5-11
You can use the
display oam link-event
command to display the statistics about Ethernet OAM link
events and use the
display oam critical-event
command to display the Ethernet OAM configuration
information. For example:
# Display the statistics of Ethernet OAM critical link events on all the ports of Device A.
[DeviceA] display oam critical-event
Port : GigabitEthernet1/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault :0 Dying Gasp : 0 Critical Event : 0
According to the above output information, no critical link event occurred on the link between Device A
and Device B.
# Display Ethernet OAM link event statistics of the remote end of Device B.
[DeviceB] display oam link-event remote
Port :GigabitEthernet1/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp : 5789 Errored FrameWindow : 10(100ms)
Errored Frame Threshold : 1 Errored Frame : 3
Error Running Total : 35 Event Running Total : 17
The above information indicates that 35 errors occurred since Ethernet OAM is enabled on Device A,
17 of which are caused by error frames. The link is instable.
Содержание 4510G
Страница 502: ...4 8 ...
Страница 1010: ...18 6 000f e235 dc71 1 Config static GigabitEthernet 1 0 1 NOAGED 1 mac address es found ...