background image

7

 

4. AMP:  

Amplitude control for the random voltage emitted from the 

RND OUT

 

 

If the knob is far left, random voltage will be fully attenuated (0V) 
 
If the knob is far right, random voltage will be full scale (10V) 
 

 
5. RATE CV: 

Control voltage input for the rate of the internal clock 
 
Range 0V 

– 

8V 

 
Control voltage is added to the knob position

 

 

 
6. LED:  

LED that illuminates at the rate of the internal clock when the 

INT/EXT

 toggle is in the 

left position  
 
LED that illuminates when a random gate signal is emitted from the 

GATE OUT

 when 

the 

INT/EXT

 toggle is in the right position

 

 
 
7. GATE OUT:  

Output that will emit gate signals at the rate of the internal clock when the 

INT/EXT

 

toggle is in the left position 
 
Output that will emit random gate signals when the 

INT/EXT

 toggle is in the right 

position

 

 

 
8. RND OUT: 

Output that will emit stepped random voltage at the rate of the internal or external 
clock  
 
Range: 0V 

– 

10V (Max range dependent upon the 

AMP 

control)

 

 
 

 

Содержание Rnd

Страница 1: ...Rnd Random Voltage Generator ...

Страница 2: ... attenuator control provides fine tuning of the random voltage This allows for a musically useful range to be defined In addition random gates are emitted from the gate output with an associated probability control while externally clocked Great for modulation and chaotic rhythmic events Rnd is a universal solution for adding unpredictability to your system ...

Страница 3: ...3 Table of Contents Installation Specifications 4 Rnd 5 General Functions Overview 6 ...

Страница 4: ...tor into the power distribution board of your case keeping in mind that the red band corresponds to negative 12 volts In most systems the negative 12 volt supply line is at the bottom The power cable should be connected to the Rnd with the red band facing the bottom of the module Specifications Format 2 HP Eurorack module Depth 34mm Skiff Friendly Max Current 12V 40mA 12V 16mA ...

Страница 5: ...5 1 2 3 4 5 6 7 8 ...

Страница 6: ...External clock input when the INT EXT toggle is in the right position Threshold 2 5V 3 RATE Internal clock rate control that changes the speed at which random voltage is generated when the INT EXT toggle is in the left position Probability control of random gate signals when the INT EXT toggle is in the right position INT Clock Mode If the knob is far left the internal clock rate will be as slow a...

Страница 7: ... of the internal clock when the INT EXT toggle is in the left position LED that illuminates when a random gate signal is emitted from the GATE OUT when the INT EXT toggle is in the right position 7 GATE OUT Output that will emit gate signals at the rate of the internal clock when the INT EXT toggle is in the left position Output that will emit random gate signals when the INT EXT toggle is in the ...

Отзывы: