3D Systems, Inc.
55
Fresh-Bin Diag Screen
From the
Diagnostics
screen, use the dial to highlight the menu item
Fresh-bin
diag
, and press the dial to select . For further diagnostics options refer to the section,
“Diagnostics Screen” on page 54
.
This screen displays the following status information:
•
Left door closed/open
: This indicates whether the left door for inputting fresh
material is open or closed .
•
Right door closed/open
: This indicates whether the right door for inputting fresh
material is open or closed .
•
Doors unlocked/locked
: Indicates whether or not the doors for inputting fresh
material are locked or unlocked .
•
Powder Level full/not full
: Indicates if the fresh material bin is full or not .
Used-Bin Diag Screen
From the
Diagnostics
screen, use the dial to highlight the menu item
Used-bin
diag
, and press the dial to select . For further diagnostics options refer to the section,
“Diagnostics Screen” on page 54
.
This screen displays the following status information:
•
Powder Level full/not full
: Indicates if the used material bin is full or not .
•
Gate valve open/closed
: Indicates if the gate valve for the used material bin is
opened or closed .
•
Transport level full/not full
: Indicates whether or not the transporter for the used
material is full or not .
•
Fluidizing air on/off
: Indicates whether or not the air responsible for fluidizing the
Blend-Bin Diag Screen
From the
Diagnostics
screen, use the dial to highlight the menu item
Blend-bin
diag
, and press the dial to select . For further diagnostics options refer to the section,
“Diagnostics Screen” on page 54
.
This screen displays the following status information:
•
Powder Level full/not full
: Indicates if the blended material bin is full or not .
•
Gate valve open/closed
: Indicates if the gate valve for the blended material bin
is opened or closed .
•
Transport level full/not full
: Indicates whether or not the transporter for the
blended material is full or not .
•
Fluidizing air on/off
: Indicates whether or not the air responsible for fluidizing
Fresh-bin diag
L door closed/open
R door closed/open
Doors unlocked/locked
Pwdr level full/not full
Gate valve open/closed
Tport level full/not full
Fluid air on/off
Tport air on/off
Weight
Pressure
Used-bin diag
Pwdr level full/not full
Gate valve open/closed
Tport level full/not full
Fluid air on/off
Tport air on/off
Pinch U->U closed/open
Pinch U->B closed/open
Weight
Pressure
Blend-bin diag
Pwdr level full/not full
Gate valve open/closed
Tport level full/not full
Fluid air on/off
Tport air on/off
Pinch B->B closed/open
Pinch B->PA closed/open
Pinch B->PB closed/open
Weight
Pressure
•
Gate valve open/closed
: Indicates if the gate valve for the fresh material bin is opened
or closed .
•
Transport level full/not full
: Indicates whether or not the transporter for the fresh mate-
rial is full or not .
•
Fluidizing air on/off
: Indicates whether or not the air responsible for fluidizing the material in the transporter is on or off.
•
Transporter air on/off
: Indicates whether or not the air responsible for transporting the material out of the transporter is on or off .
material in the transporter is on or off .
•
Transporter air on/off
: Indicates whether or not the air responsible for transporting the
material out of the transporter is on or off .
•
Weight
: Gives the weight of the material in the used bin .
the material in the transporter is on or off .
•
Transporter air on/off
: Indicates whether or not the air responsible for transporting the
material out of the transporter is on or off .
•
Weight
: Gives the weight of the material in the blended bin .
•
Pressure
: Gives the air pressure from the transporter .