2N® LiftIP 2.0 User Manual
111
/
119
CPC Antenna
Call type
Command
Call type
Data
ID
Alarm
04
27
-
Lift ID
Alarm 2
04
27
-
Lift ID
Checking Call
04
26
-
Lift ID
Rescue process ended
04
84
-
Lift ID
Button Error
04
90
-
Lift ID
Button Fixed
04
90
-
Lift ID
Audio Error
04
91
-
Lift ID
Audio Fixed
04
91
-
Lift ID
The data message consists of:
Command – Call type – DATA – ID
CPC Antenna 2N Ext
Call type
Command
Call type
Data
ID
Alarm
04
27
00000
Lift ID
Alarm 2
04
27
00000
Lift ID
Checking Call
04
26
00000
Lift ID
Rescue process ended
04
84
00000
Lift ID
Button Error
04
90
00000
Lift ID
Button Fixed
04
90
00001
Lift ID
Audio Error
04
91
00000
Lift ID
•
Example
This is only a part of the data message. It does not contain the beginning, checksum
and end.
0492687654321 – Checking call, identification number 87654321.