360 Vision Vision i Dome Скачать руководство пользователя страница 19

Vision i Dome_VisionDome VR Installation Manual Ver 3.1

Page 19

© 360 Vision Technology Ltd.

Privacy Zone Menu (Not available on Vision i Dome)

Can be used to obscure a scene within an image e.g. private residence. Move the camera to the position 

required for the privacy zone before going into the camera OSD. You cannot manually move the camera once 

in the OSD. Use the zoom to set the size of the privacy zone. Privacy zone will cover the whole scene viewed 

when set.

• 

Define Privacy Zone - Used to set a privacy zone.

•  Seek Privacy Zone - Used to seek a privacy zone.
•  Remove Privacy Zone - Used to remove a privacy zone.

12 Important - Care of Painted Surfaces

The powder coating applied to the VisionDome external housing is recognised as being in the forefront for 

quality and finish. However, in order to preserve the aesthetic finish it is recommended that the coating is 

regularly cleaned.

Regular cleaning on a maximum three month interval, using warm and mild detergent must be undertaken. 

Abrasive cleaners including strong solvent must NOT be used at any time.

In areas where the coating may come in contact with concentrated atmospheric pollutants [marine, chemical 

and especially bird droppings] it would be prudent to clean more frequently e.g. monthly.

Full documentation of the cleaning schedule MUST be maintained to ensure that a warranty claim can be 

considered.

If damage occurs to the coating (e.g. the VisionDome is dropped, scrapped etc), repairs MUST be carried out 

immediately.

When the VisionDome is installed in areas where there is a high risk of damage from birds or their droppings, 

additional precautions and measures should be used to keep the birds away from the VisionDome e.g. fit anti-

bird spikes.

13 Storage and Handling

Visiondomes should be handled with care and must not be dropped. When Visiondomes are inside the transit 

packaging which is used for despatch from the factory, they should not be stacked to a height of more than two 

Visiondomes.

When Visiondomes are being stored before installation they should be kept in the transit packaging and located 

in a dry indoor environment preferably between 1°C and 35°C which is dry and dust free. Humidity should such 

that water vapour is non-condensing. Visiondomes can be allowed to be outside this range for short periods 

of time (24 hours maximum) for transport (e.g. in aircraft or vans) but must never be allowed to be outside the 

normal operating temperature range of -40°C to +60°C even during storage.

Before installation the Visiondome should be clean and dry. (If necessary it should be cleaned and dried taking 

care that the cover is not scratched).

14 Warranty

This information and/or any technical information – whether received verbally or writing – is given in good faith 

but without warranty and this also applies where proprietary rights of third parties are involved. The information 

provided does not release you from your obligation to check its validity and to test the products suitability for 

the intended purpose(s) and use(s). The application, use and installation of the products either in isolation or in 

conjunction with other products used, provided and installed by you on the basis of the technical advice issued 

are beyond our control and therefore remain entirely your own responsibility.

©2018 ALL DESIGNS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

Содержание Vision i Dome

Страница 1: ...Vision i Dome_VisionDome VR Installation Manual Ver 3 1 Page 1 360 Vision Technology Ltd Vision i Dome VisionDome VR Installation Configuration Manual ...

Страница 2: ...s 6 4 1 Standalone Alarmcard Setup 8 5 Basic Twisted Pair RS485 Data Wiring 12 6 Visiondome VR Protocol Address setup 12 7 VisioniDome 13 7 1 Protocol Switch S2 13 7 2 Address Switch S1 14 8 RS485 Address Settings 14 9 Vision i Dome OSD 15 9 1 PIN Number 15 10 VisionDome OSD 16 10 1 PIN Number 16 11 OSD Operation Navigation 17 12 Important Care of Painted Surfaces 19 13 Storage and Handling 19 14 ...

Страница 3: ...per installation 2 Housing Dimensional Drawing MUST NOT BE REPRODUCED OR SHOWN TO DO NOT SCALE ALL DIMENSIONS IN MM REMOVE ALL SHARP EDGES SHEET D C B A 4 3 2 1 4 3 2 1 A3 DESCRIPTION SCALE PERMISSION OF THE AUTHOR ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN C COPYRIGHT PROTECTED AND THIS DRAWING AND ALL COPIES ARE PART NUMBER 0 167 1 OF 2 TOLERANCES X 0 5 X X 0 1 X XX 0 05 A 3rd ANGLE PROJECTION 3...

Страница 4: ... GLAND 332 326 NAME M5725 A VANDAL INSTALL CAST WALL BRACKET ISS DATE REFERENC A 060617 FIRST ISSUE 060617 DATE K CRAIK RELEASED APPROVED ENGINEER MATERIAL FINISH SCALE 0 3 SCALE 0 3 External Wall Weight 5 5kg MUST NOT BE REPRODUCED OR SHOWN TO DO NOT SCALE ALL DIMENSIONS IN MM REMOVE ALL SHARP EDGES D C B A 3 2 1 3 2 1 A3 DESCRIPTION PERMISSION OF THE AUTHOR ANY THIRD PARTY WITHOUT THE DIRECT WRI...

Страница 5: ...ME COVER TWIST CAMERA ONTO WALL BRACKET AND SECURE USING LOCKING SCREW CAMERA COVER 246 mm Weight 3 8kg Weight 1 4kg Weight 1 6kg Internal False Ceiling Internal Pendant Internal Pole Bracket Internal Wall Bracket Internal Corner Bracket External Corner Bracket Weight 2 2kg Please use the appropriate fixings to suit the weight of the camera housing used ...

Страница 6: ...ion Manual Ver 3 1 Page 6 360 Vision Technology Ltd 4 Connections MAINS input 230Vac L E N MAINS FUSE VRVD PSU MAINS FUSE 1 0AF OUTPUT FUSE VRVD PSU FUSE 1 2 5AT FUSE 2 200mAT VRVD PSU 180 x 180 x 100mm Enclosure Dimensions VRVD PSU_301117 ...

Страница 7: ...ual Ver 3 1 Page 7 360 Vision Technology Ltd MAINS input 230Vac L E N MAINS FUSE VRVD XALARM PSU MAINS FUSE 1 0AF OUTPUT FUSE VRVD XALARM PSU FUSE 1 2 5AT FUSE 2 200mAT VRVD XALARM PSU 180 x 180 x 100mm Enclosure Dimensions VRVD XALARM PSU_301117 ...

Страница 8: ...s highest priority The Visiondome will seek the preset that corresponds with the new alarm When the contacts become inactive the Visiondome will seek the preset that corresponds with the previous highest priority alarm that is still active When all alarms inputs are inactive the alarm timer starts After the timer expires the Alarm PCB sends a command to the Visiondome to end the alarm mode and the...

Страница 9: ...24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 ...

Страница 10: ... 50 metres 125 metres 1 50mm 60 metres 150 metres 2 00mm 100 metres 250 metres To ensure optimum Visiondome performance these parameters must be adhered to Failure to do so will invalidate the warranty 1 2 3 4 5 6 7 8 CON4 Protocol Settings 3 4 5 6 360 Vision Off Off Off Off Pelco D 9600 baud On Off Off Off Pelco D 4800 baud Off On Off Off Pelco D 2400 baud On On Off Off Pelco P 9600 baud Off Off ...

Страница 11: ... using screw terminal CON5 A Twisted Pair Video balun is required to suit cable length to receive video signal Active Balun Twisted Pair Video Board RJ45 Connector version Power Connections if Required Connect 24Vac to CON4 LK1 LK2 can be used to switch power into the camera from the RJ45 CON3 to the two way screw connector CON4 Power Video Data Connections Connect cable to RJ45 CON3 Twisted Pair ...

Страница 12: ...n Screen Display is shown on the image from the camera for approx 20 seconds PRO 360VTL CAM 0001 S Visiondome VR Software Version PRO Protocol being used for telemetry e g 360 Vision Technology Ltd CAM Camera RS485 ID e g Cam 1 S or L Short or Long cable run Use the utility to set whether the coax used to send video is under or over 300m Second Line Shows the Visiondome VR Software Version loaded ...

Страница 13: ...xitron Extended Off On Off Off Pelco D 2400 baud or Coaxitron Extended On On Off Off Pelco P 9600 baud or Coaxitron Extended Off Off On Off Pelco P 4800 baud or Coaxitron Extended On Off On Off Pelco P 2400 baud or Coaxitron Extended Off On On Off BBV Dennard FSK Coax Off Off Off On Mark Mercer FSK Coax On Off Off On Ultrak RS485 On On Off On VCL Coax or RS485 On On On Off Forward Vision Off Off O...

Страница 14: ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 1 2 3...

Страница 15: ...General 2 SERVICING Power Reset Dome Factory Reset Dome Dome Software Version Return Exit Define Tour Define Mimic Define Preset Define Home Function Return Define Tour Define Mimic Define Preset Define Home Function Settings Menu Servicing Return SEEK PRESET Preset Number 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit START TOUR Tour Number 001 Start Tour Return Exit START MIMIC Mimic N...

Страница 16: ...ry Return Exit START TOUR Tour Number 001 Start Tour Return Exit START MIMIC Mimic Number 001 Start Mimic Return Exit DOME SETTINGS MENU Pin Number 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit DOME MENU Seek Preset Start Tour Start Mimic Settings Menu Exit TEXT FIELD EDIT 0123456789 ABCDEFG HIJKLMNOPQRSTUVWXYZ X Position 000 Y Position 000 TEXT Display OFF Accept Entry Clear Entry Retu...

Страница 17: ...elled above PREDELSPD PRE is preset position DEL is delay in seconds and SPD is speed at second This is how the camera will be programmed to move to a preset for a period of time at a set speed All nine figures must be added into the item Figures must be added in three i e preset 21 will be added as 021 Example of an item point 021005100 Move to preset 21 for 5 seconds at 100 sec Highlight ACCEPT ...

Страница 18: ...g preset 6 AF AI When PTZ Auto focus iris will activate when PTZ is used can be switched off Default is on Night Not available on Vision i Dome Col Mono Change Col Mono level settings can be changed to suit the site requirements Options are dark medium and light Default is dark This sets when the camera goes into mono mode Mono On Range is 7 to 25 A lower value will set the level on when the scene...

Страница 19: ...their droppings additional precautions and measures should be used to keep the birds away from the VisionDome e g fit anti bird spikes 13 Storage and Handling Visiondomes should be handled with care and must not be dropped When Visiondomes are inside the transit packaging which is used for despatch from the factory they should not be stacked to a height of more than two Visiondomes When Visiondome...

Страница 20: ...Vision i Dome_VisionDome VR Installation Manual Ver 3 1 Page 20 360 Vision Technology Ltd ...

Отзывы: