2-14
To reduce the risk of being attacked by malicious users against opened socket and enhance switch
security, the Switch 4200G series Ethernet switches provide the following functions, so that a cluster
socket is opened only when it is needed:
z
Opening UDP port 40000 (used for cluster) only when the cluster function is implemented,
z
Closing UDP port 40000 at the same time when the cluster function is closed.
On member devices, the preceding functions are implemented as follows:
z
When you execute the
add-member
command on the management device to add a candidate
device to a cluster, the candidate device changes to a member device and its UDP port 40000 is
opened at the same time.
z
When you execute the
auto-build
command on the management device to have the system
automatically add candidate devices to a cluster, the candidate devices change to member devices
and their UDP port 40000 is opened at the same time.
z
When you execute the
administrator-address
command on a device, the device's UDP port
40000 is opened at the same time.
z
When you execute the
delete-member
command on the management device to remove a
member device from a cluster, the member device's UDP port 40000 is closed at the same time.
z
When you execute the
undo build
command on the management device to remove a cluster, UDP
port 40000 of all the member devices in the cluster is closed at the same time.
z
When you execute the
undo administrator-address
command on a member device, UDP port
40000 of the member device is closed at the same time.
Enabling NDP globally and on specific ports
Table 2-13
Enable NDP globally and on specific ports
Operation
Command
Description
Enter system view
system-view
—
Enable NDP globally
ndp enable
Required
In system view
ndp enable interface port-list
Enter
Ethernet
port view
interface interface-type
interface-number
Enable
NDP on
specified
ports
In
Ethernet
port view
Enable
NDP on
the port
ndp enable
Required
Use either
approach.
Enabling NTDP globally and on a specific port
Table 2-14
Enable NTDP globally and a specific port
Operation
Command
Description
Enter system view
system-view
—
Содержание Switch 4800G PWR 24-Port
Страница 165: ...1 8 4 mac address es found on port GigabitEthernet1 0 2 ...
Страница 214: ...ii Displaying and Maintaining System Guard 4 1 ...
Страница 445: ...ii ...
Страница 727: ...i Table of Contents Appendix A Acronyms A 1 ...
Страница 730: ...A 3 VOD Video On Demand W WRR Weighted Round Robin X XID eXchange Identification XRN eXpandable Resilient Networking ...