3e–525C–3 Wireless Access Point
Chapter 2: Hardware Installation
18
29000171-001 A
3e–525C–3 Wireless Access Point
Chapter 2: Hardware Installation
29000171-001 A
19
! WARNING
Do not attempt to install any outdoor equipment dur-
ing hazardous conditions such as a thunderstorm,
where lightning could strike the equipment or installer.
Failure to follow this warning could result in injury or
death.
Earth Ground Connection
Attach the earth ground cable to the ring terminal attached to the
3e–525C–3's grounding stud. Make sure the ring terminal is against the
unit's metal case. The earth ground ring terminal should be the first con-
nection on the unit's grounding stud.
NOTE
: The cable used to connect to a proper earth ground must be
AWG 10 or heavier. This cable should be kept as short as possible.
Lighnting Arrestor Installation
Examine the lightning arrestors and remove and discard the following
items (if necessary). See figure below.
• Securing Nut
• Washer
• Ring Terminal (but retain the screw)
Securing Nut
Washer
Ring Terminal