4-37
With the TC-BPDU guard function, you can set the maximum number of immediate forwarding address
entry flushes that the switch can perform within a certain period of time after receiving the first
TC-BPDU. For TC-BPDUs received in excess of the limit, the switch performs forwarding address
entry flush only when the time period expires. This prevents frequent flushing of forwarding address
entries.
Follow these steps to enable TC-BPDU guard:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enable the TC-BPDU guard
function
stp tc-protection enable
Optional
Enabled by default
Configure the maximum
number of forwarding address
entry flushes that the device
can perform within a specific
time period after it receives the
first TC-BPDU
stp tc-protection threshold
number
Optional
6 by default
We recommend that you keep this feature enabled.
Enabling BPDU Dropping
In a STP-enabled network, some users may send BPDU packets to the switch continuously in order to
destroy the network. When a switch receives the BPDU packets, it will forward them to other switches.
As a result, STP calculation is performed repeatedly, which may occupy too much CPU of the switches
or cause errors in the protocol state of the BPDU packets.
In order to avoid this problem, you can enable BPDU dropping on Ethernet ports. Once the function is
enabled on a port, the port will not receive or forward any BPDU packets. In this way, the switch is
protected against the BPDU packet attacks so that the STP calculation is assured to be right.
Follow these steps to enable BPDU dropping:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enter Ethernet
interface view
or Layer-2
aggregate
interface view
interface interface-type
interface-number
Enter
interface view
or port group
view
Enter port
group view
port-group manual
port-group-name
Required
Use either command.
Configurations made in
interface view will take effect
on the current port only;
configurations made in port
group view will take effect on
all ports in the port group.
Enable BPDU dropping for the
port(s)
bpdu-drop any
Required
Disabled by default