Maintenance and Repair
3-15
Figure 3-15
Installing a Second Power Supply in the Extended Chassis
Figure 3-16
Connecting the Power Cord to the Second Power Supply
DIAGNOSTIC
®
CEC
DIAGNOSTIC
®
CEC
Loosen retaining screws
on filler panel and
remove panel.
Tighten captive
retaining screw.
c
d
b
Disengage plunger
and slide power supply
into chassis. Press firmly
to engage connectors.
Filler panel
Spring-loaded plunger
Thread power cord through hole in
sheet metal as shown, and connect
to the power supply.
Secure cord behind strain-relief washer.
f
e
CONSOLE
AUXILIARY
DIAGNOSTIC
4
3
2
1
SELF TEST
CPU ACT
PKT FWD
STATUS
®
CEC
A
B
C
A
B
C
D
D
E
F
E
F
ETHERNET 6-PORT 10BASE-T
Sheet metal with
cut-out for power cord
Strain-relief
washer
(see detail)
Second power cord
Detail
Strain-relief
washer
Power supply