background image

11

2N  TELEKOMUNIKACE a.s., www.2n.cz

®

Mounting Accessories

9155014

Part No.

Flush mounting box, 1-module

9155015

Part No.

Flush mounting box, 2-module

Part No. 9155061

Backplate, 1 module

Part No. 9155062

Backplate, 2 modules

The mounting boxes for 

are compatible with the

2N Helios IP Verso

®

2N Access Unit

®

, refer to the table below:

Part No.

Name

Description

9155011

2N Helios

®

IP Verso

Flush
mounting
frame,
1-module

Covering frame for the 1-module brick/plasterboard flush
mounting box. This 1-module frame is used for connection
of an OUT card reader or keypad, for example. Remember to
order the frame when you order a 1-module flush mounting
box, Part No. 9155014.

Содержание 2N Access Unit 916009

Страница 1: ...www 2n cz Version 2N Access Unit Access Control Installation Manual 2 2 ...

Страница 2: ...nd to answer your questions about 2N products and services On www faq 2n cz you can find information regarding products adjustment and instructions for optimum use and procedures What to do if 2N TELEKOMUNIKACE a s hereby declares that the 2N product complies with Access Unit all basic requirements and other relevant provisions of the 1999 5 EC directive For the full wording of the Declaration of ...

Страница 3: ... 2 Popis a instalace 20 2 1 Než začnete 21 2 2 Mechanická montáž 22 2 3 Elektrická instalace 45 2 4 Připojení rozšiřujících modulů 51 2 5 Dokončení montáže 59 3 Údržba 61 4 Technické parametry 62 5 Doplňkové informace 64 5 1 Řešení problémů 65 5 2 Směrnice zákony a nařízení 66 5 3 Obecné pokyny a upozornění 68 ...

Страница 4: ...pad module that allows you to use the intercom for code lock switch activation or phone number user number calling Integrated card reader moduleprovides the RFID card access control functionality With additional software settings you can control more functions than the door lock using the card Electric lock switch This switch can be can be controlled via a numeric keypad PC application or any phon...

Страница 5: ...ng options brick plasterboard flush mounting wall mounting Optional numeric keypad with backlight Use of multiple modules of the same type e g building entrance exit card reader Integrated electronic lock switches with wide setting options Integrated RFID card reader module LAN PoE or external 12V power supply Configuration via web interface or special PC application HTTP server for configuration ...

Страница 6: ...související produkty Basic Units Part No 916009 2N Access Unit 125kHz Part No 916010 2N Access Unit 13 56MHz NFC Tip Supported auxiliary modules 2N Helios IP Verso modules are supported RFID card reader 125kHz 13 56MHz keypad 5 button module Wiegand etc ...

Страница 7: ...le frame is used for connection of an OUT card reader or keypad for example Remember to order the frame when you order a 1 module flush mounting box Part No 9155014 9155012 Part No Flush mounting frame 2 module Covering frame for the 2 module brick plasterboard flush mounting box Remember to order the frame when you order a 2 module flush mounting box Part No 9155015 ...

Страница 8: ... wall surface mounting 5 3 Extending Modules Tip The 1 module frame is used when an auxiliary module from 2N Helios is mounted onto an extended interconnecting cable for an OUT IP Verso card reader or keypad for example Tip Remember to order the flush mounting frame when you order a brick plasterboard flush mounting box 1 module frame Part No 1 module flush mounting box 9155011 Part No 9155014 2 m...

Страница 9: ...SFire EV1 Mini Plus S X Ultralight Ultralight C ISO 14443BCEPAS HID iCLASS JIS X 6319Felica Part No 9155040 2N Helios IP Verso 13 56MHz RFID Card Reader NFC Preparation The card reader module works with as an 2N Access Unit OUT card reader The module supports cards key fobs and or other 13 56MHz standard carriers ISO 14443AMifare Classic 1k 4k DESFire EV1 Mini Plus S X Ultralight Ultralight C ISO ...

Страница 10: ... other systems access security via the Wiegand interface The module is installed under another module i e cannot be installed directly into the2N Access must be mounted Unit outside Part No 9155034 2N Helios IP Verso I O Module The logic input output module helps you integrate various sensors and control doors or other equipment The module is installed under another module i e cannot be installed ...

Страница 11: ...ting boxes for are compatible with the 2N Helios IP Verso 2N Access Unit refer to the table below Part No Name Description 9155011 2N Helios IP Verso Flush mounting frame 1 module Covering frame for the 1 module brick plasterboard flush mounting box This 1 module frame is used for connection of an OUT card reader or keypad for example Remember to order the frame when you order a 1 module flush mou...

Страница 12: ...ction of an OUT card reader or keypad for example 9155022 2N Helios IP Verso Wall mounting frame 2 module Covering frame for wall surface mounting 9155061 2N Helios IP Verso Backplate 1 module A backplate for glass or uneven surface mounting For 1 module 9155062 2N Helios IP Verso Backplate 2 module A backplate for glass or uneven surface mounting For 2 modules 9155030 2N Helios IP Verso Infopanel...

Страница 13: ...P Verso Wiegand module The Wiegand module helps you interconnect your system with other systems access security via the Wiegand interface The module is installed under another module i e cannot be installed directly into the must 2N Access Unit be mounted outside 9155040 2N Helios IP Verso RFID card reader preparation for NFC The card reader module works with the as 2N Access Unit an OUT card read...

Страница 14: ...A very short electric pulse is enough to put the lock into the OPEN position and unlock the door After passage the lock gets in the CLOSED relax position again 932091E Part No BEFO 11211MB with mechanical blocking 12V 230mA DC low consumption You can set the lever mechanically into the OPEN or CLOSED position When OPEN the lock is constantly open when CLOSED it is a standard lock ...

Страница 15: ...nalling 12V 170mA The fail safe lock is closed when electricity is switched on When electricity is interrupted the lock is opened It contains a built in contact to indicate whether the door is open or closed Power Supply Part No 91378100 PoE injector without cable Part No 91378100E PoE injector with EU cable Part No 91378100US PoE injector with US cable For intercom supply via Ethernet cable where...

Страница 16: ... be controlled Part No 9159013 Departure button Connects the logic input for door unlocking from inside the building Part No 9159012 Magnetic door contact A door installation set for door opening status identification Used for door protection open door or violent door opening detection 9134173 Part No 13 56MHz Mifare RFID card Part No 9134174 13 56MHz Mifare RFID key fob 9134165E Part No 125kHz RF...

Страница 17: ...y 1 output A stand alone IP device which can be controlled from an IP intercom via HTTPcom mands Helps control a device remotely 9137411E Part No External IP relay 4 outputs PoE A stand alone IP device which can be controlled from an IP intercom via HTTP commands Helps control a device remotely Part No 9159014EU US UK 2N 2Wire set of 2 adapters plus EU US UK power supply Converter2N 2Wire helps yo...

Страница 18: ...oor IP67 cover also suitable for exteriors Reads EM4100 and EM4102 cards Part No 9159031 External 13 56MHz Mifare RFID card reader Wiegand Secondary reader for connection to an internal reader Allows for control of card entry from both sides of the door IP68 cover also suitable for exteriors Reads Mifare cards Tip Refer to the local 2N distributor for more accessories and recommendations please ...

Страница 19: ...the manual Safety by this information to prevent persons from injury Always abide Warning by this information to prevent damage to the device Always abide Caution Important information for system functionality Tip Useful information for quick and efficient functionality Note Routines or advice for efficient use of the device ...

Страница 20: ...UNIKACE a s www 2n cz 2 Popis a instalace Here is what you can find in this section 2 1 Before You Start 2 2 Mechanical Installation 2 3 Electric Installation 2 4 Extending Module Connection 2 5 Mounting Completion ...

Страница 21: ...21 2N TELEKOMUNIKACE a s www 2n cz 2 1 Než začnete Product Completeness Check Check your package for completeness before installation 2N Access Unit 2N Access Unit Brief manual ...

Страница 22: ...s in all the mounting types Flush mounting classic bricks incl hollow bricks thermally insulated walls etc What you need for mounting a properly cut hole as instructed in the box package plaster mounting glue mounting foam or mortar as necessary 2N Access Unit flush mounting box and frame 1 module box Part No frame part No 9155014 9155011 2 modules box Part No frame part No 9155015 9155012 ...

Страница 23: ... box Part No frame part No 9155014 9155011 2 modules box Part No frame part No 9155015 9155012 Wall surface mounting concrete and steel structures entry barrier columns interiors etc What you need for mounting 2N Access Unit a proper frame 1 module frame Part No 9155021 2 modules frame Part No 9155022 For uneven surfaces use a backplate for the required count of modules Part Nos 9155061 9155062 ...

Страница 24: ...k which has the security function When the proper mounting instructions are not met water might get in and destroy the electronics It is because the intercom circuits are under continuous voltage and water infiltration causes an electro chemical reaction The manufacturer s warranty shall be void for products damaged in this way Tip Select flush mounting where possible to make your product elegant ...

Страница 25: ... between the values is too great as a result e g of overpressure ventilation separate the intercom using for example the mounting box enclosed and seal the cable passage Surface mounting may cause problems on places exposed to potential vandalism such as public garages etc In this case use steel anchoring elements instead of the dowels and screws included in the delivery The wall mounting surface ...

Страница 26: ...26 2N TELEKOMUNIKACE a s www 2n cz Module Installation 2 2 1 One Module Box 2 2 2 Two Module Box ...

Страница 27: ...27 2N TELEKOMUNIKACE a s www 2n cz 2 2 1 Krabice pro jeden modul Flush mounting classic bricks ...

Страница 28: ...28 2N TELEKOMUNIKACE a s www 2n cz Flush mounting plasterboard ...

Страница 29: ...29 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 30: ...30 2N TELEKOMUNIKACE a s www 2n cz Module flush mounting ...

Страница 31: ...31 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 32: ...32 2N TELEKOMUNIKACE a s www 2n cz Wall surface mounting ...

Страница 33: ...33 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 34: ...34 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 35: ...35 2N TELEKOMUNIKACE a s www 2n cz 2 2 2 Krabice pro dva moduly Flush mounting classic bricks ...

Страница 36: ...36 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 37: ...37 2N TELEKOMUNIKACE a s www 2n cz Flush mounting plasterboard ...

Страница 38: ...38 2N TELEKOMUNIKACE a s www 2n cz Module flush mounting ...

Страница 39: ...39 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 40: ...40 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 41: ...41 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 42: ...42 2N TELEKOMUNIKACE a s www 2n cz Wall surface mounting ...

Страница 43: ...43 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 44: ...44 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 45: ...al base keypad RFID reader etc Use a flat screwdriver to take the upper part out Slide the additional module to the access unit Secure its position with small side wedges and screws Place the assembled modules on the flush mounting box predrilled holes with dowels and pull the cables through the access unit bottom holes Feed the Ethernet cable without the connector from the additional module to th...

Страница 46: ... and the connected modules Access Unit Combined power supply 2N Access Unit can be fed from an external power supply and PoE at the same time In this configuration the maximum power for the connected modules is available LAN Connection 2N Access Unit is connected to the Local Area Network LAN via the UTP STP cable Cat 5e or higher terminated with a terminal board as shown in the figure below As th...

Страница 47: ...12 V DC depending on power supply PoE 10 V adapter power supply voltage minus 2 V up to 400 mA RELAY1 RELAY1 terminals with accessible 30V 1A AC DC NO NC contact 12V 2A External supply terminals for 12 V 2 A DC 3 A for 2N Access Unit multiple modules RESET RESET FACTORY RESET button RJ 45 RJ 45 adapter connector no need to use the PoE RD and TD terminals for this connector Device Restart Press the...

Страница 48: ...nit changing configuration To follow the instructions below get the current IP address Press and hold the RESET button Wait for approx 20 s untilthe red and green LEDs in the right hand bottom LED8 and LED9 in the figure part of the motherboard shine simultaneously above Release the RESET button The device announces the current IP address via the speaker automatically To switch on the DHCP OFF fol...

Страница 49: ...T button Wait untilthe red and green LEDs in the right hand bottom part of the approx 20 s motherboard shine simultaneously Wait until the red LED goes off approx 5 s Wait until the green LED goes off and the red LED comes on again another 5 s Release the RESET button To reset follow the instructions below the factory values Press the RESET button Wait untilthe red and green LEDs in the right hand...

Страница 50: ...ding on power supply PoE 10 V adapter power supply voltage minus 2 V up to 400 mA Warning When you connect a device containing a coil such as a relay or an electromagnetic lock it is necessary to protect the intercom output againstvolta ge peak while switching off the induction load For this way of protection we recommend a 1A 1000V diode e g 1N4007 1N5407 1N5408 connected antiparallel to the devi...

Страница 51: ...1 m 3 m or 5 m for remote module installation Typically it 9155055 helps install an RFID card reader on the opposite side of the wall on which the2N is installed This long cable can only be used once on the bus Access Unit The modules can be combined in each base as follows Module Externally mounted visible module Internally mounted invisible module Infopanel X Klávesnice X 125kHz RFID card reader...

Страница 52: ...that all the modules have sufficient outputs when an external power supply is used When a PoE supply is used the power output is insufficient for all the modules which results in automatic decrease in backlight level active output current supply volume and LED intensity Some modules need a specific power output for their specific activities the I O module e g requires 0 13 W for relay closing not ...

Страница 53: ...r2N Access Unit These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes a 220 mm long interconnecting cable The following RFID cards can be read ISO 14443A Mifare Classic 1k 4k DESFire EV1 Mini Plus S X Ultralight Ul...

Страница 54: ...minals for input in passive active mode 30 V to 30 V DC OFF open or U 1 5 V IN ON short circuit or U 1 5 V IN TAMPER Tamper switch input Part No 9155038 Infopanel Module The Infopanel module is one of the elements Part No 9155030 2N Access Unit and is used for inserting and backlighting of printed information The module contains two bus connectors for2N Access Unit These two connectors are fully i...

Страница 55: ...ed from wi 2N Access Unit th the insulation strength of 500 V DC The module contains two bus connectors for2N Access Unit These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules If this module is the last one on the bus one of the connectors remains unconnected The module package includes an 80 mm long interconnecting cable Co...

Страница 56: ... for enhancing security between the Part No 9159010 access unit and the connected electric lock It significantly enhances security of the connected electric lock as it prevents unlocking by forced opening of i 2N Access Unit s installed Function The Security relayis a device installed between the access unit outside the secured area and an electric lock inside the secured area includes a The Secur...

Страница 57: ... the PB and HeliosIP terminals Press the Departure button to activate the output for 5 seconds Status signalling Green LED Red LED Status flashing off Operational mode on off Activated output flashing flashing Programming mode waiting for initialisation on flashing Error wrong code received Configuration Connect to the properly set access unit security output For the Security relay settings refer ...

Страница 58: ...58 2N TELEKOMUNIKACE a s www 2n cz Connection ...

Страница 59: ...nd tighten the screws The examples in the figures below show incorrectly assembled bases This happens in particular where the screws are tightened first Caution Make sure that the terminals of all the unused connectors are tightened properly to avoid sound vibrations Caution Improper mounting may deteriorate the waterproofness 2N Access Unit Water infiltration may damage the electronic part Make s...

Страница 60: ...60 2N TELEKOMUNIKACE a s www 2n cz ...

Страница 61: ... below while cleaning Do not use aggressive detergents such as abrasives or strong disinfectants Use suitable cleaning agents for glass lens cleaning cleaners for glasses optical devices screens etc Alcohol based cleaners may be applied Clean the device in dry weather in order to make waste water evaporate quickly We recommend you to use cleaning wipes designed for IT electronic items Warning Prev...

Страница 62: ...ding to power supply PoE 10 V adapter source voltage minus 2 V up to 400 mA is part of the Tamper switch 2N Access Unit Inputs passive active mode 30 V to 30 V DC OFF open or U 1 5 V in ON short circuit or U 1 5 V in RFID card reader Frequency 13 56MHz 125kHz Supported 13 56MHz cards card serial number is only read ISO14443A Mifare Classic 1k 4k DESFire EV1 Mini Plus S X SmartMX Ultralight Ultrali...

Страница 63: ...40 C to 70 C Dimensions Wall surface mounting frame 1 module 107 W x 130 H x 28 D mm 2 modules 107 W x 234 H x 28 D mm Flush mounting frame 1 module 130 W x 153 H x 5 D mm 2 modules 130 W x 257 H x 5 D mm Flush mounting box minimum hole dimensions 1 module 108 W x 131 H x 45 D mm 2 modules 108 W x 238 H x 45 D mm Weight Max net weight 2 kg max gross weight 0 5 kg based on configuration Cover ratin...

Страница 64: ...64 2N TELEKOMUNIKACE a s www 2n cz 5 Doplňkové informace Here is what you can find in this section 5 1 Troubleshooting 5 2 Directives Laws and Regulations 5 3 General Instructions and Cautions ...

Страница 65: ...65 2N TELEKOMUNIKACE a s www 2n cz 5 1 Řešení problémů For the most frequently asked questions refer to faq 2n cz ...

Страница 66: ...codesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 Dece...

Страница 67: ...rference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Страница 68: ...sult of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufacturer shall not make any warrant with regard to data loss or damage The manufacturer shall not be liable and responsible for any direct or indirect damage incurred as a result of a use of the product in contrad...

Страница 69: ...ectric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may not...

Страница 70: ...70 2N TELEKOMUNIKACE a s www 2n cz 2N TELEKOMUNIKACE a s Modřanská 621 143 01 Prague 4 Czech Republic Phone 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz xxx ...

Отзывы: