Distinctive Ring Support
4-11
There are four ring patterns in common use:
These are graphical depictions of each ring pattern.
Commands
Example:
Sending
ATS70.0=1.3=1
to your modem enables the
recognition of ring types A and D only.
Ring
Description
A
1.2 to 2.0 seconds on, 4.0 seconds off.
B
0.8 second on, 0.4 second off, 0.8 second on, 4.0 seconds off.
C
0.4 second on, 0.2 second off, 0.4 second on, 0.2 second off, 0.8 second
on, 4.0 seconds off.
D
0.3 second on, 0.2 second off, 1.0 second on, 0.2 second off, 0.3 second
on, 4.0 seconds off.
For your modem to
Command
Enable recognition of Ring A
ATS70.0=1
Disable recognition of Ring A
ATS70.0=0
Enable recognition of Ring B
ATS70.1=1
Disable recognition of Ring B
ATS70.1=0
Enable recognition of Ring C
ATS70.2=1
Disable recognition of Ring C
ATS70.2=0
Enable recognition of Ring D
ATS70.3=1
Disable recognition of Ring D
ATS70.3=0
Содержание U.S. Robotics 56K Voice
Страница 1: ...http www 3com com 3Com OfficeConnect 56K Business Modem Command Reference Published January 1999...
Страница 14: ...4 ABOUT THIS GUIDE...
Страница 32: ...1 18 CHAPTER 1 CONNECTING TO YOUR ISP...
Страница 42: ...3 6 CHAPTER 3 MODES OF OPERATION...
Страница 64: ...7 4 CHAPTER 7 CONTROLLING EIA 232 SIGNALING...
Страница 72: ...8 8 CHAPTER 8 CONTROLLING DATA RATES...
Страница 80: ...9 8 CHAPTER 9 ACCESSING AND CONFIGURING THE BUSINESS MODEM REMOTELY...
Страница 96: ...11 6 CHAPTER 11 FLOW CONTROL...
Страница 108: ...12 12 CHAPTER 12 HANDSHAKING ERROR CONTROL DATA COMPRESSION AND THROUGHPUT...
Страница 112: ...13 4 CHAPTER 13 DISPLAYING QUERYING AND HELP SCREENS...
Страница 124: ...14 12 CHAPTER 14 TESTING THE CONNECTION...
Страница 132: ...15 8 CHAPTER 15 TROUBLESHOOTING...
Страница 162: ...B 14 APPENDIX B ALPHABETIC COMMAND SUMMARY...
Страница 168: ...C 6 APPENDIX C FLOW CONTROL TEMPLATE...
Страница 210: ...14 GLOSSARY...