4 mbar

3.0 mbar

FFP3

1.0 mbar

3.0 mbar

3.0 mbar

Clogging

For single shift use respirators (NR), the clogging test is 

optional. For re-usable respirators (R) this test is mandatory. 

The respirators are loaded with very high amount of Dolomite 

dust which will tend to clog the filter. After loading with the 

required amount of dust, the breathing resistance of the 

respirators shall not exceed the following limits:

EN 149:2001+A1:2009 

Classification

Maximum Breathing Resistance

Inhalation at 95l/min

Exhalation at 160l/min 

(continuous flow)

FFP2

5.0 mbar (valved 

respirator) 

4.0 mbar (unvalved 

respirator)

3.0 mbar (valved 

respirator)

FFP3

7.0 mbar (valved 

respirator) 

5.0 mbar (unvalved 

respirator)

3.0 mbar (valved 

respirator)

Flammability

Tested respirators are mounted on a metallic head which 

rotates with a linear speed of 60mm/s. The respirators are 

passed within 20mm of the tip of an 800

o

C (±50

o

C) propane 

burner flame. The respirator shall not burn or continue to burn 

within 5 seconds of removal from the flame.

Components and materials

The following materials are used in the production of the 

3M

 Particulate Respirators 8825+ and 8835+:

Component

Material

Straps (blue for FFP2 and red 

for FFP3)

Cotton / Polyisoprene / 

Polypropylene

Tension adjustable buckles

Polypropylene

Filter / Inner Shell

Polypropylene / Polyester

Cool Flow

 Valve

Polypropylene / Polyisoprene

Face seal (can be 

hygienically cleaned)

Thermoplastic elastomer (TPE)

These products do not contain components made from 

natural rubber latex, PVC and metals.

Product

Typical weight

3M

 Particulate 

Respirator 8825+

35g

3M

 Particulate 

Respirator 8835+

40g

Storage and Transportation

3M

 Particulate Respirators 8825+ and 8835+ have a shelf 

life of 5 years from date of manufacture. End of shelf life 

is marked on the product packaging and upon the product 

headband. Before initial use, always check that the product 

is within the stated shelf life (use by date). Product should 

be stored in clean, dry conditions within the temperature 

range: – 20°C to + 25°C with a maximum relative humidity of 

<80%. When storing or transporting this product use original 

packaging provided. 

Содержание 8825+

Страница 1: ...e when the wearer is exposed to hazards Standards Products are classified by filtering efficiency and maximum total inward leakage performance FFP1 FFP2 and FFP3 also by usability and clogging resistance Performance tests in this standard include filter penetration extended exposure loading test flammability breathing resistance and total inward leakage Reusable products are also subjected to clea...

Страница 2: ...ator 3 0 mbar valved respirator Flammability Tested respirators are mounted on a metallic head which rotates with a linear speed of 60mm s The respirators are passed within 20mm of the tip of an 800o C 50o C propane burner flame The respirator shall not burn or continue to burn within 5 seconds of removal from the flame Components and materials The following materials are used in the production of...

Страница 3: ...ted area immediately if Breathing becomes difficult Dizziness or other distress occurs Ŕ Ŕ For single shift use or reusable devices Discard and replace the respirator if it becomes damaged breathing resistance becomes excessive or at the end of the shift The respirators are re usable and can be cleaned and used for more than one shift Ŕ Ŕ Never alter modify or repair this device Ŕ Ŕ Before initial...

Страница 4: ... assumes that the user has previous experience of this type of product and that it will be used by a competent professional Before any use of this product it is recommended to complete some trials to validate the performance of the product within its expected application All information and specification details contained within this document are inherent to this specific 3M product and would not ...