Use Limitation

This respirator does not supply oxygen. Do not use in 
atmospheres containing less than 19.5%* oxygen.

1.  Do not use for respiratory protection against atmospheric 

contaminants that have poor warning properties or are 
unknown or immediately dangerous to life and health (IDLH) 
or against contaminants which generate high heats of reaction 
with chemical filters.

2.  Do not misuse, alter, modify or repair this product.
3.  Do not use with beards or other facial hair that prevent direct 

contact between face and edge of the respirator.

4.  Do not use with unknown concentrations of contaminants.
5.  Do not use for escape purposes.
6.  Leave the work area immediately and check the integrity of 

the respirator and replace face mask if:
-  Damage has occurred or is apparent.
-  Breathing becomes difficult or increased breathing 

resistance occurs.

-  Dizziness or other distress occurs.
-  You taste or smell the contaminant or an irritation occurs.

7.  Store this device in a sealed container away from 

contaminated areas when not in use.

8.  Use strictly in accordance with respirator and filter user 

instruction leaflet.

9.  In case of intended use in explosive atmospheres, contact 3M 

technical service.

* 3M definition minimum 19.5% by volume oxygen

Fitting Instructions

Before assigning any respirator to be worn in a contaminated 
area, we recommend that a qualitative or quantitative fit check be 
performed before entering the workplace.

Fitting instructions must be followed each time the respirator is 
worn.

1.  Assemble/adjust head cradle by feeding the perforated strip 

through the buckle and pressing down on the stud at the 
required length. Repeat for second strip.

2.  Place the respirator over the face, fitting it comfortably on 

bridge of the nose, then pull the head harness over the crown 
of the head.

3.  If necessary remove the respirator and readjust the head 

cradle to a comfortable fit and repeat step 2.

4.  Take a bottom strap in each hand, place them at the back of 

the neck and hook the straps together

5.  Tighten the top head harness first by pulling on the ends to 

achieve a comfortable and secure fit. Tighten bottom straps in 
a similar manner. Strap tension may be decreased by pushing 
out on back side of buckles.

6.  (Where applicable) After tightening the head harness (see 5), 

slide the 4 plastic

Содержание 4000 Series

Страница 1: ...cord keeping Easy and secure fitting of neck strap and adjustment of head cradle Optional overspray guard prolongs the life of the particulate filter when paint spraying Maximum product weight of 320 grams Applications The 3M 4000 Series Reusable Half Face Masks come in a variety of different product options 3M 4251 FFA1P2 R D provides protection against organic vapours good warning properties and...

Страница 2: ...ation under Article 10 EC Type Examination has been issued for these products by INSPEC International Limited 56 Leslie Hough Way Salford Greater Manchester M6 6AJ UK Notified Body number 0194 Certification under Article 11 EC quality control has been issued by BSI Product Services Notified Body number 0086 Cleaning and Storage If the respirator is to be used for more than one shift it should be c...

Страница 3: ...cordance with respirator and filter user instruction leaflet 9 In case of intended use in explosive atmospheres contact 3M technical service 3M definition minimum 19 5 by volume oxygen Fitting Instructions Before assigning any respirator to be worn in a contaminated area we recommend that a qualitative or quantitative fit check be performed before entering the workplace Fitting instructions must b...

Страница 4: ...ou cannot achieve a proper fit do not enter the contaminated area See your supervisor Important Notice 3M does not accept liability of any kind be it direct or consequential including but not limited to loss of profits business and or goodwill arising from reliance upon any information herein provided by 3M The user is responsible for determining the suitability of the products for their intended ...

Отзывы: