86
C
HAPTER
6: U
PGRADING
S
OFTWARE
Now please start transfer file with XMODEM protocol
If you want to exit, Press <Ctrl+X>
Loading...CCCCCCCCCCCCCCCCCCCCCCCCCCCCC
5
As the file is downloading, start the XModem send file process with
terminal emulation software, such as Microsoft Hyperterminal.
When the download is complete, the following information is displayed:
Please input the file attribute (main/backup/none):none
done!
6
Repeat steps 1 to 5 for each of the remaining files.
Bootrom Upgrade
This section describes how to indicate which file the Switch is to boot
from once the software has been loaded.
1
From the Boot menu, select option 2 to display the following:
Select applicaton file to boot:
1. set application file to boot
2. set configuration files
3. set web files
0. return
Enter your choice (0-3):
2
Select option 2 to display a file list similar to the following:
Boot menu choice: 2
Free Space: 10491904 bytes
The current application file is s3n03_01_00s168.app
(*)-with main attribute;(b)-with backup attribute
(*b)-with both main and backup attribute
Please input the file number to change:
An asterisk (*) indicates the current main boot file.
A similar screen will be displayed for the configuration files and the web
files.
In each case, the file is given the attribute “main” or “backup”
File Number
File Size(bytes) File Name
====================================================
1(*)
4649088
s3n03_01_00s168.app
Содержание 3CR17561-91-US - Switch 4500 26PORT Managed 24 10/100 2 Gbe Stackable...
Страница 8: ......
Страница 62: ...62 CHAPTER 3 SETTING UP FOR MANAGEMENT...
Страница 74: ...74 CHAPTER 5 PROBLEM SOLVING...
Страница 90: ...90 CHAPTER 6 UPGRADING SOFTWARE...
Страница 114: ...114 APPENDIX B PIN OUTS...
Страница 120: ...120 APPENDIX C TECHNICAL SPECIFICATIONS...
Страница 128: ......