*NCnn Country select
This command provides customers chose the country for
phone line regulation.
*NC40
Australia
*NC1
Austria
*NC2
Belgium
*NC3
Denmark
*NC4
Finland
*NC5
France
*NC6
Germany
*NC17 Greece
*NC10 Netherlands
*NC28 Iceland
*NC7
Ireland
*NC8
Italy
*NC29 Liechtenstein
*NC9 Luxembourg
*NC43 Japan
*NC26 Namibia
*NC11 Norway
*NC12 Portugal
*NC27 South Africa
*NC13 Spain
*NC14 Sweden
*NC15 Switzerland
*NC16 UK
*NC18 India
*NC19 Czech Republic
*NC20 Taiwan
*NC24 Poland
*NC25 Russia
*NC22 United States
*NC36 CTR 21 600 ohm
*NC37 CTR 21 Complex Impedance
Result Codes:
OK
ERROR
Otherwise
*Tn Trellis Coding Selection
*T0
Disables Trellis coding
*T1* Enables Trellis coding (Default)
Result Codes:
OK
n = 0,1
ERROR
Otherwise
*On Transmission Level Selection
*O0* Selects output level -11dBm (Default)
*O1
Selects output level -12dBm
*O2
Selects output level -13dBm
*O3
Selects output level -14dBm
*O4
Selects output level -15dBm
*O5 Selects output level -16dBm
*O6
Selects output level -17dBm
*O7
Selects output level -18dBm
*O8
Selects output level -19dBm
*O9
Selects output level -20dBm
*O10 Selects output level -21dBm
*O11 Selects output level -22dBm
*O12 Selects output level -23dBm
*O13 Selects output level -24dBm
*O14 Selects output level -25dBm
*O15 Selects output level -26dBm
Result Codes:
OK
n = 0 - 15
ERROR
Otherwise
\
Nn Error Control Mode Selection
This command determines the type of error control used
by the modem when sending or receiving data.
\
N0
Normal mode.
\
N1
Direct mode.
\
N2
MNP or disconnect mode. The modem attempts
to connect using MNP 2-4 error control
procedures. If this fails, the modem disconnects.
This is also known as MNP reliable mode.
\
N3
MNP, or buffer.
The modem attempts to connect using MNP 2-4
error control procedures. If this fails, the modem
will connect in Normal modem
\
N4
V.42 without ODP & ADP phase detection, MNP
or buffer.
\
N5*
V.42 with ODP & ADP phase detection, MNP, or
buffer (default).
The modem attempts to connect in V.42 error
control mode. If this fails, the modem attempts to
connect in MNP mode. If this fails, the modem
connects in buffer mode and continues operation.
This is also known as V.42/ MNP auto reliable
mode.
\N6
V.42 without ODP & ADP phase detection or
disconnect. The modem attempts to connect in
V.42 error control mode. If this fails, the call will
be disconnected.
\
N7
V.42 with ODP & ADP phase detection or
disconnect.
Result Codes:
OK
n = 0, 1, 2, 3, 4, 5, 6,7
ERROR
Otherwise
\
Vn Protocol Result Code
\V0*
Disable protocol result code appended to DCE
speed. (Default)
\
V1
Enable protocol result code appended to DCE
speed.
Result Codes:
OK
n = 0, 1
ERROR
Otherwise
%Cn Data Compression Control
This command determines the operation of V.42bis and
MNP class 5 data compression. Online changes do not
take effect until a disconnection occurs first.
%C0
V.42bis/ MNP 5 disabled. No data compression.
%C1*
V.42bis/ MNP 5 enabled. Data compression
enabled (Default).
Result Codes:
OK
n = 0, 1
ERROR
Otherwise
%Dn Blacklisting Controll
%D0
Disable blacklisting.
%D1*
Enable blacklisting. (Default)
Result Codes:
OK
n = 0, 1
ERROR
Otherwise
Содержание ILP 0001
Страница 13: ......
Страница 14: ......
Страница 16: ...ILP 0001 User s Manual AT Command Set ...
Страница 27: ... tt5 10 V17 14400 short train tt5 11 V17 14400 long train ...