Compression

If fewer than 30 compressions per cycle are made, the remainder will be allocated 0 
points. If more than 30 compressions per cycle are made, the additional compressi-
ons will not be assessed.

Compression frequency

If fewer than 30 compressions per cycle are made, only the completed compressions will be counted. If more than 30 
compressions per cycle are made, the additional compressions will not be assessed. The BPM values can only be shown 
after the first 2 compressions; otherwise 0 is shown. An average compression frequency is given for all compressions 
made.

Volumen

If fewer than 2 ventilations per cycle are made, the remainder will be allocated 0 points.
If more than 2 ventilations per cycle are made, the additional ventilations will not be assessed.

Pressure

If fewer than 2 ventilations per cycle are made, the remainder will be allocated 0 points.
If more than 2 ventilations per cycle are made, the additional ventilations will not be assessed.

green

in mm

in %

lower 
limit

>=50

>=83

upper 
limit

lower yellow

green

upper yellow

in BPM

in BPM

in BPM

lower limit

>=85

>=95

>105

upper limit

<95

<=105

<115

lower orange

lower yellow

green

upper yellow

upper orange

in ml/s

in %

in ml/s

in %

in ml/s

in %

in ml/s

in %

in ml/s

in %

lower limit

>=360

>=45

>=384

>=48

>=464

>=58

>608

>76

>=624

>=78

upper limit

<384

<48

<464

<58

<=608

<=76

<624

<78

<664

<83

lower orange

lower yellow

green

upper yellow

in cm H²O

in %

in cm H²O

in %

in cm H²O

in %

in cm H²O

in %

lower limit

>=10,56

>=48

>=12,54

>=57

>=14,3

>=65

>18,7

>85

upper limit

<12,54

<57

<14,3

<65

<=18,7

<=85

<=19,14

<=87

11

Содержание CPRLilly P70/1

Страница 1: ...CPRLilly P70 1017772 CPRLillyPRO P71 1017773 CPRLilly P70 1 1017774 CPRLillyPRO P71 1 1017775 1...

Страница 2: ...ntents 3 Quick introduction 4 Assembly start up and use 5 Simulations 6 Medical procedures 14 General safety instructions 16 FAQ 16 Maintenance and care 17 Replacement parts list 18 Technical data 19...

Страница 3: ...esuscitator ventilation is possible Realistic thoracic spring force and the required compression depth of 5 cm prepare the trainee for a situation with a real person A sound indicates that the require...

Страница 4: ...Quick Introduction 4 3B Scientific GmbH Rudorffweg 8 21031 Hamburg www 3bscientific com P70 CPRLilly P70 1 CPRLilly P71 CPRLillyPRO P71 1 CPRLillyPRO...

Страница 5: ...attery is fully charged Version P71 To avoid getting moisture into the inner circulation respiration may only be carried out when a throat bag has been inserted The throat bag should not be changed in...

Страница 6: ...If you intend to not use the device for an extended period charge the battery up completely until the LED flashes orange slowly Changing the battery The CPRLillyPRO has a very long life NiMH battery...

Страница 7: ...initial set up the app is automtically set to English Once the tablet has booted up the select dialogue box for the language of the application software is displayed on the touch sensitive screen To c...

Страница 8: ...simulation 3 3 Setting up removing a Bluetooth connection To connect another CPRLillyPRO Bluetooth can be deleted or set up again via the Settings function Only one CPRLillyPRO can be connected to the...

Страница 9: ...9...

Страница 10: ...ing the graphs 3 5 Exporting the data It is only possible to export data if the CPRLillyPRO is switched off and or the Bluetooth connection has been deactivated If CPRLillyPRO is connected the Print i...

Страница 11: ...located 0 points If more than 2 ventilations per cycle are made the additional ventilations will not be assessed Pressure If fewer than 2 ventilations per cycle are made the remainder will be allocate...

Страница 12: ...ssment may show a yellow symbol for the head tilt regardless of the mean over the simulation round red yellow green 50 50 80 Hand placement Depending on the compressions Richtig green wrong red Instea...

Страница 13: ...ablet If you have a P70 please connect two squeeze balls to the connectors for eye blinking and pulse By compressing the balls you can control the pulse and eye blinking as a trainer To control the pu...

Страница 14: ...mouth of the CPRLilly or the CPRLillyPRO Even semi liquid foreign bodies such as shaving foams can and should be introduced for practice purposes They can then be thrown away with the throat bag Impo...

Страница 15: ...the silence button You can find this in the simulator window if the teaching mode has been activated What do the colours on the LED button mean green light The CPRLillyPRO is switched on and ready fo...

Страница 16: ...ays airbag also ensure that using the device is especially hygienic Please do not use any harsh chemicals for cleaning because they can damage the model materials The upper skin of the CPRLilly or the...

Страница 17: ...Throat bag pack of 50 1017743 Throat bag pack of 100 1017744 Carry bag 1017746 Tracksuit top 1013678 Resuscitator 1017747 Torso skin light 1017766 Torso skin dark 1017748 Bag clip 1017749 Lower jaw 1...

Страница 18: ...evice class III Operating conditions CPRLilly and CPRLillyPRO are splash proof protection class IP 45 Operating temperature 10 C to 40 C Storage temperature 20 C to 60 C The plastics used meet the req...

Страница 19: ...i d e g r o u p o f c o m p a n i e s 3B Scientific P70 1017772 P70 1 1017774 P71 1017773 P71 1 1017775 v1 1 08 2015 Copyright for instruction manual and design of product 2015 3B Scientific GmbH Hamb...

Отзывы:

Похожие инструкции для CPRLilly P70/1