Installation Manual 2N® IP Style
66
/
88
•
•
Installation:
Install
2N
®
Security Relay
onto a two-wire cable between the intercom and the electric lock
inside the area to be secured (typically behind the door). The device is powered and controlled
via this two-wire cable and can thus be added to an existing installation. Thanks to its compact
dimensions, the device can be installed into a standard mounting box.
Connection:
Connect
2N
®
Security Relay
to the intercom as follows:
To the active output (OUT1)
Connect the electric lock to
2N
®
Security Relay
output as follows:
To the switched output
To the passive output in series with the external power supply
The device also supports a Departure button connected between the
‘PB’
and
‘-
HeliosIP / IP
Intercom terminals. Press the Departure button to activate the output for 5 seconds.
Status Signaling:
Green LED
Red LED
Status
flashing
off
Operational mode
on
off
Activated output
flashing
flashing
Programming mode – waiting for
initialization
on
flashing
Error – wrong code received
Configuration:
Connect
2N
®
Security Relay
to the properly set Security intercom output. Refer to the
Configuration Manual for 2N IP Intercoms
for details. Make sure that one LED at least is on or
flashing.
Press and hold the
2N
®
Security Relay
Reset button for 5 seconds to put the device in the
programming mode (both the red and green LEDs are flashing).
Содержание IP Style 9157101
Страница 1: ...Installation Manual 2N IP Style v 1 1 www 2n com...
Страница 32: ...Installation Manual 2N IP Style 32 88 2N IP Style Main Unit Installation...
Страница 37: ...Installation Manual 2N IP Style 37 88 2 2 2 Mounting Box Installation Mounting Box Installation...
Страница 79: ...Installation Manual 2N IP Style 79 88 3 5 Downloads Software 2N USB driver 2N IP Eye 2N Network Scanner...
Страница 88: ...Installation manual 2N IP Style 88 88...