background image

4

Power LED

The Power LED shows the power status of the Switch:

5

Self-adhesive Pads

The unit is supplied with four self-adhesive rubber pads.

You do not need to apply the pads if you intend to rack 
mount the unit.

If the unit is to be part of a free standing stack, apply the pads to 
each marked corner area on the underside of the unit. Place the 
unit on top of the lower unit, ensuring that the pads locate with 
the recesses of the lower unit.

Rear Panel Connections

6

Power Supply

The Switch automatically adjusts to the supply voltage. Only use 
the power cord that is supplied with the Switch.

Positioning the Switch

CAUTION: 

If installing the Switch in a stack of different 

size Baseline units, the smaller units must be installed 
above the larger ones. Do not have a free-standing stack 
of more than six units.

CAUTION: 

Please read the following safety information 

carefully before installing the Switch.

AVERTISSEMENT: 

Veuillez lire à fond l'information de la 

sécurité suivante avant d'installer le Switch.

WARNUNG: 

Bitte unbedingt vor dem Einbauen des 

Switches die folgenden Sicherheitsanweisungen durchle-
sen.

ATTENZIONE: 

Vi preghiamo prima di leggere con attenzi-

one tutte le informazioni concernenti l'installazione 
dell'interruttore.

When deciding where to position the Switch ensure that:

„

It is accessible and cables can be connected easily.

„

Cabling is away from sources of electrical noise such as 
radios, transmitters and broadband amplifiers, and away from 
power lines and fluorescent lighting fixtures.

„

The Switch is situated away from sources of electrically 
conductive dust, for example laser printers.

„

The AC supply used by the Switch is separate to those used 
by units that generate high levels of AC noise, for example air 
conditioning units and laser printers.

„

Water or moisture cannot enter the case of the unit.

„

Air flow around the unit and through the vents in the side of 
the case is not restricted (3Com recommends that you 
provide a minimum of 25 mm (1 in.) clearance).

To prolong the operational life of your units:

„

Never stack units more than six high if free-standing, and 
ensure that cables are supported so that they do not cause 
the stack to fall over.

„

Do not place objects on top of any unit or stack.

„

Do not obstruct any vents at the sides of the case.

Rack Mounting

The Switch can be mounted in a 19-inch equipment rack using 
the Mounting Kit. Refer to “Mounting Kit Instructions” on 
page 5.

Power Up

Use the following sequence to power up the Switch:

1

Check the network connections and cables.

2

Connect the power supply cable to the appropriate power 
socket on the rear panel of the unit; refer to 

6

 

Power 

Supply

.

3

Connect the plug to the power supply outlet socket and 
switch on the power supply at the socket.

When the switch is powered on, the Power LED should be lit on 
green. If it is not, refer to 

Power LED

.

Spot Checks

At frequent intervals you should visually check the Switch. Regular 
checks can give you an early warning of a possible failure; any 
problems can then be attended to when there will be least effect 
on users. Check that all external cabling connections are secure 
and that no cables are pulled taut.

If you experience any problems operating the Switch, refer to “Prob-
lem Solving” on page 3.

Refer to the information about LEDs given earlier in this guide to 
see if the problem can be identified and rectified. Here are some 
common problems that can occur:

Link Status LED not lit for a port that has a connection.

 

There is a problem with this connection. Check that:

„

The device being connected to is powered on and operating 
correctly.

„

The cable is connected at both ends.

„

The cable is not damaged.

„

If the connection is to a workstation, that the workstation’s 
network interface is installed and configured correctly.

All ports appear to show continual activity.

 There may be 

broadcast storms on the network.

Remove port connections one at a time, waiting a few seconds 
between each port. If the LEDs go off after disconnection, the 
device that was connected to that port is introducing an excessive 
amount of broadcast frames to the network (some pieces of net-
work equipment operate by sending out broadcast frames regu-
larly). Refer to the documentation that accompanies the device for 
information on disabling the broadcast operation.

If the problem persists and the unit still does not operate success-
fully, contact your supplier. Include the product number and serial 
number (printed on a label supplied with the unit) as well as a 
brief description of the fault.

Status

Meaning

On Green

The unit is powered on and ready for use.

Off

The unit is not receiving power:

Check the power cord is connected correctly.

If the unit still does not operate, contact your supplier.

I

NSTALLING

 

THE

 S

WITCH

!

!
!
!

!

P

ROBLEM

 S

OLVING

 

3

Содержание Baseline 2016

Страница 1: ...witch is suited for office use where it can be free standing or rack mounted in a wiring closet or equipment room The Switch comes with One power cord for use with the Switch Four self adhesive rubber pads One mounting kit The Switch is powered from the AC mains supply The Switch provides high performance switched connections to 10 Mbps and 100 Mbps hubs servers and workstations that require a ded...

Страница 2: ...e Switch use Category 5 unshielded or shielded screened 100 Ohm TP cable or Category 3 cable for a 10 Mbps connection The maximum length of cable for each connection is 100m 328ft Connect one end of the cable to an RJ 45 port on the Switch and the other end to the appropriate RJ 45 port on the connecting device Each port on the Switch is auto negotiating its speed and duplex mode half duplex or fu...

Страница 3: ...e Rack Mounting The Switch can be mounted in a 19 inch equipment rack using the Mounting Kit Refer to Mounting Kit Instructions on page 5 Power Up Use the following sequence to power up the Switch 1 Check the network connections and cables 2 Connect the power supply cable to the appropriate power socket on the rear panel of the unit refer to 6 Power Supply 3 Connect the plug to the power supply ou...

Страница 4: ...don électrique Il doit être agréé dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Wenn der Switch 2016 2024 mit anderen 3Com Hubs oder Switch gestackt werden soll müssen grössere Geräte unter den schmaleren Hubs eingebaut werden Das Gerät ...

Страница 5: ...guidelines given in Positioning the Switch on page 3 Rack Mounting the Units The Switch is 1U high and will fit a standard 19 inch rack CAUTION Disconnect all cables from the unit before continuing Remove the self adhesive pads from the underside of unit if already fitted 1 Place the unit the right way up on a hard flat surface with the front facing towards you 2 Locate a mounting bracket over the...

Страница 6: ...du Canada VCCI Statement 3Com offers product registration case management and repair services through eSupport 3com com You must have a user name and password to access these services which are described in this appendix Register Your Product to Gain Service Benefits To take advantage of warranty and other service benefits you must first register your product at http eSupport 3com com 3Com eSuppor...

Страница 7: ...ber RMA by FAX using this number 61 2 9937 5048 or send an email at this email address ap_rma_request 3com com Europe Middle East and Africa Telephone Technical Support and Repair From anywhere in these regions not listed below call 44 1442 435529 From the following countries call the appropriate number Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy 0800 297 468 0800 7...

Страница 8: ...py please contact 3Com and a copy will be provided to you Unless otherwise indicated 3Com registered trademarks are registered in the United States and may or may not be registered in other countries 3Com and the 3Com logo are registered trademarks of 3Com Corporation Other brand and product names may be registered trademarks or trademarks of their respective holders General Environmental Statemen...

Отзывы: