1-4
z
Allow the PCs of Organization 1 to access the external network through GigabitEthernet 1/0/1 of
Switch A.
z
Allow the PCs of Organization 2 to access the external network through GigabitEthernet 1/0/2 of
Switch A.
z
GigabitEthernet 1/0/1 and GigabitEthernet 1/0/2 belong to VLAN 1. The IP address of
VLAN-interface 1 is 202.10.20.200/24.
z
PCs of Organization 1 are isolated from those of Organization 2 on Layer 2.
Network diagram
Figure 1-3
Network diagram for combining access management and port isolation
Switch A
Switch B
GE1/0/1
PC1_1
PC1_2
PC1_20
Internet
202.10.20.1/24
~
202.10.20.20/24
Switch C
GE1/0/2
PC2_1
PC2_2
PC2_37
Organization 2
Organization 1
202.10.20.25/24
~
202.10.20.50/24
202.10.20.55/24
~
202.10.20.65/24
Vlan-int1
202.10.20.200/24
Configuration procedure
Perform the following configuration on Switch A.
For information about port isolation and the corresponding configuration, refer to the
Port Isolation
Operation
.
# Enable access management.
<Sysname> system-view
[Sysname] am enable
# Set the IP address of VLAN-interface 1 to 202.10.20.200/24.
[Sysname] interface Vlan-interface 1
[Sysname-Vlan-interface1] ip address 202.10.20.200 24
[Sysname-Vlan-interface1] quit
# Configure the access management IP address pool on GigabitEthernet 1/0/1.
[Sysname] interface GigabitEthernet 1/0/1
[Sysname-GigabitEthernet1/0/1] am ip-pool 202.10.20.1 20
# Add GigabitEthernet 1/0/1 to the port isolation group.
Содержание Switch 4800G PWR 24-Port
Страница 165: ...1 8 4 mac address es found on port GigabitEthernet1 0 2 ...
Страница 214: ...ii Displaying and Maintaining System Guard 4 1 ...
Страница 445: ...ii ...
Страница 727: ...i Table of Contents Appendix A Acronyms A 1 ...
Страница 730: ...A 3 VOD Video On Demand W WRR Weighted Round Robin X XID eXchange Identification XRN eXpandable Resilient Networking ...