50
TSS-2470 Time Delay
Replacing a Hard Drive
Each hard drive bay is numbered 0 through 3, as are the drives. If
for any reason one or more drives have been removed, they must be
reinstalled in a bay whose number matches the drive. Installation in
the wrong location will damage data stored on all drives.
Although the drives are hot swappable and can be replaced while the
system is running, it is recommended that if possible the unit be
taken offline and powered off prior to conducting any maintenance or
repairs.
1.
Turn system power OFF with the front panel button. After it has
shut down, turn off the AC power switch and unplug the AC power
cords.
2.
Remove the front panel as described on page 45.
3.
Release the lever on the front of the drive and pull the drive
out of the chassis.
4.
Replace the drive and fasten the holding plate in place.
5.
Replace the front panel.
6.
Replace the AC power cords and turn on the rear panel AC switch.
7.
Turn the system ON using the front panel button and check the
RAID array status.
8.
Check for correct operation of the TSS-2470 Time Delay.
NOTE: All drives in the RAID array must be “RAID Enabled” or “RAID
Edition” drives. Any replacement must have an actual capacity equal
to or larger than the drives that existed when the array was
originally created.
Drives that are advertised as being a particular size vary in actual
size. Before attempting to rebuild an array, check that the size of
the drive reported when it is installed is at least equal to or larger
than the existing drives in the array. The size is reported in the
bootup screen for the RAID system during power up.