background image

Installation manual 2N® IP Force

 

26

 /  

118



2N Part No.  

9137410E

Axis Part No. 01397-001

External IP Relay – 1 output

Standalone IP device which can be controlled 
by

 

HTTP

 commands sent by 

2N IP

 intercom, which can thus 

control devices on unlimited distance.

2N Part No.  

9137411E

Axis Part No. 01398-001

External IP Relay – 4 outputs, PoE

Standalone IP device which can be controlled 

by 

HTTP

 

commands sent by 

2N IP 

intercom, which can thus 

control devices on unlimited distance.

2N Part No. 

9134165E

Axis Part No. 01395-001

RFID card, type EM4100, 125 kHz

Содержание IP Force 9151101CHKW

Страница 1: ...Installation manual 2N IP Force v 2 18 www 2n com ...

Страница 2: ...t 2 2 Mechanical Installation 2 3 Electric Installation 2 3 1 Overvoltage Protection 2 4 Extending Module Connection 2 5 Button Tags 3 Function and Use 3 1 Configuration 3 2 Control 3 3 Maintenance 3 4 Downloads 4 Technical Parameters 4 1 General drawings 5 Supplementary Information 5 1 Troubleshooting 5 2 Directives Laws and Regulations 5 3 General Instructions and Cautions ...

Страница 3: ...ng AEC system the product provides mutual audibility even of persons talking at the same time under normal conditions 2N IP Force can be equipped with a colour wide angle camera which displays the calling person on the called party s video telephone or PC monitor 2N IP Force can be provided with 1 2 or 4 pre programmed buttons You can set up to three telephone numbers and time profiles for each of...

Страница 4: ...ancelling Integrated colour camera with wide angle lens Optional dial buttons including name tags and backlight Optional numerical keypad with backlight Integrated electronic lock switches with wide setting options Optional integrated RFID card reader module LAN PoE or external 12 V power supply Configuration via web interface or dedicated PC application SIP 2 0 support Up to 1999 telephone direct...

Страница 5: ...Installation manual 2N IP Force 5 118 Basic Units One Button 2N Part No 9151101W Axis Part No 01336 001 1 button control of two electric locks additional switch connection option 10 W loudspeaker IP69K ...

Страница 6: ... camera 10 W loudspeaker IP69K extra robust version control of two electric locks additional switch connection option 2N Part No 9151101CHW Axis Part No 01337 001 IP69K 1 button HD camera control of two electric locks additional switch connection option 10 W loudspeaker night vision ...

Страница 7: ...ms possibility of connecting card reader control of two electric locks additional switch connection option 10 W loudspeaker IP69K 2N Part No 9151101CRP W 1 button pictograms with camera possibility of connecting card reader control of two electric locks additional switch connection option 10 W loudspeaker IP69K ...

Страница 8: ...tograms with HD camera possibility of connecting card reader control of two electric locks additional switch connection option 10 W loudspeaker IP69K night vision 2N Part No 9151101KW Axis Part No 01338 001 10 W loudspeaker IP69K 1 button keypad control of two electric locks additional switch connection option ...

Страница 9: ...udspeaker IP69K 1 button keypad camera control of two electric locks additional switch connection option 2N Part No 9151101CHK W Axis Part No 01339 001 10 W loudspeaker IP69K 1 button keypad HD camera control of two electric locks additional switch connection option night vision ...

Страница 10: ...camera possibility of connecting card reader control of two electric locks additional switch connection option 10 W loudspeaker IP69K night vision 2N Part No 9151102CRW 2 buttons camera possibility of connecting card reader control of two electric locks additional switch connection option 10 W loudspeaker IP69K ...

Страница 11: ...1 2 buttons card reader connection option control of two electric locks additional switch connection option 10 W loudspeaker IP69K 2N Part No 9151102 X1 10W loudspeaker IP69K 2 buttons with INFO and SOS labels anti vandal buttons made of stainless steel Note customization available per request ...

Страница 12: ...151104W Axis Part No 01342 001 10 W loudspeaker IP69K 4 buttons control of two electric locks additional switch connection option 2N Part No 9151104CW 10 W loudspeaker IP69K 4 buttons camera control of two electric locks possibility of connecting additional switch ...

Страница 13: ... option night vision 2N IP Force is designed for outdoor applications and requires no additional roof W including Part Nos are intended for WAP pressure cleaning and extremely noisy environments such as highways etc 2N IP Force units can be flush or wall mounted without requiring any additional accessories Use the appropriate mounting box see below for plasterboard and hollow brick flush mounting ...

Страница 14: ...Installation manual 2N IP Force 14 118 Flush Mounting Box frame included with basic unit 2N Part No 9151001 Axis Part No 01348 001 Brick flush mounting box Dimension 132 x 223 x 83 mm ...

Страница 15: ...2N Part No 9151002 Axis Part No 01349 001 Plasterboard flush mounting box Dimension 237 x 129 x 70 mm Hole 237 x 118 mm Mounting Accessories 2N Part No 9151005 Axis Part No 01351 001 Gooseneck stand Height 120 cm 47 inch to the intercom top ...

Страница 16: ...stallation manual 2N IP Force 16 118 2N Part No 9151007 Axis Part No 01550 001 Gooseneck stand double Height 115 cm 45 and 203 cm 80 2N Part No 9151006 Axis Part No 01352 001 Installation adapter US only ...

Страница 17: ...ies Part Numbers 2N Part No 91378375 Axis Part No 01668 001 2N Part No 91378376 Axis Part No 01670 001 2N Indoor Touch 2 0 black WiFi version latter Part No 2N Indoor Touch 2 0 an elegant internal touch panel is suitable for all 2N IP intercoms On the panel s display not only can you find out who is at the door but you an also start conversation with the visitor open the lock or turn on the light ...

Страница 18: ...9 001 2N Part No 91378376WH Axis Part No 01671 001 2N Indoor Touch 2 0 white WiFi version latter Part No 2N Indoor Touch 2 0 an elegant internal touch panel is suitable for all 2N IP intercoms On the panel s display not only can you find out who is at the door but you can also start conversation with the visitor open the lock or turn on the light in the entrance hall ...

Страница 19: ...m GXV3240 VoIP video telephone GXV3240 is the successor to the popular GXV3140 model which allows for comfortable video calls in the IP network Touchscreen and keyboard control 2N Part No 91378358 Axis Part No 01421 001 Grandstream GXV3275 VoIP telephone GXV3275 is the successor to the popular GXV3175 model which allows for comfortable video calls in the IP network Touchscreen control ...

Страница 20: ...rt momentum electric pulse is sufficient for unlocking the door into the OPEN position After the door is passed through the lock is in the CLOSED position again 2N Part No 932091E BEFO 11211MB with mechanical blocking 12 V 230 mA DC low consumption Enables to mechanically close or open the lock Once unlocked the lock keeps open all the time Once closed the lock behaves as a standard electrical loc...

Страница 21: ...A DC The failsafe lock is closed when electricity is switched on When electricity is interrupted the lock is opened 2N Part No 932062E BEFO 321211 fail safe door signalling 12 V 170 mA The failsafe lock is closed when electricity is switched on When electricity is interrupted the lock is opened It contains a built in contact to indicate whether the door is open or closed Tip FAQ Electric locks Dif...

Страница 22: ...jetor with EU cable PoE injector with US cable For intercom power supply via an Ethernet cable where no PoE switch is available 2N Part No 91341481E Stabilised 12 V 2 A power supply needs to be used where no PoE is available 2N Part No 932928 12 V transformer For 230 V mains voltage For external power supply of the lock with 12 V AC voltage ...

Страница 23: ...itch for 2N IP Force front panel opening signalling 2N Part No 9151011 Axis Part No 01344 001 Internal RFID card reader 125 kHz for installation in 2N IP Force intercoms Allows the use of EM4xxx cards Another two switches two logical inputs and a Wiegand interface are available It is compatible with the 2N IP Force two button and pictogram models Includes a tamper switch to signal when the front p...

Страница 24: ...umber is read ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key 2N Part No 9151031S Axis Part No 01730 001 Internal secured RFID card reader 13 56 MHz NFC HCE Ready for 2N IP Force mounting Two switches two logical inputs and a Wiegand interface are available It is compatible with the 2N IP Force two button and pictogram models Includes a tamper switch to signal when the f...

Страница 25: ... 2N Security Relay A handy add on that significantly enhances door entry security as it prevents tampering with the intercom and forced opening of the lock To be installed between intercom and lock powered by the intercom 2N Part No 9159011 Axis Part No 01387 001 Wiegand Isolator The 2N IP Wiegand Isolator is designed for galvanic isolation of two devices separately power supplied and interconnect...

Страница 26: ...mands sent by 2N IP intercom which can thus control devices on unlimited distance 2N Part No 9137411E Axis Part No 01398 001 External IP Relay 4 outputs PoE Standalone IP device which can be controlled by HTTP commands sent by 2N IP intercom which can thus control devices on unlimited distance 2N Part No 9134165E Axis Part No 01395 001 RFID card type EM4100 125 kHz ...

Страница 27: ...2N Part No 9134173 Axis Part No 01384 001 Mifare Classic 1k RFID card 13 56 MHz 2N Part No 9159050 Axis Part No 01391 001 2N Induction Loop An induction loop transmits sound wirelessly from the 2N IP intercom to the earphones of people with hearing disabilities and enables them to hear and perceive sounds better ...

Страница 28: ...159014US Axis Part No 01404 001 2N 2Wire set of 2 adaptors and power source for EU US UK The 2N 2Wire converter allows you to use the existing wiring 2 wires from your original doorbell or door intercom to connect any IP device You do not have to configure anything all you need is a 2N 2Wire unit at each end of the cable and a power source connected to at least one of these units The 2N 2Wire unit...

Страница 29: ...itable for Internal RFID card reader Set for installation on a door enabling the status of door opening to be ascertained Used when the intercom is used for door protection to detect when the door is not closed or forcibly opened 2N Part No 9159030 Axis Part No 01389 001 External RFID card reader 125 kHz Secondary reader for connection to an internal reader Provides card entry control from both si...

Страница 30: ...l from both sides of the door IP68 cover also suitable for exteriors Reads Mifare cards 2N Part No 9154004 Axis part No 01479 001 Water proof metal button Suitable for Internal RFID card reader 2N Part No 9137420E Axis Part No 01399 001 External RFID card reader for connection to a PC using a USB interface Suitable for system management and the addition of EM41xx cards via the PC application 2N Ac...

Страница 31: ...d version 4 3 2N Mobile Key app required EMarine 2N Part No 9137424E Axis part No 01527 001 Ext secured RFID Reader 13 56 MHz 125 kHz NFC HCE USB interface External secured RFID card reader for connection to PC using a USB interface Suitable for system administration and adding 13 56 MHz 125 kHz cards and Android platform devices supporting NFC HCE using 2N IP intercom web interface or the 2N Acce...

Страница 32: ...05 Enhanced Audio 2N Part No 9137906 Enhanced Video 2N Part No 9137907 Enhanced Integration 2N Part No 9137908 Enhanced Security 2N Part No 9137909 Gold 2N Part No 9137910 Axis Part No 01381 001 InformaCast 2N Part No 9137915 NFC 2N Part No 9137916 Lift Module Tip ...

Страница 33: ...articular advice please contact your local distributor of 2N products Tip FAQ Induction loop How to connect it with 2N IP intercoms Safety Always abide by this information to prevent persons from injury Warning Always abide by this information to prevent damage to the device Caution Important information for system functionality Tip Useful information for quick and efficient functionality Note Rou...

Страница 34: ...d wrench Bushings enclosed 1x big two hole sealed bushing with nut 1x spare sealing for big bushing for a thick cable one hole 1x big blank with nut 1x small bushing with nut 1x bushing plug big size 2x bushing plugs small size 1x Brief Manual 1x mounting template 1x A5 transparent name plate foil 1x spare name tag 1x grounding connector with the screw 4x 5 x 90 mm screws 4x intelligent 8 x 50 mm ...

Страница 35: ... of the wall Stainless steel screws are used for the 2N IP Force assembly Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment Having removed the front panel make sure that no dirt gets inside the product especially onto the sealing surface and microphone sound guides Caution The warranty does not apply to the product defects and failure...

Страница 36: ...Force 36 118 F l u s h M o u n ti n g C l a s si c B ri c k s Warning Be sure keep strictly the hole dimensions while mounting the device into classic bricks without the flush mounting box as shown in the picture with dimensions ...

Страница 37: ...Installation manual 2N IP Force 37 118 What You Need The brick flush mounting box Part No 9151001 Hole 132 x 223 x 83 mm ...

Страница 38: ...Installation manual 2N IP Force 38 118 If y o u u s e t h e b ri c k fl u s h m o u n ti n g b o x f ol lo w t h e ...

Страница 39: ... the rest under the intercom bottom Insert the supplied screws in the side mounting holes making sure that they penetrate into the flush mounting box nuts Tighten all the screws properly Tip The screw tightening sequence may affect the intercom position We recommend to seal the frame wall gap with a silicone or another sealant to avoid wall dampening as a result of water leakage Do not complete mo...

Страница 40: ...tions included therein Caution The hole depth depends on the insulation layer thickness If the insulation layer is rather thick you may need longer screws If there are hollow bricks under the insulation make sure that your screws pass through the whole dowel 50 mm and fix the dowel reliably Make sure that the dowel holes have the required diameter If the diameter is too large the dowels may get lo...

Страница 41: ...mounting box Part No 9151001 Hole 132 x 223 x 83 mm Suppose you intend to install your 2N IP Force unit into a wall made of hollow bricks Note that the external side of the bricks gets damaged by cutting and the dowels cannot practically be fixed into the thin internal part of the bricks Therefore use the brick flush mounting box and follow the instructions included therein ...

Страница 42: ...P Force 42 118 Wall Mounting What You Need Just your 2N IP Force unit Wall surface mounting is used where flush mounting is inapplicable in concrete and steel structures entry barrier columns etc The frame is not used Caution ...

Страница 43: ... the unit as a reserve Insert the plugs in the unused bushings and tighten the bushing nuts carefully Do not complete mounting until you have finished electrical installation Where cables lead along the surface use the bushings included in the delivery Stand Mounting This mounting method is suitable for entrance installations in particular What you need for installation Wall mounting may be a prob...

Страница 44: ...cording to the type of surface Use a cable bushing for the 2N IP Force cable fee out Use of Cable Bushings The cable bushings included in the 2N IP Force delivery are designed for the following cables Big bushing for two cables of the diameter of 5 6 mm UTP cable or upon insert replacement for one thick cable tube of the diameter of up to 14 mm Small bushing for one cable of the diameter of 5 8 mm...

Страница 45: ...completely 2 Remove the sealing including the cover from the bushing Cut either of the components as shown in the figures 3 Put the bushing nut on the cable and insert the sealing 4 Replace the cover onto the sealing Tip Even a LAN cable including the RJ 45 connector can go through the big bushing See below for instructions ...

Страница 46: ...l the cable connector though the bushing body into the intercom and clip it into the motherboard connector 6 Move the sealing including the cover along the cable as far as the bushing body or add a plug if necessary 7 Replace and tighten the nut ...

Страница 47: ...v3 and higher Factory Default Resetting PCB version 555v2 Grounding Mounting Completion Available Switches PCB Connectors Picture shows the lay out of connectors on the 2N IP Force printed circuit board PCB Cables accessories and other system components are connected to connectors X1 through X22 Connectors description X1 Loudspeaker X2 Button 2 X3 Button 3 X4 Camera module X5 Button 1 SW1 Reset bu...

Страница 48: ... X16 Right hand microphone X17 Relay NO and NC contact max 30 V 1 A AC DC Used for connection of non critical devices only lights e g X18 Switched output 9 up to 13 V DC depending on power supply PoE 9 V adaptor power supply voltage minus 1 V max 700 mA X19 Power input 12 V 15 2 A DC LED1 2 System status indicators LED3 LAN connection activity indicator 2N IP Force Connectors PCB Version 555v2 ...

Страница 49: ...Installation manual 2N IP Force 49 118 2N IP Force Connectors PCB Version 555v3 ...

Страница 50: ...Installation manual 2N IP Force 50 118 2N IP Force Connectors PCB Version 555v4 ...

Страница 51: ...Installation manual 2N IP Force 51 118 2N IP Force Connectors PCB Version 555v5 Tip Output wiring diagram for Relay terminals ...

Страница 52: ...ble of category Cat 5e or higher The system is equipped with the Auto MDIX function and so both the straight and crossed cable versions can be used Wiring diagram for the controlled device s electric circuit closing Wiring diagram for the controlled device s electric circuit opening Caution We recommend the use of a LAN surge protection ...

Страница 53: ...ements If your LAN in incompatible insert the PoE injector Part No 91378100E US between 2N IP Force and the nearest network element Electric Lock Connection 2N IP Force is equipped with an electrically isolated relay switch with NO and NC contacts terminal block X17 max 30 V 1 A AC DC and 9 up to 13 V DC depending on power supply PoE 9 V adaptor power supply voltage minus 1 V max 600 mA switched o...

Страница 54: ...e RESET button Wait until the red and green LEDs go on simultaneously on the device and the acoustic signal can be heard approx 15 35 s Release the RESET button The device automatically announces the current IP address Warning When you connect a device containing a coil such as a relay or an electromagnetic lock it is necessary to protect the intercom against voltage peak while switching off the i...

Страница 55: ...rd approx 15 35 s Wait until the red LED goes off and the acoustic signal can be heard approx for another 3 s Release the RESET button The following network parameters will be set after restart IP address 192 168 1 100 Network mask 255 255 255 0 Default gateway 192 168 1 1 Note The delay after pressing RESET till the first light and sound signalling is set to 15 35 s depending on the 2N IP interco...

Страница 56: ...he acoustic signal can be heard approx for another 3 s Release the RESET button Factory Reset PCB version 555v5 and higher Follow the instructions below to reset the factory default values Press and hold the RESET button Wait until the red and green LEDs go on simultaneously and the acoustic signal can be heard approx 15 35 s Wait until the red LED goes off and the acoustic signal can be heard app...

Страница 57: ...you press the button for short time device will reboot only SW1 button is available in devices with PCB version 555v3 and higher For devices with PCB version 555v2 see procedure below Caution In case of resetting the factory default settings on a device with a version of firmware 2 18 or higher it is necessary to reprogram the 2N Security Relay using the instructions from section 2 4 Note The time...

Страница 58: ...he Normal operation position Reconnect the power supply The device will be reset to factory default Normal operation Default setup Configuration jumpers X6 PCB version 555v2 Grounding We recommend to ground the intercom in order to improve the static electricity resistance For proper grounding you need a cable of the minimum cross section of 4 mm2 Connect the cable to the connector in the bottom p...

Страница 59: ...ce for the board if you are installing a four button board Tighten the four screws thoroughly with the wrench enclosed Torx 20 to make the panel fit tightly to the metal chassis Available Switches Caution Properly installed intercom is waterproof An incorrect mounting may compromise the intercom watertightness Water leakage may damage the electronic part of the system Stainless steel screws are us...

Страница 60: ...oE 9 V adaptor power supply voltage minus 1 V max 600 mA Additional Switch Part No 9151010 Relay 2 Passive relay switch NO and NC contacts up to 30 V 1 A AC DC Used for connection of non critical devices only lights e g Output 2 Active switch output 9 up to 13 V DC depending on power supply PoE 9 V adaptor power supply voltage minus 1 V max 600 mA Internal RFID Card Reader 125 kHz Part No 9151011 ...

Страница 61: ...ply voltage minus 1 V max 600 mA Only one module marked by can be used 2 3 1 Overvoltage Protection Recommendations for Additional Overvoltage Protection Installation If running a outside a building b on in an outer wall or roof the 2N device wiring may be exposed to atmospheric effects resulting in overvoltage that may subsequently damage any devices installed outside the building on its outer wa...

Страница 62: ...here the wires leave the building OVP overvoltage protection 2 4 Extending Module Connection 2N IP Force allows the following extending modules to be connected Additional Switch Internal RFID Card Reader 125 kHz Internal RFID Card Reader 13 56 MHz Internal secured RFID Card Reader 13 56 MHz Security Relay Wiegand Isolator Induction Loop external Induction Loop internal ...

Страница 63: ...h to the 2N IP Force basic unit The purpose of the tamper switch is to signal any unauthorised opening of the intercom to prevent a theft e g It is recommended to use the tamper switch Specifications version 5 IN2 terminals for input in passive active mode 30 V to 30 V DC OFF open OR UIN 1 5 V ON closed contact OR UIN 1 5 V RELAY2 terminals 30 V 1 A AC DC NO NC contact OUT2 active output 12 V 600 ...

Страница 64: ... enclosed plastic support 6 onto the switch board bottom side Put the switch board 4 in the main board connector making sure that the screw hole is directly above the spacer According to your model If you are mounting the switch into a two nameplate model fit the switch board with the enclosed 10 5 mm spacer 3 and reinstall the button PCB 1 If you are mounting the switch into a keypad model reinst...

Страница 65: ...Installation manual 2N IP Force 65 118 ...

Страница 66: ...Installation manual 2N IP Force 66 118 ...

Страница 67: ...Installation manual 2N IP Force 67 118 Module settings Refer to the Configuration Manual for details Connection ...

Страница 68: ...module is intended for mounting into the 2N IP Force model 9151102CR 9151102R 9151101CRP and 9151101RP These models have an window which is necessary for antenna operation If the Internal RFID Card Reader is installed it is not possible to install the Additional Switch Function The 2N IP Force Internal RFID Card Reader adds two logical inputs two additional switches and a tamper switch to the 2N I...

Страница 69: ...IP Force cover Relay output Switching contact 30 V 2 A AC DC Active output 12 V 700 mA transistor switched output Logical inputs Active mode requires external voltage JP2 jumper OFF UIN ON min 2 5 V UIN OFF max 1 5 V UIN max 48 V IIN UIN 48 V max 1 mA Passive mode requires external contact only JP2 jumper ON UOUT approx 8 3 V ILOOP approx 0 5 mA Signalling output Internal red LED under reader wind...

Страница 70: ...Mounting guide ...

Страница 71: ...support 6 to the reader board from the bottom side Put the reader board 4 in the main board connector making sure that the mounting hole is directly above the spacer Screw in a remaining metal spacer 3 10 5 mm long Fit the button PCB 1 back to its position using original bolts 2 If you want to use the tamper switch to detect unauthorized opening the case as a theft protection insert the tamper boa...

Страница 72: ...Installation manual 2N IP Force 72 118 ...

Страница 73: ...Module setting ...

Страница 74: ... outputs and reader Refer to the Automation manual for details of input red LED and tamper function and use Connection Wiegand Input Technical Parameters Current 5 mA Input resistance 680 Ohm Pulse length 50 μs Delay between pulses approx 2 ms Recommended Wiring Diagram for Reader with Bus Driver ...

Страница 75: ...rted This module is intended for mounting into the 2N IP Force model 9151101RPW 9151101CRPW 9151101CHRPW 9151102RW 9151102CRW and 9151102CHRW These models have an window which is necessary for antenna operation If the Internal RFID Card Reader is installed it is not possible to install the Additional Switch 9151031 9151017 Function The 2N IP Force Internal RFID Card Reader adds two logical inputs ...

Страница 76: ...ID iClass FeliCa ST SR IX 2N Mobile Key RFID Reader 9151017 is compatible with cards only card serial number is read ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key Relay output Switching contact 30 V 2 A AC DC Active output 9 to 12 V 700 mA transistor switched output Depends on power supply PoE 9 V or power supply voltage minus 1 V Logical inputs Active mode requires ex...

Страница 77: ...short metal spacers enclosed to the reader Take a longer one 5 12 mm long Screw it into the free hole Plug an enclosed plastic support 6 to the reader board from the bottom side Put the reader board 4 in the main board connector making sure that the mounting hole is directly above the spacer Screw in a remaining metal spacer 3 10 5 mm long Fit the button PCB 1 back to its position using original b...

Страница 78: ...Installation manual 2N IP Force 78 118 ...

Страница 79: ...Installation manual 2N IP Force 79 118 ...

Страница 80: ...Module setting ...

Страница 81: ... 56 MHz The Internal RFID Card Reader 13 56 MHz Part No 9151031S 9151019 is used for reading RFID card Ids in the 13 56 MHz band NFC supported This module is intended for mounting into the 2N IP Force model 9151101RPW 9151101CRPW 9151101CHRPW 9151102RW 9151102CRW a 9151102CHRW These models have an window which is necessary for antenna operation If the Internal RFID Card Reader is installed it is n...

Страница 82: ...equency 13 56 MHz Minimum reading distance 30 mm above 2N IP Force cover RFID card reader 9151031S is compatible with cards optionally card serial number or PAC ID is read ISO14443A Mifare DESFire PicoPass HID iClass FeliCa ST SR IX 2N Mobile Key HID SE Seos iClass SE Mifare SE RFID card reader 9151019 is compatible with cards optionally card serial number or PAC ID is read ISO14443A Mifare DESFir...

Страница 83: ...Active output ...

Страница 84: ...emount a button PCB 1 Don t disconnect its cable There will stay four spacers after the switch board removal Dismount the bottom right one There are two short metal spacers enclosed to the reader Take a longer one 5 12 mm long Screw it into the free hole Plug an enclosed plastic support 6 to the reader board from the bottom side Put the reader board 4 in the main board connector making sure that t...

Страница 85: ...Installation manual 2N IP Force 85 118 ...

Страница 86: ...Installation manual 2N IP Force 86 118 ...

Страница 87: ...Module setting ...

Страница 88: ...lation manual 2N IP Force 88 118 Refer to the Configuration Manual for details of Wiegand outputs and reader Refer to the Automation manual for details of input red LED and tamper function and use Connection ...

Страница 89: ...Security Relay ...

Страница 90: ...y Relay includes a relay that can only be activated if the valid opening code is received from the intercom Specifications Passive switch NO and NC contacts up to 30 V 1 A AC DC Switched output Where the security relay is fed from the intercom 9 to 13 V DC is available on the output depending on the power supply PoE 9 V adapter source voltage of minus 1 V 400 mA DC Where the security relay is fed ...

Страница 91: ...e the output for 5 seconds Status signalling Green LED Red LED Status blinking off Operational mode on off Activated output blinking blinking Programming mode waiting for initialisation on blinking Error wrong code received Configuration Connect the 2N Security Relay to the properly set intercom switch output refer to the Configuration Manual Make sure that one LED at least on the 2N Security Rela...

Страница 92: ...ith separate power supply and interconnected via the Wiegand bus The 2N Wiegand Isolator protects the interconnected devices against communication errors and or damage Caution In case of resetting the factory default settings on a device with a version of firmware 2 18 or higher it is necessary to reprogram the 2N Security Relay using the instructions above Tip FAQ 2N Security Relay what it is and...

Страница 93: ...two wire Wiegand bus in one direction and a status LED signal in the other direction The module is power supplied from the Wiegand bus receiver side Specifications 2 wire WIEGAND IN 2 wire WIEGAND OUT LED IN switched against GND on WIEGAND OUT side Open LED OUT switched against GND on WIEGAND IN side up to 24 V 50 mA 5 to 16 V 10 mA power supply from Wiegand bus receiver side 500 V DC isolation st...

Страница 94: ...Installation manual 2N IP Force 94 118 Connection ...

Страница 95: ...nd two wires for signal input the wires are connected into interconnection connector If you shorten the cable follow the colour marking Before wall mounting run the cable through the hole that you have prepared Then mark two mounting holes on the wall through the amplifier front Remove the amplifier and drill the mounting holes Use the plugs and screws included in the delivery Use a drill of the d...

Страница 96: ...ull power output 1 4 A sine wave signal 1 A pink noise signal Transition to standby w o signal 10 s Input level basic 100 mV 6 Vrms Input level increased 1 V 35 Vrms Input impedance 2 kΩ parallel with 0 3 H Output current 1 Ω load 2 2 Arms sine wave Full power output 1 6 Arms pink noise Output current 8 Ω load 730 mArms sine wave signal Half power output 520 mArms pink noise signal Output short ci...

Страница 97: ... plastic support 6 to the reader board from the bottom side Put the reader board 4 in the main board connector making sure that the mounting hole is directly above the spacer Screw in a remaining metal spacer 3 10 5 mm long Fit the button PCB 1 back to its position using original bolts 2 If you want to use the tamper switch to detect unauthorized opening the case as a theft protection insert the t...

Страница 98: ...Installation manual 2N IP Force 98 118 ...

Страница 99: ...Installation manual 2N IP Force 99 118 ...

Страница 100: ... thus are not exposed to the risk of loss of components while replacing the tags Loosen the name plate screw using the wrench enclosed for example You can open the name plate window like a door without losing the tightened screw Remove the used or blank name tag and insert a new tag Close the name plate window and tighten the screw appropriately Check the click effect of the buttons if the button ...

Страница 101: ...orce is switched into the dynamic IP address mode i e it obtains the IP address automatically if a properly set DHCP server is available in your LAN If no such DHCP server is available you can operate 2N IP Force in the static IP address mode If your device remains inaccessible you have forgotten the IP address or the LAN configuration has changed for example change the LAN settings using the butt...

Страница 102: ... supply or disconnect and reconnect it if already connected Wait for the first acoustic signal Press buttons 1 1 1 2 2 3 sequentially The acoustic signal indicates mode switching Wait until the device is restarted automatically Note Be sure to press the button sequence within thirty seconds after the sound signal for security reasons Up to 2 s intervals are allowed between the presses ...

Страница 103: ...ct it if already connected Wait for the first acoustic signal Press buttons 2 1 1 2 2 3 sequentially The acoustic signal indicates mode switching Wait until the device is restarted automatically 2N IP Force gets the IP address upon restart only if the DHCP server is configured properly Caution The 1 1 1 2 2 3 sequence must be entered within 30 seconds after the first sound signal for security reas...

Страница 104: ...s mode switching Wait until the device is restarted automatically The static IP address mode will be switched into the dynamic IP address mode and vice versa upon restart 3 2 Control This subsection describes how to control 2N IP Force when viewed by an external user Speed Dial Buttons Press the speed dial buttons on the basic unit to make quick dialling for the first 1 2 or 4 positions depending ...

Страница 105: ...l can only be used for positions 1 to 4 The remaining positions can be retrieved via the numerical keypad if the Speed dial using digits function is enabled in configuration Procedure Enter the position number using your numerical keypad 05 15 200 1759 e g two digits at least and four digits at most and press for confirmation You can also push the button anytime to terminate a call if enabled so i...

Страница 106: ...tion Activate deactivate a profile using the numerical keypad in order to define call routing to the telephone directory numbers more specifically Procedure Enter the numerical profile activating deactivating code and press for confirmation A successful entering of a valid code is signalled acoustically by for profile for activation or for profile for deactivation An invalid code is signalled acou...

Страница 107: ...void peroxide based cleaners Tip The 2N IP Force models of Part Nos 9151101W and 9151101CW may be cleaned with WAP high pressure washers Caution Always use the product for the purpose it was designed and manufactured for in compliance herewith The manufacturer reserves the right to modify the product in order to improve its qualities 2N IP Force contains no environmentally harmful components When ...

Страница 108: ... control Adjustable with automatic adaptive mode Full duplex Yes AEC Speech transmission index STI 0 80 Audio stream Protocols RTP RTSP Codecs G 711 G 729 G 722 L16 16 kHz Camera SD Sensor 1 4 colour CMOS Resolution 640 H 480 V Frame rate Up to 30 snaps s Sensor sensitivity 1 9 V lux sec 550 nm View angle 135 H 109 V Infrared light Yes Focal length 1 1 mm Focal length HD version 2 3 mm Camera HD S...

Страница 109: ...flows in the Services Phone Video menu for calls and in the Services Streaming RTSP menu for streaming The set bandwidth represents the value that the codec has to approach on a long time average The data flows can vary depending on the scene to be scanned The measued data flow values correspond to the test view of a person standing in front of the intercom H 264 Low quality QVGA 320 x 240 10 fps ...

Страница 110: ...Part No 9151016 only card serial number is read ISO IEC 14443A Mifare Classic 1k 4k DESFire EV1 Mini Plus S X Ultralight Ultralight C ISO IEC 14443B CEPAS HID iCLASS JIS X 6319 Felica Supported cards on 13 56 MHz NFC version Part No 9151017 only card serial number is read ISO IEC 14443A Mifare Classic 1k 4k DESFire EV1 Mini Plus S X Ultralight Ultralight C ISO IEC 14443B CEPAS HID iCLASS JIS X 631...

Страница 111: ...aluminium cast product front panel aluminium cast fiberglass FR4 91511xxxR Colour Not from RAL scheme matching equivalent would be 9004 glossy black Working temperature 40 C to 55 C Working relative humidity 10 95 non condensing Storing temperature 40 C to 70 C Dimensions 217 x 109 x 83 mm 242 x 136 x 83 mm incl frame Weight netto max 2 kg brutto max 2 5 kg Covering level IP65 IP69K 91511xxxW Resi...

Страница 112: ...Installation manual 2N IP Force 112 118 Flush mounting Plasterbo ard mounting Flush mounting with box ...

Страница 113: ...s equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules NOTE These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause ha...

Страница 114: ...dges that the product device can achieve the guaranteed performance and full functionality pursuant to the manufacturer s instructions only if the latest product device version is used after having been tested for full interoperability and not having been determined by the manufacturer as incompatible with certain versions of other products and only in conformity with the manufacturer s instructio...

Страница 115: ...the product incurred as a result of misplacement incompetent installation and or undue operation and use of the product in contradiction herewith The manufacturer assumes no responsibility for any malfunction damage or destruction of the product caused by incompetent replacement of parts or due to the use of reproduction parts or components The manufacturer shall not be liable and responsible for ...

Страница 116: ...red by the consumer in case the product is used and handled contrary to the said regulations and provisions The consumer shall at its own expense obtain software protection of the product The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software The consumer shall without delay change the access password f...

Страница 117: ...or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may not be taken into parts or short circuited either ...

Страница 118: ...Installation manual 2N IP Force 118 118 ...

Отзывы: