Examples of Use
1.7
Calling to Dispatching Office in Case of Unauthorised
Door Opening with Service Code Blocking Option
Specification
Call the selected telephone number whenever the tamper switch is disconnected
(device opened). Enable blocking and re-enable numerical code alarm entered
from the intercom keypad.
Block diagram
The rising edge on the tamper input (1: Event.InputChanged) initiates calling to
the defined telephone number (5: Action.BeginCall) in case the defined condition
is met. The condition (4: Condition.FlipFlopRS) is validated by the intercom restart
or entering the selected code (2: Condition.CodeEntered) from the numerical
keypad. If another code is entered (3: Condition.CodeEntered), the condition will
be invalid.
Intercom settings
1: Event.InputChanged: Input=tamper; Edge=rising
2: Event.CodeEntered: Code=164575
3: Event.CodeEntered: Code=111
4: Condition.FlipFlopRS: SetEvent=3; ResetEvent=2; ResetValue=1
5: Action.BeginCall: Number=1111; Event=1; Condition=4
InputChanged
Input=tamper
Edge=rising
Event (1)
BeginCall
Number=1111
Event=1
Condition=4
Action (5)
CodeEntered
Code=164575
Event (2)
CodeEntered
Code=111
Event (3)
FlipFlopRS
SetEvent=3
ResetEvent=2
ResetValue=1
Condition (4)