background image

 

4

substance specific standards.  In Canada, CSA standard Z94.4 requirements must be met and/or 
requirements of the applicable jurisdiction, as appropriate. ** 

 

 

 

3.  The particles which can be dangerous to your health include those so small that you cannot see them. 

4.

 

Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress 
occurs. 

5.

 

Store the respirator away from contaminated areas when not in use. 

6.

 

Inspect respirator before each use to ensure that it is in good operating condition. Examine all the 
respirator parts for signs of damage including the two headbands, attachment points and noseclip. The 
respirator should be disposed of immediately upon observation of damaged or missing parts.  Filtering 
facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other 
than the punctures around staples and no damage has occurred.  Enlarged holes resulting from ripped or 
torn filter material around staple punctures are considered damage.  Immediately replace respirator if 
damaged.  Staple perforations do not affect NIOSH approval. 

 

7.

 

Dispose of used product in accordance with applicable regulations. 

 

 

Use Limitations 

1.  This respirator does not supply oxygen.  Do not use in atmospheres containing less than 19.5% oxygen. 

2.  Do not use when concentrations of contaminants are immediately dangerous to life and health, are 

unknown or when concentrations

 

exceed 10 times the permissible exposure limit (PEL) or according to 

specific OSHA standards or applicable government regulations, whichever is lower. * 

 

 

 

 

 

 

3.

 

Do not alter, wash, abuse or misuse this respirator. 

4.

 

Do not use with beards or other facial hair or other conditions that prevent a good seal between the face 
and the sealing surface of the respirator. 

5.

 

Respirators can help protect your lungs against certain airborne contaminants, however, they will not 
prevent entry through other routes such as the skin, which would require additional personal protective 
equipment (PPE). 

6.

 

This respirator is designed for occupational/professional use by adults who are properly trained in it’s use 
and limitations. Respirators are not designed to be used by children. 

7.

 

Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a 
physician and complete a medical evaluation prior to use. 

8.

 

When stored in accordance with temperature and humidity conditions specified below, the product may 
be used until the “use by” date specified on the packaging. 

 

** For Use in China: For the selection, use and maintenance of respirator, please refer to China 
national standard GB/T 18664. 

* For Use in China: Do not use for oil based particles. Do not use for particles in concentrations that 
exceed the maximum allowable concentration required by the applicable regulation and standard. The 
maximum allowable concentration is obtained by multiplying the Assigned Protection Factor (APF) 
provided by GB/T 18664 “Selection, Use and Maintenance of Respiratory Protective Equipment” and 
the permissible Occupational Exposure Limit (OEL) of the contaminant. 

Содержание 8511CN

Страница 1: ...1 98 0060 0187 3 2 8511CN Respirator P95 User Instructions Insert Activity Summary Initials Date Comments LA 8 2011 Initial submission EJ 3 2020 Update GB2626 to 2019 Add clarification re sandblasting ...

Страница 2: ...eference 98 0060 0187 3 2 This respirator has dual approval as a United States US National Institute for Occupational Safety and Health NIOSH N95 particulate respirator and as a China GB2626 2019 KN95 particulate respirator Specific information is provided where applicable GB2626 2019 KN95 ...

Страница 3: ...ction industry or 4 4 methylene dianiline MDA specify other types of respiratory protection This respirator does not supply oxygen Biological Particles This respirator can help reduce inhalation exposures to certain airborne biological particles e g mold Bacillus anthracis Mycobacterium tuberculosis etc but cannot eliminate the risk of contracting infection illness or disease OSHA and other govern...

Страница 4: ...10 times the permissible exposure limit PEL or according to specific OSHA standards or applicable government regulations whichever is lower 3 Do not alter wash abuse or misuse this respirator 4 Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator 5 Respirators can help protect your lungs against certain ...

Страница 5: ...conduct a user seal check before use as specified in User Instructions If you cannot achieve a proper seal do not enter the contaminated area See your supervisor Time Use Limitation If respirator becomes damaged soiled or breathing becomes difficult leave the contaminated area immediately and replace the respirator Fitting Instructions Must be followed each time respirator is worn 4o F 20o C 86o F...

Страница 6: ...inward while moving your fingertips down both sides of the nosepiece Fig 3 Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance Use two hands 4 Perform a User Seal Check prior to each wearing To check the respirator to face seal place both hands completely over the respirator and inhale sharply Fig 4 Be careful not to disturb the position of th...

Страница 7: ... and cup respirator in hand to maintain position on face Pull bottom strap over head Still holding respirator in position pull top strap over head and remove respirator This respirator contains no components made from natural rubber latex ...

Страница 8: ...do not contain oil FOR MORE INFORMATION In China contact Website www 3M com cn PPE Tel 86 21 22105335 3M 2020 All rights reserved 3M is a trademark of 3M Company For Use in China GB2626 2019 approved KN95 At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil ...

Страница 9: ...9 3M China Co Ltd 222 TianLin Road Shanghai China 200233 Tel 021 2210 5335 Fax 021 2210 5035 3M PSD products are for occupational use only ...

Отзывы: