2.

Adjust head cradle size to fit comfortably on head.

3.

While holding head harness strap ends with one hand, slide
the facepiece up onto your face as shown below.

Both Types of Suspension

4.

Take the bottom straps in both hands, place them at the back
of the neck and hook them together.

5.

Tighten the top straps first by pulling on ends to achieve a
comfortable and secure fit as shown.

6.

Tighten bottom straps using the rear adjustments (strap
tension may be decreased by pushing out on back side
of buckles).

7.

Perform a positive and/or negative pressure face fit check.

Face Fitting

The negative pressure fit check is recommended when using the 6035,
6038 and 2000 Series filters; the positive pressure fit check is
recommended when using other filters.

Positive Pressure Facefit Check

Place the palm of the hand over the exhalation valve cover and exhale
gently.

If the facepiece bulges slightly and no air leaks between the face and
the facepiece are detected, a proper fit has been achieved.

If air leakage is detected, reposition the respirator on the face and/or
readjust the elastic strap to eliminate the leakage.

Repeat the above facefit check.

Negative Pressure Facefit Check

For the 2000 Series filters, press your thumbs into the central
indentation of the filters, inhale gently and hold your breath for five or
ten seconds.

For the 6035 and 6038 filters, pinch the filter between thumb and
fingers to seal the filter cover to the body of the filter, inhale gently and
hold your breath for five or ten seconds.

If the facepiece collapses slightly a proper fit has been achieved.

If air leakage is detected, reposition the respirator on the face and/or
readjust the elastic strap to eliminate the leakage.

Repeat the above facefit check.

Fit Testing

The 3M 7500 Half Mask is a tight fitting facepiece and therefore
requires a fit test per wearer before use as per the COSHH regulations
2002.

For qualitative fit testing - 3M FT10 or FT30 fit test kits are available.
For quantitative fit testing - the 3M 601 adaptor is available.

Содержание 7501

Страница 1: ...nks and Dyes Aluminium Welding Agriculture Pharmaceutical FILTER 6051 A1 6055 A2 EN14387 2004 6054 K1 EN141 2000 6057 ABE1 EN141 2000 6059 ABEK1 EN141 2000 6075 A1 formaldehyde EN141 2000 6096 HgP3 EN141 2000 HAZARD Organic Vapours Ammonia Organic Vapours Inorganic and Acid Gases Organic Vapours Inorganic Gases Acid gases and Ammonia Organic Vapours and Formaldehyde Mercury and particulates INDUST...

Страница 2: ...EL or 1000ppm 5000ppm for 6055 whichever value is lower APF 10 Gas vapour filters should not be used to protect the wearer against a gas or vapour that has poor warning properties The 7500 Series facepieces when used with the 5911 filter may be used in concentrations of solid and aqueous aerosols up to 4 times WEL APF 4 The 7500 Series facepieces when used with the 5925 2125 or 2128 filters may be...

Страница 3: ...between the face and the facepiece are detected a proper fit has been achieved If air leakage is detected reposition the respirator on the face and or readjust the elastic strap to eliminate the leakage Repeat the above facefit check Negative Pressure Facefit Check For the 2000 Series filters press your thumbs into the central indentation of the filters inhale gently and hold your breath for five ...

Страница 4: ...ress occurs iv You taste or smell the contaminant or an irritation occurs 8 Store this device in a sealed container away from contaminated areas when not in use 9 Use strictly in accordance with facepiece and filter user instruction leaflet 3M definition minimum 19 5 by volume oxygen Respiratory protection is only effective if it is correctly selected fitted and worn throughout the time when the w...

Отзывы: