2-4
C
HAPTER
2: T
ROUBLESHOOTING
AND
R
EPLACING
THE
DPE M
ODULE
Replacing the
DPE Module
To replace the DPE module, follow these steps. You will need a small, flatblade
screwdriver.
Although it is not required, 3Com recommends that you turn off the system
before you remove and reinstall a DPE module.
1
Prevent ESD-related damage to the DPE module by following the ESD guidelines
presented in Chapter 1.
2
Disconnect any cables, if necessary.
3
Remove the DPE module from the chassis.
a
Loosen the two captive screws with the flathead screwdriver.
b
Press outward firmly and evenly on the ejector tabs.
The DPE module will eject from the slot.
4
Install the new DPE module by following the procedure in Chapter 1.
When you replace the DPE module, the firmware parameters that were
previously configured by the SysconF command in the software are not
automatically updated to the FPROM of the replacement DPE module. You must
reconfigure these parameters. Refer to the software guide for configuration
information.