Running the AutoLink Program
3-3
1 Make a backup copy of the CONFIG.SYS file. Type:
copy config.sys config.old [Enter]
2 Edit the memory manager device statement in the
CONFIG.SYS file to exclude the memory range that
the 3C319 NIC uses.
The statement should be similar to the following:
where
X
stands for exclude, followed by the NIC’s
memory range. See
Chapter 5
,
“Configuring the
NIC Manually
,” for additional memory ranges.
Refer to your operating system manual for additional
instructions and information on using the memory
manager.
3 Save the CONFIG.SYS file and exit the text editor.
4 Reboot the PC.
Next, load the NetWare DOS ODI client driver by running
the AutoLink program, as described in the next section.
Running the AutoLink Program
The AutoLink program loads the NetWare DOS ODI client
driver and automatically configures the 3C319 NIC. To
run the AutoLink program, follow these steps:
1 Insert
TokenDisk
diskette #1 in the floppy drive
and type:
a: [Enter]
2 Type:
autolink [Enter]
The first time you use the installation software, the 3Com
software license appears.
DEVICE=C:\WINDOWS\EMM386.EXE NOEMS X=CC00-CDFF X=D800-DBFF