78-0013-6389-0-A 5
4.0 Terminal Grounding
4.1 Fasten a #6 AWG wire to the ground bar, which is located on the front of the unit. Connect the other end of the
ground wire to local ground per company standards.
Note: Failure to properly bond and ground the terminal per N.E.C. or local equivalent codes may render
protection arrestors useless.
5.0 Splicing
5.1 Splice the feeder cable group(s) to the appropriate 3M
™
Terminal Block Tail(s) per your company’s practice.
5.2 Bundle completed 3M
™
Splice Module(s) and secure them with 3M
™
Cable Ties within the splice chamber.
5.3 Close the splice chamber cover and secure the lock plate bolt.
6.0 Terminating Premise Wire–3M
™
Quick Connect System (QCS) 2811 Block
6.1 Open the feeder pair jumper cap by pushing up on
the latch and rotating up. Insert wire ends A (tip)
left and B (ring) right into wire openings in the cap,
making sure they are inserted all the way to the back
of the cap.
6.2 While holding the wires in place, close the cap and
press to snap the latch firmly into place.
6.3 Route the wires through wire loops on the block ends
and through vertical and horizontal wireways.
6.4 Terminate additional wires by repeating the above
procedure.
6.5 To remove the wires, open the cap and pull the wires
straight out from block.
6.6 Route the wire below the connected cap.