Known Problems
19
To create the VLAN, clear the Mobility Domain config-
uration from the switch, create the VLAN, then con-
figure the Mobility Domain again.
The set port poe
port-list
disable command
might not disable PoE. (17624)
On rare occasions (one in about 20 times), the
set
port poe
port-list
disable
command might not dis-
able PoE on the specified ports.
To determine whether PoE has really been disabled,
type the
display port poe
command. If the Draw
field lists a number instead of
off
, PoE is still enabled.
Try entering the
set port poe
port-list
enable
com-
mand, followed by the
set port poe
port-list
disable
command.
Display of WX4400 serial number for licensing
contains only the last 6 digits. (18398)
Port group causes harmless error message to be
displayed during startup. (18333)
If a port group is created and assigned to a VLAN, an
error message is displayed while the switch is booting
up whenever the switch is reset or power cycled.
Below is an example of the error message. This
applies to both MX1200 and MX4400.
Example:
Starting supervisor 3.0.3.0_110304_WX1200 ...
.......SPAN Nov 05 07:01:44.073135 ERROR
SPAN_VLAN_ERR: span_port_change, port= 0 does
not exist
This message can be safely ignored.
Harmless
botched superblock
messages during
startup. (18564)
When you boot the switch, the startup messages
include lines such as the following:
Checking for botched superblock
upgrades:msysioctl() 0x40386d02
...
msysioctl() 0x40386d02
done.
These messages do not indicate a problem and can be
safely ignored.
Switching and Port Issues
Autonegotiation with a 3Com switch that
supports Smart Auto-Sensing may result in a
10Mbps link. (18325)
If a WX1200 switch is attached to a 3Com switch that
supports Smart Auto-Sensing, and autonegotiation is
enabled at both ends of the link, the connection may
be down-rated to a 10 MBPs full-duplex link on initial
boot-up of the WX1200.
To resolve this issue, restrict the advertised capabilities
of the link partner on the SAS-enabled switch or dis-
able SAS on the switch.
Router redundancy protocol on intermediary
devices between WX switches in a Mobility