2
1.02 Terminal Wiring Schematics:
Protector
Module
From C.O.
Modular
Hardwire
Block
4488 Wiring Schematic
Protector
Module
From C.O.
Self Strip
Block
4588 Wiring Schematic
883706
1.03 Terminal Dimensions Table
Depth With
Opt. Cover
5"
(127 mm)
5"
(127 mm)
5"
(127 mm)
Depth
4"
(102 mm)
4"
(102 mm)
4"
(102 mm)
Width
12 1/2"
(318 mm)
12 1/2"
(318 mm)
12 1/2"
(318 mm)
Height
8"
(203 mm)
12"
(305 mm)
22"
(559 mm)
Model
4488-25
4588-25
4488-50
4588-50
4488-100
4588-100
4.0 Tool Requirements
The following tools are required to install the 3M
brand PETs:
Typical Entrance Cable
- Standard Hand Tools
- MS
2
Modular Splicing Rig
- MS
2
4044 Splice Head Frame Adapter
- "B" versions require 710 Connector Splicing Rig
Preconnectorized Entrance Cable or 4187
Extension Stubs
- Standard Hand Tools
- MS
2
Modular Spliing Rig or
- 4255 Hand Tool
6.0 Terminal Grounding
Fasten a #6 AWG wire to the ground bar which is
located on the front of the unit. Connect other end
of ground wire to local ground per company
standards.
Note:
Failure to properly bond and ground the
terminal per N.E.C. or local equivalent codes
may render protection arrestors useless.
3.0 Protector Specifications
To maintain UL Listing, only five pin protectors
that are UL Recognized or Listed can be used.
2.0 Accessories
2.01 Protective Covers - These hinged cover kits
provide mechanical protection of the protector
receptacle field, modular hardwire and Self Strip
blocks. A hasp is included if a padlock is
employed for added security. Models available
are: 4372-25; 4372-50; 4372-100; 4373-25;
4373-50; 4373-100.
2.02 4187 Extension Stubs - The extension stub is
a 25' (7.6 m) 26 AWG Alvyn cable,
preconnectorized on one end with a modular
connector base. The stub can be crimped to the
preconnectorized short stub to provide an
extension to the entrance cable. They are
available in 25, 50 and 100-pair sizes.
2.03 4327 SS Pair Probe - The 4327 SS Pair Probe
provides electrical access to a pair of 4320 Self
Strip contacts.
2.04 4347 Pair Test Clip - The 4347 Pair Test Clip
allows for test connections to be made to both Tip
and Ring binding post screw washers
simultaneously on all types of 3M brand Modular
Hardwire Blocks.
5.0 Terminal Locations
5.01 Locate terminal according to standard operating
procedures. Consider the following points as
much as possible:
a. Locate terminal inside building as close as
possible to cable entrance.
b. Locate terminal on a firm mounting surface
where it will be accessible to the technicians at
all times; where it can be reached without a
ladder; and where it will not project in a
hazardous manner.
CAUTION: Avoid locations near flammable
materials, ignitable gases, dust,
moisture, temperature extremes,
moving machinery, electric light and
power circuits, and electrical equipment.
c. Observe caution when exposing terminal to
chemicals in liquid or vapor form as they may
damage the plastic components.
5.02 Open the splicing chamber by removing the two screws
on the right-hand side of chamber door. Reinsert
screws in tapped holes to avoid losing screws.
5.03 Pull the preterminated short stub, insulated ground
wire, and accessories out of the splicing chamber.
5.04 Tape the mounting template to the designated
position and mark screw locations (3). Remove
mounting template.
5.05 Mount the terminal in designated position with the
three mounting screws provided.
5.06 Remove jumper wire retaining rings from poly bag
and install in face plate.
DOCUMENT
OBSOLETE