3. Technical data 

Display: 

Scales: 

0 … 10, linear 
0 … 3, linear 

Scale length: 

160 mm 

Pointer deflection: 

0…90° 

Electrical  
zero-point offset: 

in all DC ranges 

 

Measurements: 

Voltage ranges: 

0.1/ 0.3/ 1/ 3/ 10/ 30/ 
100/ 300/ 600 V AC/DC 

Current ranges: 

0.1/ 0.3/ 1/ 3/ 10/ 30/ 
100/ 300 mA AC/DC 
1/ 3/ 10 A AC/DC 

Input resistance: 

1 MΩ AC/DC 

Voltage drop when 
measuring current: 

100 mV approx. AC/DC 

 

Reference conditions: 

Ambient temperature:  23 °C 

Operating alignment: 

Vertical 

Signal form: 

Sine (1% max. discrep-
ancy) 

Peak factor: 

2  

Frequency range: 

40 Hz … 50 Hz … 5 kHz 

 

Accuracy (at reference conditions): 

DC quantities: 

Class 2 

DC with  
zero-point offset: 

Class 5 

AC quantities: 

Class 3 

 

Extended frequency range (class 10): 

– 600 V: 

40 Hz 

… 50 Hz … 40 kHz 

0,3 

– 1 V: 

40 Hz 

… 50 Hz … 10 kHz 

0,3 

– 3000 mA: 

40 Hz 

… 50 Hz … 40 kHz 

10 A: 

40 Hz 

… 50 Hz … 40 kHz 

 

Resistance, conductance, impedance, admit-
tance 

These  quantities  can  be  determined  by  forming 
various quotients involving “simultaneous meas-
urements” of current and voltage. 

R

 = 

U

 / 

I

below 

1 mΩ … above 10 MΩ 

S

 = 

I

 / 

U

below 

1 µS … above 30 S 

Z

 = 

U

 / I: 

below 

1 mΩ … above 10 MΩ,  

40 Hz … 40 kHz 

Y

 = 

I

 / 

U

below 

1  µS  …  above  30  S,  

40 Hz … 40 kHz 

Overload protection: 

Voltage ranges: 

600 V long-term in all 

 

voltage ranges 

Current ranges: 

10 A of long-term load-
ing in 3-A and 10-A 
ranges 

 

Electrical safety: 

Safety specifications: 

EN 61010-1 

Measuring category: 

CAT II: 600 V 

Contamination level: 

Protection type: 

IP20 

Connectors: 

4-mm safety sockets 

 

Protection: 

Fuses: 

2x FF 10 A/600 V  
(10 x 38 mm) 

Breaking capacity:  

at least 10 kA 

3B order number: 

5008564 

 

Power supply: 

Battery: 

1x 1.5 V, AA IEC LR6  

Automatic cut-off after:   45 min ± 10 min 

 

Electromagnetic compatibility: 

Interference emission:  EN 55011:2009 

Interference resistance: EN 61326-1:2013 

 

Operating conditions: 

Ambient temperature:  5 °C ... 23 °C 

… 40°C 

Storage temperature:   -

20 … 70°C 

Relative humidity: 

<85% with no conden-
sation 

 

General data: 

Shock test: 

max. 147 m/s² 

Height: 

297 mm 

Dimensions: 

259 x 297 x 125 mm

3

 

Weight: 

1,7 kg approx. 

 
 
 
 
 
 
 
 
 

Содержание 1017895

Страница 1: ... and au tho rised for making measurements in circuits directly connected to the low voltage mains via plugs CAT II i e for measurements on house hold appliances for example The current measuring ranges are resistant to long term overloading up to 10 A Generous protection of all the current ranges by means of semiconductor circuit break ers prevents the fuse blowing unintentionally in many cases Sw...

Страница 2: ...ges may arise due to superimposition of components The authorised measuring range is not to be exceeded If measurements are made when the magnitude of the variable is unknown al ways select a large measuring range before shifting down to lower ones Make very sure that the voltage value be tween the measured contact and earth or be tween the ground socket and the measure ment socket does not exceed...

Страница 3: ...termined by forming various quotients involving simultaneous meas urements of current and voltage R U I below 1 mΩ above 10 MΩ S I U below 1 µS above 30 S Z U I below 1 mΩ above 10 MΩ 40 Hz 40 kHz Y I U below 1 µS above 30 S 40 Hz 40 kHz Overload protection Voltage ranges 600 V long term in all voltage ranges Current ranges 10 A of long term load ing in 3 A and 10 A ranges Electrical safety Safety...

Страница 4: ...tre zero point 5 Rotary switch to select the mea surement range 6 Ground socket 7 Current measurement socket for up to 3 A 8 Current measurement socket for up to 10 A 9 Voltage measurement socket 10 Toggle switch 2 AC DC voltage measurements 11 Power switch 4 2 Rear 12 Cover plate for battery and fuses 13 Rating plate 14 Fuse diagram 15 Lower edge 16 Feet ...

Страница 5: ...itch to If the battery is sufficiently charged the needle will point to the following range indication If this is not the case the battery will need to be replaced immediately 7 3 Zero point calibration Turn on the demo multimeter Turn the rotary switch to 600 V Connect the common ground socket and the voltage measurement socket together by means of a short connecting lead Turn the zero point trim...

Страница 6: ...n set the toggle switch 1 to Select the required current measuring range to a range measured in mA or A 8 2 AC currents up to 3 A Set the toggle switch 2 to Select the required current measuring range to a range measured in mA or A 9 Current measurements up to 10 A The demo multimeter may NOT be used for direct measurements on a building s electrical wiring installation or directly at the source o...

Страница 7: ...o Select the required measuring range to a range measured in V For measurements of voltage up to 100 mV set the rotary switch to the range 0 1 mA 100 mV 11 Measuring current and voltage together The demo multimeter may NOT be used for direct measurements on a building s electrical wiring installation or directly at the source of the mains voltage feed to the junction box See page 2 of Measurement ...

Страница 8: ...e AA IEC LR6 Place the negative pole of the battery on the spring Close the cover again afterwards 12 3 Changing fuses Before opening the casing Turn off the demo multimeter Disconnect all measuring leads Remove the cover at the rear Check the fuses Blown fuses should be replaced with ones of the same rating Close the cover again afterwards 13 Cleaning For cleaning use a soft cloth slightly mois t...

Отзывы: