background image

Filter Table

Filter

Hazard

Industry

4251

(FFA1P2 R D)

4255

(FFA2P3 R D)

Organic Vapours

and Particulates

•  Anywhere conventional paints are used.  

(non-Isocyanates, subject to usage 

conditions)

•  Vehicle manufacture

•  Plant equipment manufacture

•  Shoe treatment and tanneries

•  Domestic appliance manufacture

•  Aircraft manufacture and refurbishment

•  Boat building

•  Machinery manufacture

•  Chemical manufacture and handling

•  Ink and dye manufacture and usage

•  Adhesive manufacture and laboratories

•  Paint and varnish manufacture

•  Manufacture and use of resins

4277

(FFABE1P3 R D)

Organic Vapours, 

Inorganic Gases, 

Acid Gases and 

Particulates

As 4251 but also:

•  Electrolytic processes

•  Acid cleaning

•  Metal pickling

•  Metal etching

4279

(FFABEK1P3 R D)

Organic Vapours, 

Inorganic and 

Acid Gases, plus 

Ammonia and 

Particulates

As 4277 but also:

•  Manufacture and maintenance of 

refrigeration equipment

•  Agrochemicals

Standards and Approval

The 3M™ 4000 Series Respirators meet the performance 
requirements of the European Standard EN 405:2001+A1:2009 
for valved filtering half-mask respirators for gases, vapours and 
particulate combinations.

The 3M™ 4000 Series Respirators have met the requirements 
of the European Community Directive 89/686/ EEC (Personal 
Protective Equipment Directive) and are thus CE marked. 
Certification under Article 10, EC Type- Examination, has been 
issued for these products by INSPEC International Limited, 56 
Leslie Hough Way, Salford, Greater Manchester M6 6AJ, UK 
(Notified Body number 0194). Certification under Article 11, EC 
quality control, has been issued by BSI Product Services (Notified 
Body number 0086).

Cleaning and Storage

If the respirator is to be used for more than one shift it should 
be cleaned at the end of each shift and stored between shifts 
in the original packaging. To clean the respirator, the faceseal 
should be wiped with a cloth moistened in warm soapy water 
(the water temperature should be below 40°C) and dried at room 
temperature. The product MUST NOT be immersed in water 
during cleaning. Alternatively, faceseal may be cleaned using the 
3M™ 105 Face Seal Cleaner. Always check that the product has 
not exceeded the use by date before use. 

Respiratory Protection is only effective if it is correctly selected, 
fitted and worn throughout the time when the wearer is exposed 
to respiratory contaminants.

3M offers advice on the selection of products, and training in the 
correct fitting and usage. 

For more information on 3M products and services please call the 
3M Health & Safety Helpline.

Materials

Component

Material

Facemask

Thermoplastic elastomer

Head Harness

Polypropylene

Head Strap

Polypropylene/cotton

Inhalation Valve

Polyisoprene

Exhalation Valve

Silicone Rubber

Gas and Vapour Filter Body

Activated Carbon

Particulate Filter Element

Polypropylene

Содержание 4000 Series

Страница 1: ...cord keeping Easy and secure fitting of neck strap and adjustment of head cradle Optional overspray guard prolongs the life of the particulate filter when paint spraying Maximum product weight of 320 grams Applications The 3M 4000 Series Reusable Half Face Masks come in a variety of different product options 3M 4251 FFA1P2 R D provides protection against organic vapours good warning properties and...

Страница 2: ...ation under Article 10 EC Type Examination has been issued for these products by INSPEC International Limited 56 Leslie Hough Way Salford Greater Manchester M6 6AJ UK Notified Body number 0194 Certification under Article 11 EC quality control has been issued by BSI Product Services Notified Body number 0086 Cleaning and Storage If the respirator is to be used for more than one shift it should be c...

Страница 3: ...cordance with respirator and filter user instruction leaflet 9 In case of intended use in explosive atmospheres contact 3M technical service 3M definition minimum 19 5 by volume oxygen Fitting Instructions Before assigning any respirator to be worn in a contaminated area we recommend that a qualitative or quantitative fit check be performed before entering the workplace Fitting instructions must b...

Страница 4: ...ou cannot achieve a proper fit do not enter the contaminated area See your supervisor Important Notice 3M does not accept liability of any kind be it direct or consequential including but not limited to loss of profits business and or goodwill arising from reliance upon any information herein provided by 3M The user is responsible for determining the suitability of the products for their intended ...

Отзывы: