2-4
Displaying and Maintaining RMON
To do…
Use the command…
Remarks
Display RMON statistics
display rmon statistics
[
interface-type
interface-number
|
unit unit-number
]
Display RMON history
information
display rmon history
[
interface-type
interface-number
|
unit
unit-number
]
Display RMON alarm
information
display rmon alarm
[
entry-number
]
Display extended RMON alarm
information
display rmon prialarm
[
prialarm-entry-number
]
Display RMON events
display rmon event
[
event-entry
]
Display RMON event logs
display rmon eventlog
[
event-entry
]
Available in any view
RMON Configuration Examples
Network requirements
z
As shown in
Figure 2-1
, the Switch to be tested is connected to a remote NMS through the Internet.
Ensure that the SNMP agents are correctly configured before performing RMON configuration.
z
Create an entry in the extended alarm table to monitor the information of statistics on the Ethernet
port, if the change rate of which exceeds the set threshold, the alarm events will be triggered.
Figure 2-1
Network diagram for RMON configuration
Console port
Switch
Internet
Network port
NMS
Configuration procedures
# Add the statistics entry numbered 1 to take statistics on GigabitEthernet 1/0/1.
<device> system-view
[device] interface GigabitEthernet 1/0/1
[device-GigabitEthernet1/0/1] rmon statistics 1
[device-GigabitEthernet1/0/1] quit
# Add the event entries numbered 1 and 2 to the event table, which will be triggered by the following
extended alarm.
[device] rmon event 1 log
[device] rmon event 2 trap 10.21.30.55
# Add an entry numbered 2 to the extended alarm table to allow the system to calculate the alarm
variables with the (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) formula to get the numbers of all
the oversize and undersize packets received by GigabitEthernet 1/0/1 that are in correct data format
and sample it in every 10 seconds. When the change ratio between samples reaches the rising
threshold of 50, event 1 is triggered; when the change ratio drops under the falling threshold, event 2 is
triggered.