10
11
2VV.
Creating innovative solutions for you and your business since 1995.
ver.8 07-12-19
6. INSTALLATION
6.4- 3 Electroinstallation
and electrical fittings
DO NOT MISS!
•
Cable should not be laid together with power cables and it should be positioned a sufficient distance from them.
•
Pay attention to the connector which should snap in when connected correctly.
•
When fixing the cable on the wall and similar, the insulation must not be disturbed.
•
In case that you will not connect data cables immediately after fixing remote control and ventilation unit, seal connectors or end of the
cables with insulation tape to ensure their protection from possible mechanical damage or short-circuiting.
•
Cable connector must not be in contact with water or any liquid.
1
4
5
6
2
3
PTPM
RJ12
Separate the box
from the control
panel (you do not
need to use any
tool)
Connect the connector to the control panel
Place the control panel into the box
Connect the cable to the box of the regulation
Pull the communica-
tion cable through
the control panel box
Attach the box
to the electrical
wiring box in the
wall
POSTHEATERR
LO
L
FLAP
N
N L
PE
CONTROL
PANEL
BOOST
PIR
RH
15V DC
+ GND
CO₂ -3
CO₂ -2
CO₂ -1
EXTERNALL
CONTROL
1
BOOST
FAN
LEVEL 1
FAN
LEVEL 2
FAN
LEVEL 3
RETURN
FAN OFFSET
FREE
COOLING
FILTER
PERIOD
ANTIFREEZE
SETPOINT
2
3
4
5
6
7
8