2N® Helios IP Automation Configuration
1.2
The 2N
®
Helios IP web interface helps you configure block combinations (Automation)
easily. The configuration shown in the figure below corresponds to the example above.
2N
®
Helios IP allows up to 12 blocks to be created and interconnected (regardless of
the block type - events, actions and conditions). Multiple actions can be assigned to an
event or condition. Thus, you can create 6 actions and assign them to 6 events, or
create 11 actions and assign them to 1 event, for example.
Block Parameter Settings
Select the required Event (Event.xxx), Action (Action.xxx) or Condition
(Condition.xxx) in the
Block type
column. Set one or more parameters for the blocks
in the respective row of the
Parameters
column - refer to the block describing
subsections below for the supported parameters. Separate the parameters with a
colon if more parameters are required.
The changes will not be executed until you press the
Save
button in the right-hand
bottom corner of the page.
If you have set a parameter correctly, a green mark will appear at the end of the
respective block definition row. If not (if you enter a wrong parameter name/value or
fail to complete an obligatory block parameter), a red mark will appear at the end of
the row. Move your mouse cursor to the red mark to display the Help to find the error.
If all the required blocks have been configured correctly (there is a green mark on
every row), 2N
®
Helios IP Automation will be enabled. If there is a red mark, the 2N
®
Helios IP Automation function will be disabled.