background image

Please read the following safety information carefully before
installing the

Baseline Hub

.

WARNING:

Installation and removal of the unit must be carried out by

qualified personnel only.

!

The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.

!

Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.

!

The appliance coupler (the connector to the unit and not the wall plug) must
have a configuration for mating with an EN60320/IEC320 appliance inlet.

!

The socket outlet must be near to the unit and easily accessible. You can only
remove power from the unit by disconnecting the power cord from the
outlet.

!

This unit operates under SELV (Safety Extra Low Voltage) conditions according
to IEC 60. The conditions are only maintained if the equipment to which it is
connected also operates under SELV conditions.

!

Only connect an

Advanced Redundant Power System (3C16070, 3C16071,

3C16071A or 3C16071B)

or

Redundant Power System (3C565047)

to the

Redundant Power System

socket.

France and Peru only

This unit cannot be powered from IT

supplies. If your supplies are of IT type, this

unit must be powered by 230V (2P+T) via an isolation transformer ratio 1:1, with the
secondary connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Power Cord Set

This must be approved for the country where it will be used. e.g.

Veuillez lire à fond l'information de la sécurité suivante avant
d'installer le

Baseline Hub

.

AVERTISSEMENT:

L’installation et la dépose de ce groupe doivent être

confiés à un personnel qualifié.

!

Ne branchez pas votre appareil sur une prise secteur (alimentation électrique)
lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).

!

Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse)
afin de respecter les normes internationales de sécurité.

!

Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale)
doit respecter une configuration qui permet un branchement sur une entrée
d’appareil EN60320/IEC 320.

!

La prise secteur doit se trouver à proximité de l’appareil et son accès doit être
facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son
cordon électrique au niveau de cette prise.

!

L’appareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme IEC60950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.

!

Branchez uniquement un

Advanced Redundant Power System (3C16070,

3C16071, 3C16071A ou 3C16071B)

ou un

Redundant Power System

(3C565047)

sur la prise femelle du

Redundant Power System

.

France et Pérou uniquement:

Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos
alimentations sont du type impédance à la terre, ce groupe doit être alimenté par
une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport
1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec
raccordement direct à la terre (masse).

Cordon électrique

Il doit être agréé dans le pays d’utilisation.

Bitte unbedingt vor dem Einbauen des

Baseline Hub

Einheit die fol-

genden Sicherheitsanweisungen durchlesen.

WARNUNG:

Die Installation und der Ausbau des Geräts darf nur durch

Fachpersonal erfolgen.

!

Das Gerät nicht an eine Wechselstromsteckdose anschließen, die nicht
geerdet ist.

!

Das Gerät muß an eine geerdete Steckdose angeschlossen werden, die die
internationalen Sicherheitsnormen erfüllt.

!

Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß eine passende Konfiguration für einen
Geräteeingang gemäß EN60320/IEC320 haben.

!

Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein.
Die Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.

!

Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60. Diese Bedingungen sind nur
gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.

!

Nur ein

Advanced Redundant Power System (3C16070, 3C16071,3C16071A

oder

3C16071B)

oder

Redundant Power System (3C565047)

an den

Redundant Power System

Anschluß anschließen.

Stromkabel

Dies muss von dem Land, in dem es benutzt wird geprüft werden:

S

AFETY

I

NFORMATION

U.S.A. and
Canada

The cord set must be UL-approved and CSA certified.

The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor

The cord set must have a rated current capacity of at least
10A.

The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.

Denmark

The supply plug must comply with Section 107-2-D1,
Standard DK2-1a or DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011.

UK

The supply plug must comply with BS1363 (3-pin 13-amp)
and be fitted with a 5A fuse which complies with BS1362.

The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”)

The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).

L’

INFORMATION DE

S

ÉCURITÉ

I

MPORTANTE

Etats-Unis
et Canada

Le cordon doit avoir reçu l’homologation des UL et un
certificat de la CSA.

Le cordon souple doit respecter, à titre minimum, les
spécifications suivantes:
calibre 18 AWG
type SV ou SJ
à 3 conducteurs

Le cordon doit être en mesure d’acheminer un courant
nominal d’au moins 10 A.

La prise femelle de branchement doit être du type à mise à
la terre (mise à la masse) et respecter la configuration NEMA
5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).

Danemark

La prise mâle d’alimentation doit respecter la section 107-2
D1 de la norme DK2 1a ou DK2 5a.

Suisse

La prise mâle d’alimentation doit respecter la norme SEV/ASE
1011.

Europe

La prise secteur doit être conforme aux normes CEE 7/7
(“SCHUKO”)

LE cordon secteur doit porter la mention <HAR> ou
<BASEC> et doit être de type HO3VVF3GO.75 (minimum).

W

ICHTIGE

S

ICHERHEITSINFORMATIONEN

Schweiz

Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen
einhalten.

Europe

Das Netzkabel muß vom Typ HO3VVF3GO.75
(Mindestanforderung) sein und die Aufschrift <HAR> oder
<BASEC> tragen.

Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).

4

Содержание Switch 4800G PWR 24-Port

Страница 1: ...s a single IEEE 802 3 Ethernet repeater hub there can be a maximum of four Baseline Hubs between any two pieces of Data Terminal Equipment DTE workstations or other equipment on the same network The B...

Страница 2: ...DI ports to connect to other repeaters using a normal straight through TP cable To connect two Baseline Hubs connect port 12 or 24 on unit 1 to any port on unit 2 Ensure that the MDI switch on unit 1...

Страница 3: ...lat surface or stacked with another SuperStack 3 product of the same dimensions Use the two reduced height pads and two of the standard height pads if the unit is to be stacked on a SuperStack 3 unit...

Страница 4: ...masse Cordon lectrique Il doit tre agr dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Baseline Hub Einheit die fol genden Sicherheitsanweisungen durchlesen WARNUNG Die Installation u...

Страница 5: ...re returning the unit product number and serial number printed on a label on the back of the unit a brief description of the fault When returning any equipment to your supplier ensure that the equip m...

Страница 6: ...y if Customer provides a purchase order number credit card number or other method of payment acceptable to 3Com to be used if 3Com needs to charge Customer for the replacement as explained below The r...

Страница 7: ...olve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment...

Страница 8: ...f their respective holders General Environmental Statement It is the policy of 3Com Corporation to be environmentally friendly in all operations To uphold our policy we are committed to Establishing e...

Отзывы: