If auto-negotiation is disabled, all the Switch ports are configured as
MDIX (cross-over). If you want to make a connection to another MDIX
port, you need a
cross-over
cable. Many ports on workstations and
servers are configured as MDI (straight-through). If you want to make a
connection to an MDI port, you need to use a standard
straight-through
cable. See
Table 7
.
3Com recommends that you use Category 5 twisted pair cable — the
maximum segment length for this type of cable is 100 m (328 ft).
CAUTION:
If you want to install the Switch using a Category 5E or
Category 6 cable, 3Com recommends that you briefly connect the cable
to a grounded port before connecting network equipment. If you do not,
the cables Electrostatic Discharge (ESD) may damage the Switch's port.
You can create a grounded port by connecting all wires at one end of a
UTP cable to an earth ground point, and the other end to a female RJ-45
connector located, for example, on a Switch rack or patch panel. The
RJ-45 connector is now a grounded port.
Table 7
Cables required to connect the Switch 4200 Family to other devices if
auto-negotiation is disabled
Choosing the correct
Fiber cables
Choose from the following cable options:
■
The 1000BASE-SX ports can be connected to multimode fiber cables
only.
■
The 1000BASE-LX and LH70 GBIC ports use multimode or
single-mode fiber optic cables.
For detailed information on fiber cable specifications, refer to the
SuperStack 3 Implementation Guide that accompanies your Switch.
Cross-over Cable
Straight-through Cable
Switch to Switch
(MDIX to MDIX)
✓
✕
Switch to Hub
(MDIX to MDIX)
✓
✕
Switch to PC (NIC)
(MDIX to MDI)
✕
✓
DUA1730-0AAA04.book Page 26 Thursday, November 17, 2005 2:59 PM
Содержание 3C17304A
Страница 6: ...DUA1730 0AAA04 book Page 6 Thursday November 17 2005 2 59 PM ...
Страница 30: ...30 CHAPTER 2 INSTALLING THE SWITCH DUA1730 0AAA04 book Page 30 Thursday November 17 2005 2 59 PM ...
Страница 52: ...52 CHAPTER 3 SETTING UP FOR MANAGEMENT DUA1730 0AAA04 book Page 52 Thursday November 17 2005 2 59 PM ...
Страница 58: ...58 CHAPTER 4 PROBLEM SOLVING DUA1730 0AAA04 book Page 58 Thursday November 17 2005 2 59 PM ...
Страница 70: ...70 APPENDIX B PIN OUTS DUA1730 0AAA04 book Page 70 Thursday November 17 2005 2 59 PM ...
Страница 80: ...80 APPENDIX D OBTAINING SUPPORT FOR YOUR PRODUCT DUA1730 0AAA04 book Page 80 Thursday November 17 2005 2 59 PM ...
Страница 84: ...DUA1730 0AAA04 book Page 84 Thursday November 17 2005 2 59 PM ...