3D Systems, Inc.
50
First line display may change based on MQC current status:
•
F B -> B indicates Full Cycle mode and Blended Bin recirculation
•
Other possible status messages:
•
R -> R Reclaimed bin recirculation
•
B -> PA Blended bin transporting to Printer A
•
B -> PB Blended bin transporting to Printer B
To toggle from Status screen to Main Control screen, quickly press and release control knob .
In opposite screen:
•
There are 2 liters in fresh bin
•
There are 4 liters in the recycled bin
•
There are 53 liters in blended powder bin
•
The MQC will not start another blend cycle unless:
•
The fresh bin level is greater than 19 liters
•
The recycled bin level is greater than 21 liters
•
The blended bin level is less than 80 liters
•
The sifter is idle and but if in use the output would be directed to Reclaimed bin
•
The cooling lid is idle but if in use N2 flow duration would be controlled by temperature probe
The amount of powder required in the Fresh and Reclaimed bins to start a blend will vary based on the current refresh percentage .
MQC Main Control Screen
•
The
Main Control Screen
allows the user to:
•
Navigate to the
Operational Mode
screen .
•
Load Fresh Powder
into the system (To do this the user must first scan the material RFID tag on the lid of the material container
across the RFID reader on the front panel of the MQC system . This will unlock the fresh bin access doors . The RFID tag material
type must match the material type currently in MQC
•
Start Cool Cycle
- Start the N2 flow to the Cooling lid (duration controlled either by temperature or time)
•
Change Sifter Mode
– allows user to select destination of the output from the sifter (reclaimed bin or external barrel or drum)
•
Setup/Service/Diag
– Navigate to submenu . (only the Setup screen is available to general users . Service and Diag screens are
only for use by 3D Systems Certified Technicians)
•
Activate Service
– Service RFID tag required
•
Clear Weight Error
- usage by operator for a clear bin weight tag to clear a bin weight error