895
Switch 2
password
memory 5
empty
896
Switch 2
password
memory 6
empty
901
Dialling type
0–1
0
0 = tone
1 = pulse 40/60
911
Count of
rings before
incoming call
pick-up
1–99
2
Define the off-hook moment during
ringing.
912
Maximum
call time
15–990 s
120 s
Use the call-extending command
(parameter 924) to extend the call.
0=disabled (DTMF 4 or *).
913
Login time
limit
10–990 s
60 s
Set the maximum period of time for
the control centre staff to answer the
call and send confirmation, otherwise
hangs up and dials the next
2N Lift1
®
number. Counted from the end of
dialling.
914
Delayed call
0–100 s
0 s
Applied only if the CANCEL input is
connected.
915
Hang-up
timeout
between
calls
5500–9999
ms
5500 ms
916
CANCEL
input
inversion
0–1
0
0 = contact closed (or voltage
present) at open door
1 = contact closed (or voltage
present) at closed door
933
Receive
volume
0–16
16
16 = maximum volume (0 dB)
0 = minimum volume (-16 dB)
934
Transmit
volume
0–16
16
935
Message
volume
0–16
16
940
Minimum
dialtone time
200–2000
ms
400 ms
The tone must be longer than the
busy tone half-period.
941
Minimum
continuous
tone time
200–9999
ms
7000 ms
If the tone is longer,
hangs
2N Lift1
®
up.
942
Minimum
busy tone
period
100–500 ms 100 ms
Use these parameters to adjust the
busy tone detection.
943
Maximum
busy tone
period
100–2500
ms
944
Maximum
busy tone -
gap
10–400 ms
50 ms