360 Vision Vision i Dome Скачать руководство пользователя страница 18

Vision i Dome_VisionDome VR Installation Manual Ver 3.1

Page 18

© 360 Vision Technology Ltd.

General 1

•  Digital Zoom - Use this option to enable or disable digital zoom.

•  White Balance - Change the camera white balance settings to suit the area.

•  Line Lock - (Not available on Vision i Dome) Used to line lock the camera.

•  Line Phase - (Not available on Vision i Dome) Can be used to manually adjust the line phase.

•  Video Gain - (Not available on Vision i Dome) Used to adjust the video level to suit different lengths of 

coax cable.

•  Video Lift - (Not available on Vision i Dome) Used to adjust the frequency of the video level to suit 

different lengths of coax cable.

•  Wide Dynamic - (Not available on Vision i Dome) Enable WDR. Options available are ON, Auto and 

Off. Default is off.

General 2

•  Auto Flip - Use this option to set how the camera behaves when full tilt down is reached. 

Semi - Requires a second tilt down command, when at full tilt down to spin camera 180°.

Full - Automatically spins the camera 180°

•  Proportional - Automatically reduces/increases pan/tilt speed depending on zoom ratio.

•  Freeze Presets - (Not available on Vision i Dome) This option freezes the image, when moving 

between presets.

•  Zoom Speed - Use to set preferred zoom speed, 5 is slow and 8 is fast.

•  OSD Preset Six - Go into OSD using preset 95 and you can switch off OSD access using preset 6.

•  AF AI When PTZ - Auto focus/iris will activate when PTZ is used, can be switched off. Default is on.

Night (Not available on Vision i Dome)

•  Col/Mono Change - Col/Mono level settings can be changed to suit the site requirements. Options 

are dark, medium and light. Default is dark. This sets when the camera goes into ‘mono mode’. 

•  Mono On - Range is 7 to 25. A lower value will set the level on when the scene is brighter, a higher 

value will set the level on when the scene is darker.

•  Mono Off - Range is 1 to 20. A lower value will set the level off when the scene is brighter, a higher 

value will set the level off when the scene is darker.

•  Bright Control - Options are automatic or normal. 

•  Noise Reduction - Used to reduce noise with scenes of low illumination. NR must be set to suit the 

environment. Default is off.

•  Aperture - Can be used to increase the picture detail. Default is 3.

Shutter

•  Fast Shutter - Option to enable fast shutter and set speed of the shutter.

• 

Slow Shutter - Option to alter the slow shutter speed. Altering this figure will have an effect on the low 

light capabilities of the camera.

Text Field Menu (Not available on Vision i Dome)

Navigate along alpha-numeric characters and use zoom in to select. Choose text position by inputting x and y 

co-ordinates. Set text display to on, if required.

Servicing

•  Power Reset - This will reboot the camera, no settings will be lost.

•  Factory Reset - This will reboot the camera and all the settings will be lost.

•  Dome Software Version - This shows the software version of the camera.

Содержание Vision i Dome

Страница 1: ...Vision i Dome_VisionDome VR Installation Manual Ver 3 1 Page 1 360 Vision Technology Ltd Vision i Dome VisionDome VR Installation Configuration Manual ...

Страница 2: ...s 6 4 1 Standalone Alarmcard Setup 8 5 Basic Twisted Pair RS485 Data Wiring 12 6 Visiondome VR Protocol Address setup 12 7 VisioniDome 13 7 1 Protocol Switch S2 13 7 2 Address Switch S1 14 8 RS485 Address Settings 14 9 Vision i Dome OSD 15 9 1 PIN Number 15 10 VisionDome OSD 16 10 1 PIN Number 16 11 OSD Operation Navigation 17 12 Important Care of Painted Surfaces 19 13 Storage and Handling 19 14 ...

Страница 3: ...per installation 2 Housing Dimensional Drawing MUST NOT BE REPRODUCED OR SHOWN TO DO NOT SCALE ALL DIMENSIONS IN MM REMOVE ALL SHARP EDGES SHEET D C B A 4 3 2 1 4 3 2 1 A3 DESCRIPTION SCALE PERMISSION OF THE AUTHOR ANY THIRD PARTY WITHOUT THE DIRECT WRITTEN C COPYRIGHT PROTECTED AND THIS DRAWING AND ALL COPIES ARE PART NUMBER 0 167 1 OF 2 TOLERANCES X 0 5 X X 0 1 X XX 0 05 A 3rd ANGLE PROJECTION 3...

Страница 4: ... GLAND 332 326 NAME M5725 A VANDAL INSTALL CAST WALL BRACKET ISS DATE REFERENC A 060617 FIRST ISSUE 060617 DATE K CRAIK RELEASED APPROVED ENGINEER MATERIAL FINISH SCALE 0 3 SCALE 0 3 External Wall Weight 5 5kg MUST NOT BE REPRODUCED OR SHOWN TO DO NOT SCALE ALL DIMENSIONS IN MM REMOVE ALL SHARP EDGES D C B A 3 2 1 3 2 1 A3 DESCRIPTION PERMISSION OF THE AUTHOR ANY THIRD PARTY WITHOUT THE DIRECT WRI...

Страница 5: ...ME COVER TWIST CAMERA ONTO WALL BRACKET AND SECURE USING LOCKING SCREW CAMERA COVER 246 mm Weight 3 8kg Weight 1 4kg Weight 1 6kg Internal False Ceiling Internal Pendant Internal Pole Bracket Internal Wall Bracket Internal Corner Bracket External Corner Bracket Weight 2 2kg Please use the appropriate fixings to suit the weight of the camera housing used ...

Страница 6: ...ion Manual Ver 3 1 Page 6 360 Vision Technology Ltd 4 Connections MAINS input 230Vac L E N MAINS FUSE VRVD PSU MAINS FUSE 1 0AF OUTPUT FUSE VRVD PSU FUSE 1 2 5AT FUSE 2 200mAT VRVD PSU 180 x 180 x 100mm Enclosure Dimensions VRVD PSU_301117 ...

Страница 7: ...ual Ver 3 1 Page 7 360 Vision Technology Ltd MAINS input 230Vac L E N MAINS FUSE VRVD XALARM PSU MAINS FUSE 1 0AF OUTPUT FUSE VRVD XALARM PSU FUSE 1 2 5AT FUSE 2 200mAT VRVD XALARM PSU 180 x 180 x 100mm Enclosure Dimensions VRVD XALARM PSU_301117 ...

Страница 8: ...s highest priority The Visiondome will seek the preset that corresponds with the new alarm When the contacts become inactive the Visiondome will seek the preset that corresponds with the previous highest priority alarm that is still active When all alarms inputs are inactive the alarm timer starts After the timer expires the Alarm PCB sends a command to the Visiondome to end the alarm mode and the...

Страница 9: ...24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 ...

Страница 10: ... 50 metres 125 metres 1 50mm 60 metres 150 metres 2 00mm 100 metres 250 metres To ensure optimum Visiondome performance these parameters must be adhered to Failure to do so will invalidate the warranty 1 2 3 4 5 6 7 8 CON4 Protocol Settings 3 4 5 6 360 Vision Off Off Off Off Pelco D 9600 baud On Off Off Off Pelco D 4800 baud Off On Off Off Pelco D 2400 baud On On Off Off Pelco P 9600 baud Off Off ...

Страница 11: ... using screw terminal CON5 A Twisted Pair Video balun is required to suit cable length to receive video signal Active Balun Twisted Pair Video Board RJ45 Connector version Power Connections if Required Connect 24Vac to CON4 LK1 LK2 can be used to switch power into the camera from the RJ45 CON3 to the two way screw connector CON4 Power Video Data Connections Connect cable to RJ45 CON3 Twisted Pair ...

Страница 12: ...n Screen Display is shown on the image from the camera for approx 20 seconds PRO 360VTL CAM 0001 S Visiondome VR Software Version PRO Protocol being used for telemetry e g 360 Vision Technology Ltd CAM Camera RS485 ID e g Cam 1 S or L Short or Long cable run Use the utility to set whether the coax used to send video is under or over 300m Second Line Shows the Visiondome VR Software Version loaded ...

Страница 13: ...xitron Extended Off On Off Off Pelco D 2400 baud or Coaxitron Extended On On Off Off Pelco P 9600 baud or Coaxitron Extended Off Off On Off Pelco P 4800 baud or Coaxitron Extended On Off On Off Pelco P 2400 baud or Coaxitron Extended Off On On Off BBV Dennard FSK Coax Off Off Off On Mark Mercer FSK Coax On Off Off On Ultrak RS485 On On Off On VCL Coax or RS485 On On On Off Forward Vision Off Off O...

Страница 14: ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 1 2 3...

Страница 15: ...General 2 SERVICING Power Reset Dome Factory Reset Dome Dome Software Version Return Exit Define Tour Define Mimic Define Preset Define Home Function Return Define Tour Define Mimic Define Preset Define Home Function Settings Menu Servicing Return SEEK PRESET Preset Number 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit START TOUR Tour Number 001 Start Tour Return Exit START MIMIC Mimic N...

Страница 16: ...ry Return Exit START TOUR Tour Number 001 Start Tour Return Exit START MIMIC Mimic Number 001 Start Mimic Return Exit DOME SETTINGS MENU Pin Number 0 1 2 3 4 5 6 7 8 9 Accept Entry Clear Entry Return Exit DOME MENU Seek Preset Start Tour Start Mimic Settings Menu Exit TEXT FIELD EDIT 0123456789 ABCDEFG HIJKLMNOPQRSTUVWXYZ X Position 000 Y Position 000 TEXT Display OFF Accept Entry Clear Entry Retu...

Страница 17: ...elled above PREDELSPD PRE is preset position DEL is delay in seconds and SPD is speed at second This is how the camera will be programmed to move to a preset for a period of time at a set speed All nine figures must be added into the item Figures must be added in three i e preset 21 will be added as 021 Example of an item point 021005100 Move to preset 21 for 5 seconds at 100 sec Highlight ACCEPT ...

Страница 18: ...g preset 6 AF AI When PTZ Auto focus iris will activate when PTZ is used can be switched off Default is on Night Not available on Vision i Dome Col Mono Change Col Mono level settings can be changed to suit the site requirements Options are dark medium and light Default is dark This sets when the camera goes into mono mode Mono On Range is 7 to 25 A lower value will set the level on when the scene...

Страница 19: ...their droppings additional precautions and measures should be used to keep the birds away from the VisionDome e g fit anti bird spikes 13 Storage and Handling Visiondomes should be handled with care and must not be dropped When Visiondomes are inside the transit packaging which is used for despatch from the factory they should not be stacked to a height of more than two Visiondomes When Visiondome...

Страница 20: ...Vision i Dome_VisionDome VR Installation Manual Ver 3 1 Page 20 360 Vision Technology Ltd ...

Отзывы: