background image

P

 14

P

 13

If you have a heat pump with 
Auxiliary heat, the new sequential 
staging will give you faster recovery 
from set backs. The thermostat can 
be configured for Electric aux or 
gas/oil aux heat (see installation). If 
the heat pump cannot maintain your
desired room temperature, the new 
system allows the Aux heat to help 
maintain your heat all the way to 
your desired room temperature.

When using a heat pump with Auxiliary heat, if the heat pump is not working, you can 
move the large jumper 3 from B (lower) HEAT PUMP position to the A (upper) AUX ONLY
position (reset is not necessary). The Auxiliary heat will then be your only source of heat.
When the heat pump is again operational, be sure to change jumper 3 back to the B
position as the Auxiliary heat is more expensive than the heat pump.

Heat Pump Features

     This thermostat can be used with all millivolt and 24VAC heating and cooling systems. 
It cannot be used with line voltage systems. This thermostat is digital and your desired 
heat or cool temperatures can be easily be set on the large touch screen with the 
UP/DOWN arrows.  A minimum 4 minute off time protects heating and cooling systems 
from damage. 

     
This thermostat uses a new 

technique called sequential 
staging for more comfort with 
faster reaction to requested 

temperature changes. 
     

3M-30 Features

HEAT PUMP/ 
AUX ONLY
Jumper

A

B

Содержание 3M-30

Страница 1: ...et Temperature Basic Screens The MODE SWITCH of the 3M 30 must be in the HEAT or the COOL position to access all control functions The 3M 30 Thermostat has 3 basic screens The HOME screen is displayed...

Страница 2: ...lter Timer set Chirp set Touch this to turn the audible chirp on or off Temperature Swing set Return HOME Set Program Day Touch this area to set the day of the week you want to program Target Temps fo...

Страница 3: ...ergy saving program chart below PG 6 All Days 70 o F 62 o F 70 o F 62 o F MORN 6 00am HEAT DAY 8 00am EVEN 6 00pm NITE 10 00pm All Days 78o F 85o F 78o F 82o F MORN 6 00am COOL DAY 8 00am EVEN 6 00pm...

Страница 4: ...to move the time selection forward or backward until it displays the desired time Touch and hold for faster time set Forward Backward Select the desired temperature Touch the UP temp Down temp arrows...

Страница 5: ...table target temp for the system to hold until you return and remove HOLD Return HOME Temp Up Temp Down arrows Touch these to raise and lower the manual override Target Temp Manual Override indicator...

Страница 6: ...ur new filter To leave the filter display touch HOME Lock Allows you to to prevent any changes in custom settings To Lock Level1 touch the LOCK icon on the MENU screen for 2 sec Level1 allows temporar...

Страница 7: ...not necessary The Auxiliary heat will then be your only source of heat When the heat pump is again operational be sure to change jumper 3 back to the B position as the Auxiliary heat is more expensive...

Страница 8: ...meter in your home you can adjust it Maximum calibration is 6 o To change the calibration With the switch MODE in HEAT or COOL Press the MENU button Press the Temp Up Temp Down arrows to adjust the te...

Отзывы: