clips. When the mortar hardens, break off the clips and cap the box with the cover provided. Use
anchoring elements to fix the device into plasterboard.
For actual fixing of the
2N
®
Indoor View
to the flush-mount box, have the 2.5 mm Allen key
which is included in the box of the
2N
®
Indoor View
at the ready.
2.2 Quick Installation Guide
Remove the cover from the walled-in
2N
®
Indoor View
flush mounting box. Remove the pre-
prepared cabling, UTP cable, doorbell twin cable and power supply cable. Shorten the cables to
150 mm or less as required. Connect the doorbell twin cable or power supply cable to the
connector provided. Crimp the RJ-45 connector onto the UTP cable. Take
2N
®
Indoor View
and
lean its bottom edge against the wall below the flush mounting box. First plug the green power/
doorbell connector. Connect the LAN connector. Put the cables carefully in the pre-drilled
2N
®
Indoor View
back slot to prevent them from blocking any horizontal levelling movement
during the final installation stage. Insert
2N
®
Indoor View
in the flush mounting box making sure
that it clicks onto the levelling pins, The pins allow for a 5–6 °
inclination on either side for
Tip
•
Note
When installing the
2N
®
Indoor View
into the wall, the local standards relating to
installation of electrical devices in flammable material must be taken into
consideration.