2N TELEKOMUNIKACE a.s., www.2n.cz
102/104
Alarm (Dispatching Office Call) Caused by Over 2-Min Long Door Opening
Specification
Call the dispatching office in case the door remains open for more than 2 minutes. It is
supposed that the door opening signalling contact is connected to Input1.
Block diagram
Whenever the door opens, the rising edge on Input1 signal (1: Event.InputChanged)
calls the defined telephone number (4: Action.BeginCall) with a 120 s delay (2: Event.
Delay).The call is only executed if the door remains open for more than 120 s (3:
Condition.InputState).
Intercom settings
1: Event.InputChanged: Input=input1; Edge=rising
2: Event.Delay: Delay=120 s; StartEvent=1
3: Condition.InputState: Input=input1; Level=1
4: Action.BeginCall: Number=1111; Event=2; Condition=3
Содержание IP series
Страница 1: ...www 2n cz Automation manual for 2N IP intercoms Configuration Manual Version 2 22 ...
Страница 18: ...2N TELEKOMUNIKACE a s www 2n cz 18 104 Example Event generated upon detection of DTMF code ...
Страница 21: ...2N TELEKOMUNIKACE a s www 2n cz 21 104 Example Event generated by entering code 12345 on a keypad ...
Страница 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 104 ...
Страница 30: ...2N TELEKOMUNIKACE a s www 2n cz 30 104 ...
Страница 33: ...2N TELEKOMUNIKACE a s www 2n cz 33 104 ...
Страница 37: ...2N TELEKOMUNIKACE a s www 2n cz 37 104 Example Event generated by receiving of a mass opendoor command ...
Страница 43: ...2N TELEKOMUNIKACE a s www 2n cz 43 104 ...
Страница 51: ...2N TELEKOMUNIKACE a s www 2n cz 51 104 ...
Страница 54: ...2N TELEKOMUNIKACE a s www 2n cz 54 104 ...
Страница 57: ...2N TELEKOMUNIKACE a s www 2n cz 57 104 ...
Страница 60: ...2N TELEKOMUNIKACE a s www 2n cz 60 104 ...
Страница 86: ...2N TELEKOMUNIKACE a s www 2n cz 86 104 6 Utilities defines the following types of events Automation ...
Страница 94: ...2N TELEKOMUNIKACE a s www 2n cz 94 104 tamper switch if installed tamper ...