![3Com U.S. Robotics 56K Voice Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/3com/u-s-robotics-56k-voice/u-s-robotics-56k-voice_command-reference-manual_3142187121.webp)
Testing the Business Modem using S-Resister 16
14-9
Testing the Business
Modem using
S-Resister 16
Register S16 is a bit-mapped register (See Appendix A,
S-Registers
, for
instructions for setting bit-mapped registers).
Earlier modems require bit 3 to be enabled to grant digital loopback
testing to a remote device. The Business Modem requires the &T4 setting
instead. To perform remote digital loopback testing with a modem that
does not use the &T test command, that modem should be set to S16=8.
Analog Loopback (AL)
S16=1D
To use the modem's Test Pattern (S16, bit 2) instead of typing your own
data, see RDL Testing Using a Built-in Test Pattern (S16=4).
1
Send
AT&M0&N3S14.0=0
to the modem to prepare for testing.
This command disables error control, fixes the connection rate at 2400
bps, and makes the Business Modem return to command mode when
you type
+++
.
2
Send
ATS16=1D
. The modem enters AL mode and sends a CONNECT
result code. The MR status light flashes.
3
Type data to the modem for it to transmit, loop to its receiver, and output
to the screen.
An alternative is to use the Test Pattern, described later.
4
Send the escape code,
+++
, and then
ATH
to end the test.
5
Send
AT&M4
, unless you used a reset command (ATZ or ATZ!).
For your modem to use
Use one of these command
Remote digital loopback with built-in test pattern
ATS16=4
or
ATS16.2=1
Remote digital loopback using keyboard data
ATS16=8
or
ATS16.3=1
Содержание U.S. Robotics 56K Voice
Страница 1: ...http www 3com com 3Com OfficeConnect 56K Business Modem Command Reference Published January 1999...
Страница 14: ...4 ABOUT THIS GUIDE...
Страница 32: ...1 18 CHAPTER 1 CONNECTING TO YOUR ISP...
Страница 42: ...3 6 CHAPTER 3 MODES OF OPERATION...
Страница 64: ...7 4 CHAPTER 7 CONTROLLING EIA 232 SIGNALING...
Страница 72: ...8 8 CHAPTER 8 CONTROLLING DATA RATES...
Страница 80: ...9 8 CHAPTER 9 ACCESSING AND CONFIGURING THE BUSINESS MODEM REMOTELY...
Страница 96: ...11 6 CHAPTER 11 FLOW CONTROL...
Страница 108: ...12 12 CHAPTER 12 HANDSHAKING ERROR CONTROL DATA COMPRESSION AND THROUGHPUT...
Страница 112: ...13 4 CHAPTER 13 DISPLAYING QUERYING AND HELP SCREENS...
Страница 124: ...14 12 CHAPTER 14 TESTING THE CONNECTION...
Страница 132: ...15 8 CHAPTER 15 TROUBLESHOOTING...
Страница 162: ...B 14 APPENDIX B ALPHABETIC COMMAND SUMMARY...
Страница 168: ...C 6 APPENDIX C FLOW CONTROL TEMPLATE...
Страница 210: ...14 GLOSSARY...